Page 1
MANUAL COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us concerning this unit, it will help us to respond to your needs faster.
TABLE OF CONTENTS SAFETY INFORMATION SAVE THESE INSTRUCTIONS SPECIFICATIONS GENERATOR ENGINE INTRODUCTION TESTING POLICY Rated output of generator is based on engineering tests of typical units, and is subject to, and limited by, the temperature, altitude, fuel, and other conditions specified by the manufacturer of applicable engines. INTENDED USES RESTRICTED USES UNIT CAPABILITIES...
SAFETY INFORMATION WARNING: FIRE HAZARD Gasoline and other fuels present a hazard CALIFORNIA PROPOSITION 65 of possible explosion and/or fire. A. Do not refuel when the engine is running or This product contains crude oil, gasoline, diesel fuel hot. and other petroleum products, Antifreeze to which B.
Read and understand all instructions in the manual before starting and operating the generator. USING THIS MANUAL Congratulations on your choice of a WINCO generator. You have selected a high-quality, precision-engineered generator designed and tested to give you years of satisfactory service.
INTRODUCTION TESTING POLICY Before any generator is shipped from the factory, it is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current, and frequency are carefully checked. Rated output of generator is based on engineering tests of typical units, and is subject to, and limited by, the temperature, altitude, fuel, and other conditions specified by the manufacturer of applicable engines.
UNIT CAPABILITIES GENERATOR CONNECTIONS WL22000VE: 120 Volt and 240 Volt receptacles are provided for connection to various loads. The following diagram represents this 19,000 watt (rated output) generator. A & B represent the 120 volt output legs of this generator. Up to 9500 watts at 120 volts (79 Amps) can be drawn from the receptacles attached to either A or B output legs.
If any damage is noted, it is always easiest to shutdown system is designed to prevent severe damage refuse the shipment and let WINCO take care of the freight caused by an insufficient amount of oil in the crankcase.
BATTERY INSTALLATION This engine generator set is shipped with a bungee cord for installation of the customer supplied battery in the unit’s WARNING battery tray. 1. Never smoke when near batteries. 2. Do not cause a If you intend to use the unit’s electric start system, you will flame or spark in the battery area.
INITIAL START UP STARTING HINTS 1. COLD WEATHER WARNING: PERSONAL INJURY A. Use the proper oil for the temperature expected. B. Use fresh winter grade fuel. Winter grade gasoline is Improper maintenance, or failure to fix any problems during blended to improve starting. Do not use summer grade operation, could cause equipment damage and possible gasoline.
DO NOT operate this unit inside a home Your WINCO portable generator ships with a bonded or garage, near vents or windows, or anywhere neutral. You can safely use this generator without external carbon monoxide gas could accumulate.
Page 12
must be installed. The transfer switch must be compatible with GFCI protected generators. WINCO recommends Reliance manual transfer switches. The transfer switch prevents damage to the generator and the other circuit components if main line power is restored while the...
For normal usage, the speed setting should The WINCO YourGen meter allows you to see useful not be changed. If the generator is being run continuously information about your generator from the front panel...
Page 14
120 Volt and 120/240 Volt receptacles are provided for spark plug wire and then open the receptacle panel. Locate connection to various loads. the backside of the YourGen meter. Gently pry the back plate off using the slot located on top. The following diagram represents this 19,000 watt (rated output) generator.
and the retainer Outdoor temperatures determine the proper oil viscosity for 3. Remove the air filter the engines. Winco recommends our 5W-30 fully synthetic oil to give you excellent protection in cold temperatures 4. Remove the pre-cleaner while maintaining excellent performance in warmer weather from the air filter...
SPARK PLUG Replace annually or every 300 hours of operation. Always replace with the same spark plug that came in the engine and check gap before installing. Spark plug gap is 0.030”. Poor spark will also occur if spark plug wire does not fit firmly on spark plug.
GENERATOR CARE AVR WIRING AUTOMATIC VOLTAGE REGULATOR Proper care and maintenance of the generator is necessary to ensure a long trouble free life. The following is a list of connections on the AVR. These EXERCISING THE GENERATOR have been factory set and other than voltage adjustment, should never be changed.
2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your equipment leading to the failure of the evaporative emission control system.
Air cooled units purchased for stock have 1 year to be sold. The warranty to the original retail customer commences on the date of sale of the product to them. All liquid cooled units have 180 days from the Winco invoice to submit a start up date. If no startup form is submitted, then warranty period starts on the Winco invoice date unit was sold.
Note 2: 3rd Year warranty coverage is parts only/no labor. Note 3: Round trip mileage is limited to 200 miles per trip and a total of 2 trips per repair unless authorized in writing by the WINCO Service Dept.
Page 24
225 S. CORDOVA AVE • LE CENTER, MN 56057 Sales: 507-357-6821• sales@wincogen.com Service: 507-357-6831 • service@wincogen.com www.wincogen.com OPM-140/H...