  • Page 1 QRD2 MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE INSTALLATION, USE AND MAINTENANCE MANUAL...
  • Page 2: Table Of Contents

    Istruzioni Originali QRD2 Unità di ventilazione con recupero di calore Leggere questo manuale attentamente prima di utilizzare il prodotto e conservarlo in un posto sicuro così da poterlo consultare all’occorrenza. Il prodotto è costruito a regola d’arte e nel rispetto delle normative vigenti in materia di apparecchiature elettriche e deve essere installato da personale tecnicamente qualificato.
  • Page 3: Avvertenze E Precauzioni

    3 INFORMAZIONI DI PRODOTTO 3.1 Generale Questo documento è il Manuale di Installazione, Uso e Manutenzione delle unità di ventilazione con recupero di calore QRD2. Esso include informazioni di base e raccomandazioni relative all’installazione, alla messa in servizio e alle operazioni di manutenzione per assicurarne il funzionamento corretto.
  • Page 4: Dimensioni E Peso

    This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or Materiale/Material: Data/Date: Firma/Signature: aera Tel +39 030 674681 Fax +39 030 687214 disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Materiale/Material: Data/Date: Firma/Signature: C.F. e P.IVA 03369930981 - REA BS-528 Dimensioni in mm.
  • Page 5: Trasporto E Stoccaggio

    Aerauliqa srl This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Aerauliqa SRL a socio unico Sede legale/registered office: via M.
  • Page 6 This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved. disclosed without the specific written consent of Aerauliqa srl. All right are reserved.
  • Page 7: Collegamento Elettrico Precablato

    5.4 Collegamento elettrico precablato ATTENZIONE Assicurarsi che l’interruttore generale dell’impianto sia spento prima di qualsiasi operazione di installazione, manutenzione ordinaria o straordinaria o collegamento elettrico! ATTENZIONE L’installazione e la manutenzione dell’unità e del sistema di ventilazione completo deve essere eseguito da un installatore autorizzato e in conformità...
  • Page 8: Collegamenti Elettrici Aggiuntivi

    5.5 Collegamenti elettrici aggiuntivi ATTENZIONE Assicurarsi che l’interruttore generale dell’impianto sia spento prima di qualsiasi operazione di installazione, manutenzione ordinaria o straordinaria o collegamento elettrico! ATTENZIONE L’installazione e la manutenzione dell’unità e del sistema di ventilazione completo deve essere eseguito da un installatore autorizzato e in conformità...
  • Page 9: Messa In Servizio

    6 MESSA IN SERVIZIO 6.1 Settaggio velocità dei ventilatori La velocità dei ventilatori può essere regolata durante l‘installazione in base al tasso di ventilazione richiesta (§7). 6.2 Prima di avviare il sistema Ad installazione ultimata, prima di avviare l’unità verificate che: •...
  • Page 10: Funzionamento

    Aerauliqa srl This document is protected by privacy and copyright laws. No part of this document may be reproduced, ad disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Fig. 7.b CTRL-DSP DATA: indica la data corrente indica ALLARME ERRORE (vedere §7.3 per identificare il guasto)
  • Page 11: Menu Utente Sul Ctrl-Dsp

    Dopo la prima accensione dell’unità, il CTRL-DSP mostra la seguente schermata: Fig. 7.c Schermata avvio del CTRL-DSP. È possibile variare la velocità manualmente tra velocità 1-2-3 usando  oppure . 7.1 Menu utente sul CTRL-DSP Per entrare nel Menu utente premere OK o ESC. Per uscire dal Menu utente premere ESC o attendere circa 60 secondi.
  • Page 12 Permette di selezionare la velocità massima (Boost). Menu utente Premere OK per selezionarla. 1 Selezione Modalità Scegliere tra “Assente” o “Presente” usando  oppure . 2 Boost Premere OK per selezionare e tornare al menu precedente. 3 Durata Boost Impostazione di fabbrica (DEFAULT): Assente. 4 Reset Allarme FILTRO 5 Night Mode La velocità...
  • Page 13: Menu Installatore Sul Ctrl-Dsp

    Permette di impostare le fasce orarie e le velocità di funzionamento per tutto l’arco della Menu utente settimana quando l’unità è settata in Modalità Normale 3V. 1 Selezione Modalità Premere OK per selezionare. 2 Boost Scegliere tra “Assente” o “Presente” usando  oppure . 3 Durata Boost Premere OK per selezionare.
  • Page 14 Permette di selezionare la lingua tra English, Italiano, Deutsch, Čeština, Slovenský, Français, Menu installatore Español, Polish, 中国, Magyar e Русский. 1 Selezione lingua Premere OK per entrare. 2 Data/ora Scegliere la lingua usando  oppure . 4 Modalità Normale Premere OK per selezionare. 6 Impostazioni Bypass Alla prima accensione la lingua proposta è...
  • Page 15 Da selezionare nel caso in cui sia presente un elemento riscaldante esterno (non fornito). Menu installatore Premere OK per entrare. 8 Riscaldamento 10 Impostazione Velocità “1 Batteria riscaldante”. 11 Bilanciamento Portate Premere OK per entrare. 12 Filtro F7 Scegliere tra “Assente/PRE/POST” usando  oppure . 13 Intervallo Allarme Filtro Premere OK per selezionare.
  • Page 16 Permette di bilanciare i due flussi d’aria. Menu installatore Premere OK per entrare. 8 Riscaldamento Selezionare le voci dei sottomenu usando  oppure : premere OK per confermare. 10 Impostazione Velocità 11 Bilanciamento Portate 1 Bilanciamento Avanzato 12 Filtro F7 Permette di impostare il bilanciamento alle velocità...
  • Page 17 Permette di attivare un breve ciclo di funzionamento dei ventilatori a velocità 100% per due Menu installatore volte durante l’arco della giornata. 15 Pressione Costante Premere OK per entrare. 17 Scarico periodico Scegliere tra “Assente” o “Presente” usando  oppure . 18 Ore di funzionamento unità...
  • Page 18: Funzionalità Aggiuntive

    Permette di impostare il contrasto LCD. Menu installatore Premere OK per entrare. 21 Carica impostazioni Aumentare/diminuire il contrasto usando  oppure . 22 Reset Impostazioni di Fabbrica Premere OK per confermare. 23 Contrasto 24 Backlight 25 Debug page Permette di impostare il contrasto LCD. Menu installatore Premere OK per entrare.
  • Page 19: Manutenzione Ordinaria E Straordinaria

    8 MANUTENZIONE ORDINARIA E STRAORDINARIA ATTENZIONE Assicurarsi che le avvertenze e le precauzioni indicate nel Capitolo 2 sia attentamente lette, comprese e rispettate! La manutenzione ordinaria può essere eseguita dall’utente. La manutenzione straordinaria deve essere eseguita unicamente da un installatore autorizzato e in conformità alle norme e regolamenti locali in vigore.
  • Page 20: Manutenzione Ordinaria

    Scarico condensa A seconda del tasso di umidità relativo presente nell’aria estratta, può formarsi condensa sulle superfici fredde del pacco scambiatore, su un lato in inverno e sull’altro lato in estate. L’acqua di condensa è espulsa attraverso i raccordi di scarico condensa.
  • Page 21: Manutenzione Straordinaria

    8.4 Manutenzione straordinaria ATTENZIONE Assicurarsi che l’interruttore generale dell’impianto sia spento prima di qualsiasi operazione di installazione, manutenzione ordinaria o straordinaria o collegamento elettrico! ATTENZIONE L’installazione e la manutenzione dell’unità e del sistema di ventilazione completo deve essere eseguito da un installatore autorizzato e in conformità...
  • Page 22 • Pulire lo scambiatore ogni anno con un aspirapolvere. La necessità di eseguire questa operazione può variare da caso in caso a seconda delle condizioni ambientali interne ed esterne e della frequenza con la quale vengono puliti i filtri. Per estrarre il pacco scambiatore sbloccare l’apposita staffa di fissaggio tramite la vite apposita (Fig.
  • Page 23: Risoluzione Guasti

    8.5 Risoluzione guasti I ventilatori non si attivano 1. Verificare che l’unità sia sotto tensione. 2. Verificare che tutti i collegamenti funzionino correttamente (collegamenti nella scatola collegamenti elettrici e al gruppo dei ventilatori in immissione ed estrazione). Volume d’aria ridotto 1.
  • Page 24: Fiche Tecnica Erp

    Translated from Original Instructions QRD2 Heat Recovery Ventilation Unit Read this manual carefully before using the product and keep it in a safe place for reference as necessary. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 25: Product Information

    The key to proper, safe and smooth operation of the unit is to read this manual thoroughly, use the unit according to given guidelines and follow all safety requirements. The unit QRD2 is supplied with the CTRL-DSP remote multifunction control panel as standard and with 2 condensation elbows and 2 plugs for the water drainage.
  • Page 26: Rating Label

    This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or aera Materiale/Material: Data/Date: Firma/Signature: Tel +39 030 674681 Fax +39 030 687214 disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Materiale/Material: Data/Date: Firma/Signature: C.F. e P.IVA 03369930981 - REA BS-528 Dimensions in mm Questo documento è...
  • Page 27: Transport And Storage

    Aerauliqa srl This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Aerauliqa SRL a socio unico Sede legale/registered office: via M.
  • Page 28 This document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved. disclosed without the specific written consent of Aerauliqa srl. All right are reserved.
  • Page 29 5.4 Precabled electric connections WARNING Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work! WARNING The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules and regulations.
  • Page 30 5.5 Additional electric connections WARNING Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work! WARNING The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules and regulations.
  • Page 31 6 COMMISSIONING 6.1 Setting Fan speed The speed of the unit can be adjusted during installation according to required ventilation rate (§7). 6.2 Before starting the system When the installation is finished, check that: • Filters are mounted correctly. • The unit is installed in accordance with the instructions. •...
  • Page 32: Operation

    Aerauliqa srl This document is protected by privacy and copyright laws. No part of this document may be reproduced, ad disclosed without the specific written consent of Aerauliqa srl. All right are reserved. Fig. 7.b CTRL-DSP DATE: shows the current date shows ERROR ALARM (see §7.3 to check the type of error)
  • Page 33: User Menu On Ctrl-Dsp

    When powered on, the CTRL-DSP displays as follows: Fig. 7.c CTRL-DSP operation screen The speed (1-2-3) can be manually changed using  or . 7.1 User Menu on CTRL-DSP To enter the User Menu press OK or ESC. To exit the User Menu press ESC or wait for about 60 seconds. Select the menu item using ...
  • Page 34 It allows to select the maximum speed (BOOST). User Menu Press OK to select. 1 Mode Selection Choose NO or YES using  or . 2 Boost Press OK to select and go back to the previous menu. 3 Boost Duration Factory setting (DEFAULT): NO.
  • Page 35: Installer Menu

    It allows to set the time slots and the operating speeds throughout the week when the unit is User Menu set to Normal Mode 3V. 1 Mode Selection Press OK to select. 2 Boost Choose NO or YES using  or . 3 Boost Duration Press OK to select.
  • Page 36 It allows to select one language among English, Italiano, Deutsch, Čeština, Slovenský, Français, Installer Menu Español, Polish, 中国, Magyar e Русский. 1 Language Press OK to enter. 2 Date/time Select the language using  or . 4 Normal Mode Press OK to select. 6 Bypass settings Factory setting (DEFAULT) is: English.
  • Page 37 To be selected only in case an external heating element (not supplied with the unit) is used. Installer Menu Press OK to enter. 8 Heating 10 Speed setting “1 Heater” 11 Airflow Balancing Press OK to enter. 12 F7 filter Choose NO/PRE/POST using ...
  • Page 38 It allows to adjust the balancing of the two airflows. Installer Menu Press OK to enter. 8 Heating Select the submenu item using  or : press OK to confirm. 10 Speed setting 11 Airflow Balancing 1 Advanced Balancing 12 F7 filter It allows to set the airflow balancing at speed 1-2-3-Boost, in supply and extract, only if the 13 Filter Alarm interval unit operates in Normal Mode 3V.
  • Page 39 It allows to activate a short operation cycle of the fans at 100% speed for twice in a day. Installer Menu Press OK to enter. 15 Constant Pressure Choose NO or YES using  or . 17 Periodic purge Factory setting (DEFAULT): NO. 18 Working Hours Counter 19 ModBus settings If “YES”...
  • Page 40 It allows to set the LCD contrast. Installer Menu Press OK to enter. 21 Load Settings Increase/decrease the contrast using  or . 22 Restore Default Settings Press OK to confirm. 23 Contrast 24 Backlight 25 Debug page It allows to set the LCD contrast. Installer Menu Press OK to enter.
  • Page 41: Maintenance And Service

    8 MAINTENANCE AND SERVICE WARNING Make sure that specific warnings and cautions in Chapter 2 “Precautions” are carefully read, understood and applied! Maintenance can be carried out by the user. Service must be performed only by an authorized installer and in accordance with local rules and regulations. Questions regarding installation, use, maintenance and service of the unit should be answered by your installer or place of purchase! 8.1 Components list...
  • Page 42: Maintenance

    Condensation drainage Depending on the relative humidity in the extract air, condensation may occur on the cold surfaces of the heat exchanger, on one side in winter time, on the other side in summer time. The condensate water is led out through drainage pipes. Thermistors Temperature probes to implement temperature dependent functions.
  • Page 43 8.4 Service WARNING Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work! WARNING The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules and regulations.
  • Page 44 • Clean the heat exchanger every year with a vacuum cleaner. This may differ per situation depending on internal and external environmental conditions and on frequency of filter cleaning. To remove the heat exchanger unlock the specific bracket by turning the yellow screw (Fig. 8.h-j-k-n-o-p-q-r). SOSTITUISCE FIGURA 8_o SOSTITUISCE FIGURA 8_e SOSTITUISCE FIGURA 8_n...
  • Page 45: Disposal And Recycling

    8.5 Troubleshooting Fans do not start 1. Check that main supply gets to the unit. 2. Check that all connections are working (all connections in terminal box and fast couplings of intake and exhaust air fans). Reduced airflow 1. Check setting of fan speed on the CTRL-DSP (controller supplied). 2.
  • Page 46 10. Direttiva ErP - Regolamenti 1253/2014 - 1254/2014 ErP Directive - Regulations 1253/2014 - 1254/2014 Marchio AERAULIQA Mark Modello QRD2 Model Non residenziale; Tipologia unità bidirezionale Unit typology Non-residential; bidirectional Azionamento a velocità Tipo azionamento variabile; Type of drive Variable speed drive...
  • Page 47 NOTE...
  • Page 48 Tel: +39 030 674681 - Fax: +39 030 6872149 - www.aerauliqa.com - info@aerauliqa.it Aerauliqa srl si riserva il diritto di modificare/apportare migliorie ai prodotti e/o alle istruzioni di questo manuale in qualsiasi momento e senza preavviso. Aerauliqa srl reserves the right to modify/make improvements to products and/or this instruction manual at any time and without prior notice.