ACS Hydrocont HP4SC Operating Instructions Manual

Hydrostatic filling level transmitter with capacitive ceramic pressure measuring sensor, temperature sensor and conductivity sensor
Hide thumbs Also See for Hydrocont HP4SC:

Advertisement

Quick Links

OPERATING MANUAL - BA08.24
Hydrocont HP4SC
Hydrostatic filling level transmitter
with capacitive ceramic pressure measuring sensor,
temperature sensor and conductivity sensor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hydrocont HP4SC and is the answer not in the manual?

Questions and answers

Summary of Contents for ACS Hydrocont HP4SC

  • Page 1 OPERATING MANUAL - BA08.24 Hydrocont HP4SC Hydrostatic filling level transmitter with capacitive ceramic pressure measuring sensor, temperature sensor and conductivity sensor...
  • Page 2: Table Of Contents

    Revision ................................... 19 Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 3: About This Document

    [04-5] Exemplary notice to a type variant (>> chapter Product description - Product code) 1.3. Other documents Besides this document the following material can be found on the Internet at www.acs-controlsystem.com: • EU Declaration of Conformity (current version) • Manufacturer declarations •...
  • Page 4: Safety Instructions

    The associated EU-Declaration of Conformity can be ordered or downloaded from the homepage. Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 5: Product Description

    1 = L+ / Cio = FSK (5) Safety notes 2 = nc 3 = L- / Io (6) Approvals 4 = nc 84307 Eggenfelden / Germany www.acs-controlsystem.com ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 6: Product Code

    Differing versions are normally marked by the character Y at the product code. Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 7: Dimensions

    3.5. Dimensions Dimensions in mm Electrical connection 14-K Electrical connection 14-H Electrical connection 14-0 Confection stranded wires Confection Hydrolog HLF4 Without confection ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 8: Packaging, Transport, Storage

    IP65/IP67 G 1,5" Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 9: Field Enclosure

    Data logger with remote transmission LTE-M1, LTE-NB2, EGPRS / Bluetooth® 5.2 161000377 battery operation, In: 0/4…20mA/0..10V/RS485 Modbus-RTU/Digital-In field installation isHRT USB Interface converter FSK - USB 611000595 Waveshare 15817 Interface converter RS485 - USB 611000588 ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 10: Installation

    Let the system cool down sufficiently before installing the device. There is a risk of dangerous and hot media escaping. Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 11: Electrical Connection

    RL ≤ (Us - 9V) / 22,2mA The device must be grounded, preferred by the metallic process connection, alternatively by the cable shield. Install cable separated from power leading cables. ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 12: Analogue Output Io

    A(+) B(-) YE/GN Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 13: Connection Cable

    The device must be grounded, preferred by the metallic process connection, alternatively by the cable shield. Install cable separated from power leading cables, if existing connect shield to earth. ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 14: Operation

    Min. valid measuring value conductivity Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 15 4 / Float - r Measuring value conductivity - not compensated 1113 Measure Value FV 4 / Float - r Measuring value pressure/fill level percentage ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 16: Error Diagnosis And Troubleshooting

    Disposal As required by the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE), products of ACS are marked with the depicted symbol in order to minimize the disposal of WEEE as unsorted municipal waste. Such products may not be disposed of as unsorted municipal waste and can be returned to ACS for disposal.
  • Page 17: Technical Data

    Measuring range – FSI ≤ 1... ≥ 10.000µS/cm Resolution ≤ 1µS/cm Characteristic deviation ≤ ±0,5% of measuring value (≥ ±1µS/cm) Temp. compensation -2%/K / -5…+45°C (+23°F… +113F) ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 18: Ausgänge

    0,375kg + (L1 x 0,068kg/m) >> [10-4] Temperature/Conductivity Y O U R P A R T N E R F O R M E A S U R E M E N T & A U T O M A T I O N www.acs-controlsystem.com...
  • Page 19: Materials

    BA03.22 • Electronic - output >> [09-A] 4…20mA FSK Chapter operation: BA09.22 • Addition UnitCode table Addition BA08.24 • Electronic - Function >> [10-4] Temperature/Conductivity ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany info@acs-controlsystem.de | +49 (0) 8721/9668-0...
  • Page 20 FEEL FREE TO CONTACT US ACS-CONTROL-SYSTEM GmbH Lauterbachstr. 57 84307 Eggenfelden - Germany info@acs-controlsystem.de www.acs-controlsystem.com +49 (0) 8721-9668-0 Y O U R PA R T N E R F O R M E A S U R E M E N T & A U T O M AT I O N...