DINKO Instruments D-25VT - CFV-4r Instruction Manual

Variable flow peristaltic pumps with timer

Advertisement

Quick Links

VARIABLE FLOW PERISTALTIC PUMPS WITH TIMER
Model D-25VT - CFV-4r
Code 1.9736.80
s
INSTRUCTION MANUAL
April 2025
Marked
c/ Encarnació, 123 -125. Tel. +34 93 284 69 62. Fax +34 93 210 43 07
e-mail:
dinter@dinko.es
www.dinko.es
08024 - Barcelona
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D-25VT - CFV-4r and is the answer not in the manual?

Questions and answers

Summary of Contents for DINKO Instruments D-25VT - CFV-4r

  • Page 1 VARIABLE FLOW PERISTALTIC PUMPS WITH TIMER Model D-25VT - CFV-4r Code 1.9736.80 INSTRUCTION MANUAL April 2025 Marked c/ Encarnació, 123 -125. Tel. +34 93 284 69 62. Fax +34 93 210 43 07 e-mail: dinter@dinko.es www.dinko.es 08024 - Barcelona...
  • Page 2: Table Of Contents

    INDEX Page GENERAL INTRODUCTION ······································································ 3 PACKING LIST ······················································································· 3 RECEPTION ··························································································· 4 DESCRIPTION ························································································ 5 SPECIFICATIONS ··················································································· 7 START-UP ····························································································· 7 DIGITAL TIMER ······················································································ 9 ACCESSORIES ····················································································· 15 CHANGING TUBE ·················································································· 17 ORDER INFORMATION ·········································································· 19 CHANGING FUSES ················································································ 19 PROBLEM SOLVING ··············································································...
  • Page 3: 1- General Introduction

    1- GENERAL INTRODUCTION Peristaltic pumps pump all kinds of liquid substances without coming into contact with mechanical elements as in other pumps. They are easy to use with minimal maintenance. The pumped substance is propelled into an elastic tube by the vacuum generated by rotors that successively press and release the surface of the tube.
  • Page 4: 3- Reception

    3- RECEPTION To ensure proper reception and use of the device, and user safety, we recommend reading this manual carefully before unpacking the device and subsequent use, especially the following points: 3.1- THE MANUAL This manual must be kept at all times within reach of the user of the equipment. 3.2- UNPACKING Carefully unpack the appliance, checking that the contents match the list of packaging.
  • Page 5: 4- Description

    4- DESCRIPTION The D-25VT peristaltic pumps in this manual are fitted with the CFV-4r head which allows easy access to the tube for removal when it needs to be replaced. The head supports various tube sizes which, combined with speed regulation, gives a wide variety of flows, as can be seen in the flow rate guide table.
  • Page 6: Front Panel

    CFV-4r multiple coupling head The pump mounts one head as shown above and can mount up to a total of four heads in its place. Two heads are shown attached below. The pump heads of a coupled assembly must be assembled and configured at the factory as such. Remove the head and send it to the factory to configure the required head assembly with a maximum of 4 heads.
  • Page 7: Rear Panel

    4-3 REAR PANEL Figure b 7- Main ON/OFF switch 8- Fuse box 9- Take food 10- Timing mode selector 11- Voltage-free pedal input, external relay. 12- Fan. 5- SPECIFICATIONS 5.1 DIMENSIONS Pump: 340 x 280 x 180. Weight 7 Kg Operation: between 100 and 240V.
  • Page 8 6.2- Set the engine rotation direction selector to the “0” position (Figure a (3)). Check the position of the IO selector (Figure b (10)). Select the speed using the percentage numeric indicator buttons. With a 100% reproducibility, a speed range of 0 to 99% of the speed is available maximum with an accuracy of 1% (Figure a (2)).
  • Page 9: 7- Digital Timer

    7-TIMER When the device is connected, the timer turns on and remains on standby. To start it, press the ▲ (6) key. 1- OUT Open/closed contact indicator - red light 2- Measured time (red) 3 - Scheduled time (green) 4 - Units of time (hour-minute-second) H/M/S-pilot green. button 6- Increment button 7- Scroll button...
  • Page 10 Menu sequence – Factory programming Pressing ▲ selects i nt Select time of 1 mS answer. 20ms Press Pressing ▲ selects Select the menu you want n (N Mode) F (F Mode) Description of the different modes in the Modes of use section C (C Mode) r R Mode) Press Pressing ▲...
  • Page 11 7-2 Selection of running and stopping time. The timer has 2 programming times t.oFF and t.on that indicate the status of the timer contacts. t.oFF will always be the first to count and then t.on will start . N, F modes we can only program the t.oFF, however in R mode , we must configure the t.oFF and the t.on.
  • Page 12 7.3 Modes of use The pump has a timing mode selector with two positions, O and I, on the back . (Figure b (10)). In position O , when the timer is started (pressing the ▲ key on the timer will start counting the programmed times), the head will run for the time programmed as t.oFF.
  • Page 13 When you want to program a single delayed dosage; that is, when the timer is activated, it will count the programmed time with the head stopped, and when that time is up, the head will start working until the equipment is stopped. Programming: Timing mode selector in position I (figure b (10)).
  • Page 14 7.3.c- R Mode Asymmetric cyclic mode, in which an operating time and a stopping time are programmed to be repeated indefinitely. This working mode is used for: When we want to perform repetitive dosing of a specific volume, with a pause between each dosing to transfer the rubber to another container for another dosing.
  • Page 15: 8- Accessories

    8- ACCESSORIES 8.1 Scales for flow and dosage calibration To measure the dosed quantity in the calibration process of peristaltic pumps, it is very effective to use a precision scale with digital reading. If the liquid to be pumped has a density of "1," there will be no difference between grams and milliliters.
  • Page 16 CONNECTORS FOR PERISTALTIC TUBES 8.5 Straight connectors for splicing / equal ends, polypropylene Straight connector for 1.6 mm inner diameter tubes. Code 1.0080.15 Straight connector for 3.2 mm inner diameter tubes. Code 1.0080.18 Straight connector for 4.8 mm inner diameter tubes. Code 1.0080.05 Straight connector for 6.4/8 mm inner diameter tubes.
  • Page 17: 9- Changing Tube

    9- CHANGING TUBE Each pump is supplied with a set of medical/food grade silicone peristaltic tubing that meets FDA and USP standards, autoclavable at 120°C, with a peristaltic usage range of up to 80°C and medium life. The peristaltic quality of the tubes or rubbers consists of their ability to quickly recover their roundness once the rollers of the peristaltic head of the pump have compressed them to generate the circulation of liquids inside.
  • Page 18 9.1 AVAILABLE TUBES PHARMA Autoclavable multiple times. Sterilizable by ETO and Gamma . Medical-food grade, class VI USP, 21CFR 177.2600 and FDA. Non-hemolytic. Excellent resistance to chemicals. ISO 10993. Low permeability and good abrasion resistance. Long duration. Use temperature, -51ºC to 132ºC Beige color.
  • Page 19: 10- Order Information

    10- ORDERING INFORMATION Peristaltic pump head CFV-4r. For 1.6 mm wall tubing. Model D-25VT. Code: 1.9736.80 11- CHANGING FUSES The fuse box is part of the power supply base located on the rear of the pump. See figure. Main switch Fuse box Power base Pry the fuse box between the center of the fuse box and the top of the power supply base with a...
  • Page 20: 13- Maintenance - Spare Parts

    Before any examination or repair of the appliance, it is necessary to disconnect the power supply. Every initiative must be carried out by qualified personnel to avoid major problems. Entrust your device to a technical service authorized by DINKO Instruments. The engine and its block do not require lubrication so they do not have maintenance.
  • Page 21: 14- Warranty

    14- WARRANTY DURATION: The warranty is valid for a period of one year from the date the appliance is put into operation, provided the warranty card is returned to us within eight days of its commissioning. Without this condition, the warranty will not be valid. SCOPE OF WARRANTY: The warranty covers manufacturing and material defects for an average work week of 40 hours.
  • Page 22: 15- Ec Declaration

    15-DECLARATION OF CONFORMITY “CE” DINTER SA / DINKO Instruments c/ Encarnació, 123-125 / 08024 - Barcelona Declares that the articles mentioned in the attached list, to which this declaration refers, comply with the essential safety requirements of the applicable European Directive: - Low Voltage Directive, Directive 2014/35/EEC of 26 February 2014 and applicable since 2016 in accordance with the recommendations of the LVD Directive.
  • Page 23: 16- Other Dinko Devices

    OTHER DINKO APPLIANCES -Colorimeters - Conductimeters - Dosing Pumps - Extractor for meat analysis - Grinders-Homogenizers - Heating Plates - Kits for water analysis - Magnetic Stirrers - Metal block heaters - Microscopes - Nephelometers - Orbital Shakers - Oximeters - Peristaltic Pumps - pH meters - Photometers...