enware ENM5072A-205 Installation And Maintenance Instructions Manual

Touch-free wall sensor tap- on/off demand sensor, on / off demand stainless steel wall sensor panel with 205mm/250mm spout

Advertisement

Quick Links

ENWARE TOUCH-FREE WALL SENSOR TAP
- ON/OFF DEMAND SENSOR
Installation and Maintenance Instructions
ENM5072A-205
EMM5072A-250
I00316_May20
Call 1300 369 273
www.enware.com.au
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: 02 8536 4000 info
enware.com.au
@
On / Off Demand Stainless Steel Wall Sensor Panel
With 205mm Spout
On / Off Demand Stainless Steel Wall Sensor Panel
With 250mm Spout

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENM5072A-205 and is the answer not in the manual?

Questions and answers

Summary of Contents for enware ENM5072A-205

  • Page 1 ENWARE TOUCH-FREE WALL SENSOR TAP - ON/OFF DEMAND SENSOR Installation and Maintenance Instructions ENM5072A-205 On / Off Demand Stainless Steel Wall Sensor Panel With 205mm Spout EMM5072A-250 On / Off Demand Stainless Steel Wall Sensor Panel With 250mm Spout I00316_May20 Call 1300 369 273 www.enware.com.au...
  • Page 2: Product Description

    Enware Touch-Free Wall Sensor Tap is a sensor operated, hands-free tap that is installed onto walls above sinks, basins or wash troughs. It operates by sensing a hand in front of the sensor unit. Once the sensor is activated, the valve will remain open and water will flow until the hand is again placed in front of the sensor, closing the solenoid valve.
  • Page 3: Technical Data

    The optional settings are available at the time of ordering. Contact Enware for more details. installation compliance *Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
  • Page 4: Location Of Sensor

    SET-OUT HEIGHTS Suggested heights from finished floor: Spout 1050mm outlet 1120mm to point of water discharge (Australasian Health Facility Guidelines) Top of 850mm basin 865mm (Australasian Health Facility Guide- lines) 800 - 830mm (Reference: AS1428.1-2009) Call 1300 369 273 www.enware.com.au...
  • Page 5: Water Supply Temperature

    WARNING: Do not cut the wires or extend Thermostatic Mixing Valve be used to the existing cables without using the provide pre-mixed water to the valve. correct lead extension from Enware, as this will void warranty. www.enware.com.au Call 1300 369 273...
  • Page 6: Installation In-Wall

    SEE IMAGE 01 Call 1300 369 273 www.enware.com.au...
  • Page 7 120mm high rectangular hole, and at least 65mm WALL CUT OUT deep to allow for installation of bracket. Sensor ENM5071A ENM5072A cable to come through the top, bottom, or back of SENSOR BRACKET sensor inside wall. SEE IMAGE 05 IMAGE 05 www.enware.com.au Call 1300 369 273...
  • Page 8 3 metre lead from the sensor to the solenoid. Additional lead lengths up to 15 metres 4.5m can be accommodated with extension cables (available separately from Enware). SEE IMAGE 06 TRANSFORMER CABLE WARNING: Do not cut the electrical cable of IMAGE 06 the sensor tap, or alter the product in any way to suit installation.
  • Page 9 Sensor components are fragile and sensitive. Do not force the sensor plate to fit onto wall, See Operating Instructions overpage. or attempt to disassemble sensor components, as this could result in damage to sensor and would void warranty. www.enware.com.au Call 1300 369 273...
  • Page 10: To Turn Off

    When hand is within sensor range, sensor responds with a Red LED light in the sensor lens. *Longer flow time settings are available – contact Enware for more information. Hand too close to sensor Wave quickly in front of sensor...
  • Page 11: Troubleshooting

    Replace solenoid valve Tap/ water turns off slowly Debris in solenoid valve Take solenoid apart and clean diaphragm. Refer to Solenoid Maintenance section. Solenoid diaphragm is Replace solenoid diaphragm damaged or solenoid. Refer to Solenoid Maintenance section. www.enware.com.au Call 1300 369 273...
  • Page 12: Spare Parts

    PART ENWARE PRODUCT CODE Sensor – On / Off Demand ENMS133A (Stainless steel plate, sensor connector cable) Solenoid 1/2” – DC 24v (includes DC solenoid 1/2”, WMS8200 2x 1/2” nipples) Solenoid Service Kit - DC (includes diaphragm, piston and spring to suit DC WMS8302 solenoid 1/2”)
  • Page 13: Service And Maintenance

    Take note of the order of parts assembled. SEE IMAGES 10, 11 4. Check seat and diaphragm for debris or any damage. SEE IMAGE 12 IMAGE 12 www.enware.com.au Call 1300 369 273...
  • Page 14 DIRECTION OF FLOW 11. Finally place the black coil body back over the core tube, and tighten the hex nut back up. IMAGE 15 DIRECTION OF FLOW IMAGE 16 DIRECTION OF FLOW IMAGE 17 Call 1300 369 273 www.enware.com.au...
  • Page 15: Replacing The Sensor

    CLEANING behind the plate along the top and Enware Product should be cleaned with a soft damp side edges. Ensure that the plate is cloth using only mild liquid detergent or soap and thoroughly sealed to the wall and water.
  • Page 16: Making A Claim

    Form available on website www.enware.com.au. All notifications and accompanying forms must be sent to other conditions us marked for the attention of the Enware Australia Pty Limited, 9 Endeavour Road, Caringbah NSW 2229. We Except as provided or referred to in this document, we...

This manual is also suitable for:

Emm5072a-250

Table of Contents