6.6 ghz rf vector signal analyzer with digital downconversion (25 pages)
Summary of Contents for National Instruments NI PXIe-5622
Page 1
NI PXIe-5622 150 MS/s 16-Bit Oscilloscope/Digitizer for Communications In Stock Used and in Excellent Condition Open Web Page https://www.artisantg.com/89945-2 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
Page 2
Characteristics (or supplemental information) describe basic functions and attributes of the device established by design. Data in this document are Specifications unless otherwise noted. To access NI 5622 documentation, including the NI PXIe-5622 Getting Started Guide, go to Start»All Programs»National Instruments»NI-SCOPE»NI-SCOPE Documentation. Hot Surface If the NI 5622 has been in use, it may exceed safe handling temperatures and cause burns.
–0.7 Frequency (MHz) Dither is disabled by default in NI-SCOPE. To enable dithering, refer to the NI High-Speed Digitizers Help. 4 | ni.com | NI PXIe-5622 Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 7
Equalization requires using the Digital Filter Design Toolkit to compute equalization filter coefficients. This software is not included with the NI-SCOPE driver. 6 | ni.com | NI PXIe-5622 Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
25 MHz TClk Specifications You can use the National Instruments TClk synchronization method and the NI-TClk driver to align the Sample Clocks on any number of supported devices, in one or more chassis. For more information about TClk synchronization, refer to the NI-TClk Synchronization Help, which is located within the NI High-Speed Digitizers Help.
Record length refers to the number of samples, or data points, the NI-SCOPE device acquires for each channel in a single acquisition. 14 | ni.com | NI PXIe-5622 Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Using a decimation rate of 1 (sample rate of 150 MS/s with internal clock) bypasses the filters in the OSP block. Gain <1 attenuates user data (-0.5 × Vertical Range) ≤ Output ≤ (+0.5 × Vertical Range) 16 | ni.com | NI PXIe-5622 Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Interactive control of the NI 5622 was first available in NI-SCOPE SFP version 3.5. The NI-SCOPE SFP is included on the NI-SCOPE DVD. National Instruments Measurement & Automation Explorer (MAX) also provides interactive configuration and test tools for the NI 5622. MAX is included on the NI-SCOPE DVD.
National Instruments 符合中国电子信息产品中限制使用某些有害物 中国客户 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 。(For information about China RoHS ni.com/environment/rohs_china compliance, go to ni.com/environment/rohs_china 22 | ni.com | NI PXIe-5622 Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...