Frigidaire BGGF3042KFT Installation Instructions Manual
Frigidaire BGGF3042KFT Installation Instructions Manual

Frigidaire BGGF3042KFT Installation Instructions Manual

Freestanding gas range

Advertisement

INSTALLATION
AND SERVICE
MUST BE
PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE. READ AND SAVE THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
• ALL RANGES
CAN TiP
• INJURYTO
PERSONS
COULD
RESULT
• iNSTALL
ANTI=TIP
DEVICE
PACKED
WiTH
RANGE
• SEE iNSTALLATiON
INSTRUCTIONS
if the
information
in this
manual
is not followed
exactly,
a fire or
explosion
may result
causing
property
damage,
personal
injury or death.
FOR YOUR SAFETY:
m
Do not store or use gasoline
or other
flammable
vapors
and liquids in the
vicinityofthis
oranyotherappliance.
WHAT TO DO iF YOU SMELL
GAS:
= Do not try to light any appliance.
= Do not touch
any electrical
switch;
do
not
use
any
phone
in your
building.
= immediately
call your
gas supplier
from
a neighbor's
phone.
Follow
the gas supplier's
instructions.
= if you
cannot
reach
your
gas
supplier,
call the fire department.
installation
and
service
must
be
performed
by a qualified
installer,
service
agency
or the gas supplier.
Provide
proper fuel type
Before proceeding: Your range is factory preset to
operate on natural gas. If L.P. conversion is needed,
contact your local L.P. Gas provider for assistance.
The L.P. conversion kit may be located on the lower rear
back panel of the range. If no L.P. kit is provided, contact
your product dealer to obtain the correct L.P. conversion kit.
__
Refer to your serial plate
for applicable agency
certifications
important
notes to the installer
Read all instructions contained in these installation
instructions before installing range.
Remove all packing material from the oven
compartments
before connecting the gas and
electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
important
notes to the consumer
Keep these instructions with your Use & Care Guide
for future reference.
Be sure your range is installed and grounded properly
by a qualified installer or service technician.
Special instructions for appliances installed in the State of
Massachusetts:
This appliance can only be installed in the State of
Massachusetts by a Massachusetts licensed plumber or
gas fitter. When using a flexible gas connector, it must not
exceed 3 feet (36 inches) in length. A "T" handle type
manual gas valve must be installed in the gas supply line to
this appliance.
IMPORTANT
SAFETY INSTRUCTIONS
Installation of this range must conform with local codes or,
in the absence of local codes, with the National Fuel Gas
Code ANSI Z223. l--latest
edition when installed in the
United States.
When installed in a manufactured (mobile) home,
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
[formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or, when
such standard is not applicable, the Standard for
Manufactured Home Installations, ANSI/NCSBCS A225.1,
or with local codes.
This range has been design certified by CSA International.
As with any appliance using gas and generating heat, there
are certain safety precautions you should follow. You will
find them in the Use & Care Guide, read it carefully.
p/n 316903000 (1004)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BGGF3042KFT and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Notes to the Installer
Installer Responsibilities
Read all instructions, remove packing, observe codes, leave with consumer.
Important Notes to the Consumer
Consumer Guidance
Keep instructions, ensure proper installation & grounding.
Important Safety Instructions
Massachusetts Installation Requirements
Licensed installer, max 3ft flexible gas connector, "T" handle valve required.
General Safety and Code Compliance
Conforms to local codes/NFGC; mobile home standards; CSA certification; follow Use & Care Guide precautions.
Important Safety Instructions
Electrical Grounding and Extension Cords
Proper grounding per NEC, extension cord use discouraged.
Floor and Wall Clearance Requirements
Heat resistance of floor/wall coverings, no carpeting without pad.
Combustion Air and Hood Compatibility
Do not obstruct air flow; specific hood restrictions.
Operation During Power Failures
Warning about electric ignition, using matches to light burners.
General Usage and Storage Warnings
Supervise children, avoid door leaning, no storage above range, no room heating, no flammable liquids.
Tools and Materials
Tools for Installation
Wrenches, screwdrivers, drill, level, pipe wrenches.
Materials for Gas Supply
Pipe joint sealant, shut-off valve, flexible conduit, flare union adapters.
Appliance Supplied Materials
Anti-tip template, anti-tip bracket with screws.
Installation Location and Clearances
Installation with Cabinets
Minimum dimensions for side, top, and depth clearances.
Installation Considerations
Do not seal to cabinets, avoid pinching cord, seal wall openings.
Installation Beside Wall
Minimum distance to combustible wall based on burner BTU.
Install Anti-Tip Bracket
Anti-tip Bracket Installation
Locate bracket using template, drill pilot holes, fasten bracket securely.
Range Positioning and Securing
Level range, slide back, check bracket engagement, test tilt.
Gas Supply Connection
Adequate Gas Supply Requirements
Operation at elevation, manifold pressure, inlet pressure, gas supply line size.
Connecting the Gas Supply
Use sealant, install shut-off valve, connect adapter to regulator, stabilize regulator.
Sealing Wall Openings
Seal openings in wall and floor after gas supply installation.
Gas Supply Connection Details
Tightening Gas Fittings
Use correct torque, stabilize adapters, tighten fittings.
Checking Manifold Gas Pressure
Warning on leak checks, pressure testing procedures, manifold pressure values.
Gas Leak Detection
Use liquid leak detector at all joints and conduits.
Electrical Connection and Burner Cap Placement
Electrical Connection Requirements
Dedicated, grounded circuit; extension cord precautions.
Grounding Instructions
Appliance cord has 3-prong plug; ensure receptacle is properly grounded.
Burner Cap and Grate Placement
Ensure caps/grates are properly installed and in correct locations.
Burner Cap Fit Verification
Check cap size matches head, level fit, snug seating, side-to-side test.
Ignition and Burner Adjustment Checks
Surface Burner Ignition Test
Test ignition by turning knob to LITE, check for spark and flame within 4 seconds.
Surface Burner Low Flame Adjustment
Adjust flame size for stable low setting, counterclockwise to increase.
Oven Burner Ignition Test
Test bake/broil ignition, check for proper flame, cycle time.
Oven Burner and Leveling Adjustments
Lower Oven Flame Adjustment
Adjust air shutter for 1-inch blue flame, loosen lock screw, reposition shutter.
Upper Oven Flame Adjustment
Adjust air shutter for 1-inch blue flame for broil, loosen lock screw, reposition shutter.
Range Leveling Procedure
Level horizontally on rack, check diagonally, adjust legs or use shims.