Quality Assurance 1. Warranty conditions The free service during the warranty period is only valid under normal use and maintenance according to the user manual, and all man-made failures or damages are not covered by the warranty. Users please keep the purchase invoice and user manual well, so that you can get satisfactory after-sales service in time.
8) Failure or damage caused by use outside the applicable occasion; 9) Damage caused by force majeure, etc.; 10) Consumable and wearing parts ( such as pump pipes, connecting pipes, etc.); 11) The warranty period has expired. 1.Product Description 1.1 Introduction M1 smart peristaltic pump is a kind of smart peristaltic pump used in the laboratory.
1.4 Component names 1. Color LCD display 2. Pump head 3. Button Menu: Click to enter the menu, or return to the previous menu from the submenu -: Click to decrease the amount or the menu is up Setting: Click to enter the setting menu, or return to the previous menu after the setting takes ...
2. Product Installation 3.Touch screen control 3.1 Quantitative Mode Quantitative mode is to set a certain quantity, the pump will run according to the certain quantity, and it will stop automatically after running. The certain quantity can be time or volume. If you want to run this quantification cycle, you can set a target number of times and the interval time between each run of quantification.
Page 7
1. Running direction: the running direction of the pump, switch the direction through the direction button 2. Start and stop: control the start and stop of the pump, by controlling the inner diameter of the start and stop 3. Speed percentage: the percentage of pump running speed, adjusted by the knob on the back 4.
1. Setting menu title: When the cursor is on this title, press the setting button on the device to return to the previous menu 2. Modify Quantitative: Click to enter the Modify Quantitative menu, where you can choose whether to add according to time or volume 3.
3.3 System menu Enter the system menu by pressing the menu button, in the system menu, select continuous mode or quantitative mode, and return to the working mode 1. Continuous mode, click the setting button to enter continuous mode 2. Quantitative mode, click to set to enter quantitative mode 3.
After entering the calibration process, first empty the air in the tube and fill it with liquid, press the + button to switch the cursor to the start emptying function, press the setting button to start emptying, wait for the liquid to fill the tube, press the setting button again to stop, and automatically Enter the calibration function interface.
and - buttons to switch between different options, press the setting button to take effect, and press the menu button to return to the upper menu. 1. Power-on status menu title: Press the SET button to return to the previous menu 2.
Address: Building 4, No. 79, Xiangjing Road, Songjiang District, Shanghai Website: www.kamoer.com Kamoer, Kamoer words and icons are registered trademarks of Kamoer Fluid Tech (Shanghai) Co., Ltd. The company reserves the right to improve and change product appearance and technical specifications without prior notice.