Page 1
READ AND SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS Model:AC40252 Kendal Lighting(BC) inc. #110,6780 Denett Place Delta,BC V4G 1N4 Canada Tel:(604)952-5510 Fax:(604)952-5513 CETL LISTED MODEL: 52HZ-1088L Weight of Fan:4.4KGS...
1. TOOLS AND MATERIALS REQUIRED • Philips screw driver • Blade screw driver • Step ladder • Wire cutters 2. PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: Blade set(3) Hanger bracket Canopy Canopy cover Coupling cover 5”...
3.SAFETY RULES 1. To reduce the risk of electric shock, insure 7. For fans with manual reverse, do not electricity has been turned off at the circuit operate reversing switch while fan blades breaker or fuse box before beginning. are in motion. Fan must be turned off and blades stopped before reversing blade direction.
4. MOUNTING OPTIONS If there isn't an existing CUL listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Outlet box Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials.
5. ATTACHING THE FAN BLADES Blade screws Attach the blade to the fan motor assembly Blade using blade screws. Attach the other blades to the fan motor assembly. (Fig.5) Fan motor Note: Please follow the instruction manual and assembly make sure to use correct screws during the installation process.
7. HANGING THE FAN REMEMBER to turn off the power. Follow the CUL Listed electrial steps below to hang your fan properly : Step 1. Pass the 120-volt supply wires through Hanger bracket Flat washer the center in the ceiling hanger bracket as Lock washers shown in (Fig.
Page 7
Step 8. 1.Install the hanger ball back to downrod using the reverse steps from (Step 3) (Fig.13) Figure 13a 2.Reinstall the safety cable coupler onto the safety cable using the reverse steps from (Step 4) (Fig.13 a) Figure 13 Step 9. Place the downrod ball into the hanger bracket socket.
8. MAKE THE ELECTRIC CONNECTIONS Hanger bracket WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. Step 1. (Fig. 15) Insert the receiver into the hanger bracket with the flat side of the receiver Receiver facing the ceiling.
9. INSTALLATION OF SAFETY SUPPORT A safety cable is provided to prevent the fan from falling. Secure the safety cable to the ceiling joist with screw and washer, as Flat washer Safety cable illustrated in (Fig.17) Lock washer Screw Hanger bracket Figure 17 10.
11. INSTALLING THE BATTERY Remove the back cover on the transmitter and install two 1.5V batteries included with the remote control. (Fig. 20) 12. LEARNING PROCESS Figure 20 The receiver and transmitter are already prepaired with each other in the production process, and if you encounter a situation that you cannot control, you can pair by the following actions.
14. OPERATING YOUR TRANSMITTER A. Press the " " button to turn off the fan (*this button is only used to turn off the fan, it cannot start the fan, and it will not turn off the LED lamp Fig.23) B.
15. CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 1. Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling). 2.
16. TROUBLESHOOTING Problem Solution Fan will not start. 1. Check circuit fuses or breakers. 2. Check line wire connections to the fan . CAUTION: Make sure main power is off. Fan sounds noisy. 1. Make sure all motor housing screws are snug. 2.
Need help?
Do you have a question about the AC40252 and is the answer not in the manual?
Questions and answers