Lexicon PCM 81 - REV 2 User Manual page 40

Table of Contents

Advertisement

Basic Operation
The I symbol in the upper left corner of the display indicates that
the currently running effect has an ADJUST knob patch. (When you
display another program or register, this indicator continues to be
displayed.) Turning ADJUST will cause the display to change to
show the patch name and the current value, as well as the Bank,
matrix location and name of the currently running effect. Continue
turning ADJUST to alter the patched parameter's value. You can
create your own ADJUST knob parameter assignments for your
registers. (See Editing, later in this chapter.)
Turn ADJUST to briefly display the Soft Knob assignment.
I
Bank ID, matrix location, and name of currently-running effect.
Note that scrolling through the effects in the Program or Register
banks will not load the effects, but will merely display them (unless
you have specifically turned on the Auto Load function in Control
Mode). Displayed effect names will be preceded by an ✱
indicating that they can be loaded by pressing Load/✱. (The
Load/✱ LED will light to indicate that the load function is available.)
To find out at any time what the currently running effect is, press
and hold Program Banks or Register Banks. An Info message will be
displayed providing the name bank and matrix location of the
currently running effect.
2-18
To select an effect stored in a register, press Register Banks. If you
have registers stored on a memory card, and have the card
inserted, pressing Register Banks repeatedly will cycle through all of
your stored bank selections. Simultaneously press Register Banks
along with either Up or Down to backstep. Turn SELECT to scroll
through all of the effects in the bank. As in Program Banks mode,
an asterisk in front of the effect name indicates that the displayed
effect is not loaded. Press Register Banks to reselect the last
displayed effect in another bank. Unused registers are indicated by
the message "available" on the display. Press Load/✱ to load the
displayed effect.
Register Bank ID
Current Soft Knob
The PCM 81's internal register is labeled R;
parameter setting.
register banks created on memory cards
Turn ADJUST to
will be labeled C0, C1, C2, etc.
alter this value.
The organization of programs in the six program banks and
descriptions of the 300 preset programs are given in Chapter 3.
The name you assign to a
Matrix Location
stored effect will appear here.
"available" indicates that no
effect has been stored at this
location.
Lexicon

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm 81

Table of Contents