  • Page 1 DE3306 User manual...
  • Page 2 Contents 6 Cleaning   1 Important   Cleaningthebodyofthe Safety   dehumidifier   WARNINGforUsingR290 Cleaningthewatertank   Refrigerant   Cleaningthebackcover   2 Your Air Dehumidifier   7 Storage   ProductOverview   ControlsOverview   8 Troubleshooting   3 Getting started   9 Warranty and support   Beforefirstuse   Orderpartsoraccessories   Positioningthedehumidifier   Usingthearomafunction   10 Notices   Electromagneticfields(EMF)   4 Using the dehumidifier   Recycling   Thehumiditylight   Onorstandby   Settingthehumiditylevel   Continuousmode   SelectingtheAutomode   Changingthefanspeed   Selectinglaundrydryingmode   14 Usingtheswingfunction   SettingtheTimer  ...
  • Page 3 Don't add essential oils to other parts, • If the power cord is damaged, you must otherwise the parts will be damaged by the have it replaced by Philips, a service center oil. authorized by Philips, or similarly qualified •...
  • Page 4 • Do not use the dehumidifier for food • Do not use the dehumidifier in a bathroom preservation, art or scientific works. or other places where it is likely to come in • Do not point the airflow of the contact with water, or wash it with water.
  • Page 5 WARNING for Using R290 Refrigerant Referoperatorsmanual. Readtechnicalmanual. Warning: flammable material IMPORTANT NOTE: Readthismanualcarefullybeforeinstallingoroperatingyour unit.Makesuretosavethismanualforfuturereference. Theapplianceshallbeinstalled,operatedandstoredinaroomwithafloorarealargerthan4m Compliancewithnationalgasregulationsshallbeobserved. Theapplianceshallbestoredinawell-ventilatedareawheretheroomsizecorrespondstotheroom areaasspecifiedforoperation. Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample: openflames,anoperatinggasapplianceoranoperatingelectricheater). Anypersonwhoisinvolvedwithworkingonorbreakingintoarefrigerantcircuitshouldholdacurrent validcertificatefromanindustry-accreditedassessmentauthority,whichauthorisestheircompetence tohandlerefrigerantssafelyinaccordancewithanindustryrecognisedassessmentspecification. Servicingshallonlybeperformedasrecommendedbytheequipmentmanufacturer. Maintenanceandrepairrequiringtheassistanceofotherskilledpersonnelshallbecarriedoutunder thesupervisionofthepersoncompetentintheuseofflammablerefrigerants. Information for the use of Flammable refrigerants WARNING • Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthoserecommended bythemanufacturer. • Donotpierceorburn. • Beawarethatrefrigerantsmightnotcontainanodour.
  • Page 6 • Servicingshallonlybeperformed HaveadrypowderorCO fireextinguisher asrecommendedbytheequipment adjacenttothechargingarea. manufacturer.Maintenanceandrepair No ignition sources requiringtheassistanceofotherskilled • Nopersoncarryingoutworkinrelation personnelshallbecarriedoutunderthe toarefrigeratingsystemwhichinvolves supervisionofapersoncompetentinusing exposinganypipeworkshalluseany flammablerefrigerants. sourcesofignitioninsuchamanner Information on servicing thatitcanleadtotheriskoffireor explosion.Allpossibleignitionsources, Servicepersonnelshallundertakethefollowing includingcigarettesmoking,should whenservicinganappliancethatemploysa bekeptsufficientlyfarawayfromthe flammablerefrigerant. siteofinstallation,repairing,removal Checks to the area anddisposal,duringwhichflammable • Priortobeginningworkonsystems refrigerantcanpossiblybereleasedtothe containingflammablerefrigerants,safety surroundingspace.Priortoworktaking checksarenecessarytoensurethatthe place,theareaaroundtheequipmentis riskofignitionisminimised.Forrepairto...
  • Page 7 Cabling andsignsthatareillegibleshallbe corrected; • Checkthatcablingwillnotbesubject • refrigerationpipeorcomponents towear,corrosion,excessivepressure, areinstalledinapositionwhere vibration,sharpedgesoranyother theyareunlikelytobeexposedto adverseenvironmentaleffects.Thecheck anysubstancewhichmaycorrode shallalsotakeintoaccounttheeffectsof refrigerantcontainingcomponents, agingorcontinualvibrationfromsources unlessthecomponentsare suchascompressorsorfans. constructedofmaterialswhichare Detection of flammable inherentlyresistanttobeingcorroded refrigerants oraresuitablyprotectedagainstbeing socorroded. • Undernocircumstancesshallpotential sourcesofignitionbeusedinthe Checks to electrical devices searchingforordetectionofrefrigerant • Repairandmaintenancetoelectrical leaks.Ahalidetorch(oranyotherdetector componentsshallincludeinitialsafety usinganakedflame)shallnotbeused. checksandcomponentinspection • Thefollowingleakdetectionmethodsare procedures.Ifafaultexiststhatcould deemedacceptableforsystemscontaining compromisesafety,thennoelectrical...
  • Page 8 • practiceisfollowedsinceflammabilityis mechanicalhandlingequipmentis aconsideration.Thefollowingprocedure available,ifrequired,forhandling shallbeadheredto: refrigerantcylinders; • • removerefrigerant; allpersonalprotectiveequipmentis • purgethecircuitwithinertgas; availableandbeingusedcorrectly; • • evacuate; therecoveryprocessissupervisedatall • purgeagainwithinertgas; timesbyacompetentperson; • • openthecircuitbycuttingorbrazing. recoveryequipmentandcylindersconform • Therefrigerantchargeshallberecovered totheappropriatestandards. intothecorrectrecoverycylinders.The d)Pumpdownrefrigerantsystem,ifpossible. systemshallbe“flushed”withOFNto e)Ifavacuumisnotpossible,makeamanifold rendertheunitsafe.Thisprocessmayneed sothatrefrigerantcanberemovedfromvarious toberepeatedseveraltimes.Compressed partsofthesystem. airoroxygenshallnotbeusedforthis f)Makesurethatthecylinderissituatedonthe task. scalesbeforerecoverytakesplace. •...
  • Page 9 refrigerant).Cylindersshallbecomplete Thestorageofequipmentshouldbe withpressurereliefvalveandassociated inaccordancewiththemanufacturer’s shut-offvalvesingoodworkingorder. instructions. Emptyrecoverycylindersareevacuated Storage of packed (unsold) and,ifpossible,cooledbeforerecovery equipment: occurs. • Therecoveryequipmentshallbeingood Storagepackageprotectionshouldbe workingorderwithasetofinstructions constructedsuchthatmechanicaldamage concerningtheequipmentthatisat totheequipmentinsidethepackagewillnot handandshallbesuitableforthe causealeakoftherefrigerantcharge. recoveryofflammablerefrigerant.In Themaximumnumberofpiecesofequipment addition,asetofcalibratedweighing permittedtobestoredtogetherwillbe scalesshallbeavailableandingood determinedbylocalregulations. workingorder.Hosesshallbecomplete withleak-freedisconnectcouplings andingoodcondition.Beforeusing therecoverymachine,checkthatitis insatisfactoryworkingorder,hasbeen properlymaintainedandthatany associatedelectricalcomponentsare sealedtopreventignitionintheevent ofarefrigerantrelease.Consultthe manufacturerifindoubt. • Therecoveredrefrigerantshallbereturned totherefrigerantsupplierinthecorrect recoverycylinder,andtherelevantWaste...
  • Page 10 Your Air Dehumidifier Congratulationsonyourpurchase,andwelcometoPhilips! TofullybenefitfromthesupportthatPhilipsoffers,registeryourproductatwww.philips.com/welcome. Product Overview Displaypanel Watertank Louver Continuousdrainageoutlet Airoutlet Powercordwrappinghandle Aromabox Backcover Humidityindicationlight Hose Omniwheels Aromapads...
  • Page 11 Controls Overview On/standbybutton Humiditysettingbutton Automodebutton Lighton/offbutton Laundrydryingmodebutton Autoswingbutton Fanspeedbutton Timerbutton Displayscreen Displaypanel Autodefrostingindicator Laundrydryingmodeicon Watertankfullalert Continuousmodeicon Automodeicon Timerindicator...
  • Page 12 Getting started Using the aroma function Before first use Note Beforeusingtheappliance,removeall packagingmaterials. • Only the aroma box is provided, the essential oils are not included with the product. Please purchase and use the Note essential oils if needed. • Make sure the product is disconnected •...
  • Page 13 Removethearomaboxfromthetopofthe Dropin2-3dropsofessentialoilstothe appliance. aromapad. Max 3 Removethecoverofthearomabox. Closethecoverofthearomaboxandput itbackontothetopofthedehumidifier. Removethepackingmaterialsofthe aromapadsandputonepieceofpadsinto aromabox. Using the dehumidifier The humidity light Humidity Ambient humidity level light color Blue ≤5(Lowerambienthumidity levelcomparedwithpreset humiditylevel) Purple 6-15(Mediumambient humiditylevelcomparedwith presethumiditylevel) >15(Higherambienthumidity levelcomparedwithpreset humiditylevel)
  • Page 14 Thehumiditylightautomaticallygoesonwhen theapplianceisswitchedon,andlightsupall colorsinsequence.Inashorttimethehumidity sensorsselectthecolorthatcorrespondstothe surroundinghumidity. On or standby Note • For optimum performance, close doors and windows. Note • Keep curtains away from the air inlet or air outlet. • When the humidity is decreased to • For optimum dehumidification efficiency, the selected level, the dehumidifier place the dehumidifier in a flat, stable automatically stops dehumidifying the air,...
  • Page 15 Selecting the Auto mode • TouchtheAutomodebutton toselect theAutomode. displays on the screen. » » The current humidity level displays on the screen. It automatically adjusts the fan speed based on the ambient humidity level. Note • Do not point the airflow of the dehumidifier directly at the body for a prolonged period of time.
  • Page 16 Whendefrostingisrequired: Touchthe buttonagaintodeactivate theswingfunction. » The indicator is on. » Defrosting will begin defrosting and continue until the dehumidifier is completely defrosted. • After the appliance is turned on, turn the louver upward to increase the dehumidifying efficiency. Setting the Timer Withthetimerfunction,youcanletthe dehumidifieroperateforasetnumberof hours.Whenthesettimehaselapsed,the...
  • Page 17 Draining the dehumidifier Emptying the water tank Whenthewatertankisfull: » The appliance beeps, and the indicator is on. Putthewatertankbackintothe dehumidifier. Holdtherecessofthewatertank,andpull itfromthedehumidifier. Note • The dehumidifier will resume working after the water tank is emptied. Using the continuous drainage Thedehumidifiercanalsodrainexcesswaterby attachingahose.Thisallowsyoutooperatethe Openthewatertankcoverandemptythe dehumidifierwithoutemptyingthewatertank.
  • Page 18 Cleaning the water tank Note • Put the water tank back in to the Cleanthewatertankeverydaytokeepitclean. dehumidifier even using the continuous Switchoffthedehumidifierandunplug drainage, or the dehumidifier can not fromtheelectricaloutlet. operate normally. • Make sure the hose fits tightly so that no Removethewatertankfromthe water leaks from the dehumidifier.
  • Page 19 Wipetheoutsideofthewatertankdry Pullthebackcover,andremoveitfromthe withacleancloth. dehumidifier. Ifthebackcoverisverydirty,useasoft Putthewatertankbackintothe brushtobrushawaythedust.Washthe dehumidifier. backcoverunderarunningtapwater. Allowthebackcovertoairdrythoroughly Cleaning the back cover beforeplacingbackinthedehumidifier. Putthebackcoverbackintotheappliance. Cleanthebackcoverwhennecessarytokeep itclean. Note • The back cover is washable and vacuum cleanable. Switchoffthedehumidifierandunplug fromtheelectricaloutlet. Puttheplugofthedehumidifierinthe walloutlet. Washyourhandsthoroughlyafter cleaningthebackcover.
  • Page 20 Storage Turnoffthedehumidifierandunplugfromthewalloutlet. Cleanthedehumidifier,emptythewatertankandwashthebackcover(seechapter‘Cleaning’). Letallpartsdrythoroughlybeforestoring. Storethedehumidifieruprightinacool,dryandwell-ventilatedlocation. Troubleshooting Thischaptersummarizesthemostcommonproblemsyoucouldencounterwiththedehumidifier.If youareunabletosolvetheproblemwiththeinformationbelow,visitwww.philips.com/supportor contacttheConsumerCareCenterinyourcountryforassistance. Problem Possible solution • Thetimerissettoaspecifictimeinterval.Resetorturnoffthetimer. Theappliancedoesnot • Tryadifferentelectricalsocketorcheckthewallswitch. workeventhoughitis pluggedintothewall • Makesurethatthewatertankisemptyandplacedinthe socketandswitchedon. dehumidifierproperly. Thewatertankisempty • Removethewatertankfromthedehumidifierandplaceitbackto butthe indictoris thedehumidifieragain. stillon. • Makesuretheairinletandoutletarenotblocked. Thereisnoair • Theroomhumidityisbelowwhatthedehumidifierissetto.Selecta dehumidification lowerhumiditylevel. intheroomorthe • Makesurethatnoexteriordoorsorwindowsareopen.
  • Page 21 Warranty and 10 Notices support Electromagnetic fields (EMF) Versunioffersatwo-yearwarrantyafter Thisappliancecomplieswiththeapplicable purchaseonthisproduct.Thiswarrantyisnot standardsandregulationsregardingexposure validifadefectisduetoincorrectuseorpoor toelectromagneticfields. maintenance.Ourwarrantydoesnotaffect yourrightsunderlawasaconsumer.Formore Recycling informationorforinvokingthewarranty, pleasevisitourwebsite Thissymbolmeansthatthisproduct www.philips.com/support. shallnotbedisposedofwithnormal householdwaste(2012/19/EU). Followyourcountry’srulesfortheseparate Order parts or accessories collectionofelectricalandelectronicproducts. Correctdisposalhelpspreventnegative Ifyouhavetoreplaceapartorwantto consequencesfortheenvironmentandhuman purchaseanadditionalpart,gotoyourPhilips health. dealerorvisitwww.philips.com/support. Ifyouhaveproblemsobtainingtheparts, pleasecontactthePhilipsConsumerCare Centerinyourcountry(youcanfinditsphone numberintheworldwideguaranteeleaflet).