Miles Industries Valor 739-72NGK Installation Instructions Manual

Natural gas conversion kit use with with model 739-72 heater only

Advertisement

Quick Links

Once converted to NG, this appliance is certifi ed for
use from 0–4500 feet. For altitudes above 4500 feet,
see local codes.
Kit Contents
1 Pilot injector (marked 35)
1 Burner
1 Injector (marked 750)
1 Set of conversion labels
1 Set of air shutters
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module &
pilot shield
Small (jewelers size) fl at blade screwdriver, to set
pressure
Small fl at blade screwdriver, to release pressure tap
on valve
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
Manometer, to set manifold at the valve
Rating
Maximum 26,000 Btu/hr
Minimum 6,500 Btu/hr
General notes regarding conversion
The conversion may be done before or after the
appliance is installed into the cavity. However, the
gas must be connected in order to set the manifold
pressure.
4002453C-01
L
EGEND
N
Natural Gas Conversion Kit
739-72NGK
Use with with Valor Model 739-72 Heater ONLY
Installation Instructions
© 2014, Miles Industries Ltd. All rights reserved.
G3
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Valor 739-72NGK and is the answer not in the manual?

Questions and answers

Summary of Contents for Miles Industries Valor 739-72NGK

  • Page 1 General notes regarding conversion The conversion may be done before or after the appliance is installed into the cavity. However, the gas must be connected in order to set the manifold pressure. 4002453C-01 © 2014, Miles Industries Ltd. All rights reserved.
  • Page 2 Conversion Procedure 7. Detach the two burner support brackets from the burner by removing two nuts, using a 5/16” (8 mm) 1. If the fi replace is already installed, remove the wrench. window, ceramic logs and brick liners. 2. Disconnect the gas inlet pipe from the inlet elbow fi...
  • Page 3 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel.
  • Page 4: Directives D'installation

    Cependant, le gaz doit être branché pour régler la pression d’admission. Brûleur gaz propane : marqué LPG, une rangée de fentes entre deux rangées de petits trous © 2014, Miles Industries Ltd. Tous droits réservés...
  • Page 5 Procédure de conversion 7. Détachez les 2 supports de brûleur du brûleur en enlevant 2 boulons à l’aide d’une clé de 5/16” 1. Si le poêle est déjà installé, enlevez la devanture, la (8 mm). fenêtre, les bûches et panneaux de céramique. 2.
  • Page 6 Parce que nous favorisons une politique de développement continu, certains détails de la présente publication peuvent varier. Conçue et fabriquée par / pour Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tél. 604-984-3496 Téléc. 604-984-0246...

This manual is also suitable for:

Valor legend g3