ID number: This is the ID to recognize manufacturer of the exclusive Address upper byte message (manufacturer ID). The manufacturer ID of Roland is Address middle byte 41H. The ID numbers of 7EH and 7FH are expansion of MIDI...
MIDI Implementation 2. Parameter Address Map Start Address Description Start Address Description 17H 00H 00H Audio Parameter (Memory 4) 00H 00H 00H Video Parameter Area 18H 00H 00H Video Parameter (Memory 5) 01H 00H 00H Audio Parameter Area 02H 00H 00H System Parameter Area 19H 00H 00H Audio Parameter (Memory 5)
Page 4
MIDI Implementation Address Parameter name SysEx value Meaning of value 00H 00H 22H AUX 1 LAYER DSK 1 00H–02H DISABLE, ENABLE, ALWAYS ON 00H 00H 23H AUX 1 LAYER DSK 2 00H–02H DISABLE, ENABLE, ALWAYS ON 00H 00H 24H INPUT 11 ASSIGN 00H–20H HDMI 1–8, SDI 1–8, STILL 1–16, N/A 00H 00H 25H...
Page 5
MIDI Implementation Address Parameter name SysEx value Meaning of value 00H xxH 13H GREEN 40H–00H–3FH -64–0–63 00H xxH 14H BLUE 40H–00H–3FH -64–0–63 00H xxH 15H COLOR SPACE 00H–04H AUTO, RGB (0-255), RGB (16-235), YPbPr (SD), YPbPr (HD) 00H xxH 16H TEST PATTERN 00H–05H OFF, 75% COLOR BAR, 100% COLOR BAR, RAMP, STEP, HATCH...
Page 6
MIDI Implementation À MIX/WIPE Address Parameter name SysEx value Meaning of value 00H 18H 00H TRANSITION TYPE 00H–01H MIX, WIPE 00H 18H 01H MIX TYPE 00H–02H MIX, FAM, NAM HORIZONTAL, VERTICAL, UPPER LEFT, UPPER RIGHT, LOWER LEFT, LOWER RIGHT, 00H 18H 02H WIPE TYPE 00H–07H H-CENTER, V-CENTER...
Page 7
MIDI Implementation À PinP & KEY * xxH: 1BH–1EH (PinP & KEY 1–4) Address Parameter name SysEx value Meaning of value 00H xxH 00H PGM SW 00H–01H OFF, ON 00H xxH 01H PVW SW 00H–01H OFF, ON 00H xxH 02H SOURCE 00H–33H HDMI 1–8, SDI 1–8, STILL 1–16, INPUT 1–20...
Page 8
MIDI Implementation À DSK * xxH: 1FH–20H (DSK 1, 2) Address Parameter name SysEx value Meaning of value 00H xxH 00H PGM SW 00H–01H OFF, ON 00H xxH 01H PVW SW 00H–01H OFF, ON 00H xxH 02H DSK MODE 00H–02H SELF KEY, ALPHA KEY, EXTERNAL KEY 00H xxH 03H KEY SOURCE...
Page 9
MIDI Implementation ÁAudio Parameter Area À AUDIO INPUT * xxH: 00H–14H (AUDIO IN 1–3/4, USB IN, Bluetooth IN, HDMI IN 1–8, SDI IN 1–8) Address Parameter name SysEx value Meaning of value 01H xxH 00H ANALOG GAIN (*1) 00H–40H 0–64dB 01H xxH 01H DIGITAL GAIN 7CH 5CH–00H 00H–03H 24H...
Page 10
MIDI Implementation À AUDIO OUTPUT ASSIGN Address Parameter name SysEx value Meaning of value 01H 20H 00H AUDIO OUT (XLR) 00H–03H MASTER OUTPUT, AUX 1–3 01H 20H 01H AUDIO OUT (RCA) 00H–03H MASTER OUTPUT, AUX 1–3 01H 20H 02H PHONES OUT 00H–03H MASTER OUTPUT, AUX 1–3 01H 20H 03H...
Page 11
MIDI Implementation À AUDIO AUX 1 OUTPUT Address Parameter name SysEx value Meaning of value 01H 22H 00H 7EH 00H 00H, AUX 1 LEVEL -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 22H 03H AUX 1 MUTE 00H–01H OFF, ON 01H 22H 04H AUX 1 DELAY...
Page 12
MIDI Implementation Address Parameter name SysEx value Meaning of value 01H 22H 37H 7EH 00H 00H, AUX 1 SEND AUDIO IN 1 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 22H 3AH 7EH 00H 00H, AUX 1 SEND AUDIO IN 2 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 1H 22H 3DH...
Page 13
MIDI Implementation À AUDIO USB OUTPUT Address Parameter name SysEx value Meaning of value 01H 23H 00H 7EH 00H 00H, USB OUT LEVEL -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 23H 03H USB OUT MUTE 00H–01H OFF, ON 01H 23H 04H AUX DELAY 00H 00H–27H 08H...
Page 14
MIDI Implementation À AUDIO AUX 2 OUTPUT Address Parameter name SysEx value Meaning of value 01H 25H 00H 7EH 00H 00H, AUX 2 LEVEL -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 25H 03H AUX 2 MUTE 00H–01H OFF, ON 01H 25H 04H AUX 2 DELAY...
Page 15
MIDI Implementation Address Parameter name SysEx value Meaning of value 01H 25H 37H 7EH 00H 00H, AUX 2 SEND AUDIO IN 1 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 25H 3AH 7EH 00H 00H, AUX 2 SEND AUDIO IN 2 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 1H 25H 3DH...
Page 16
MIDI Implementation À AUDIO AUX 3 OUTPUT Address Parameter name SysEx value Meaning of value 01H 26H 00H 7EH 00H 00H, AUX 3 LEVEL -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 26H 03H AUX 3 MUTE 00H–01H OFF, ON 01H 26H 04H AUX 3 DELAY...
Page 17
MIDI Implementation Address Parameter name SysEx value Meaning of value 01H 26H 37H 7EH 00H 00H, AUX 3 SEND AUDIO IN 1 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 01H 26H 3AH 7EH 00H 00H, AUX 3 SEND AUDIO IN 2 -INFdB, -80.0–0.0–10.0dB 7FH 79H 60H–00H 00H 00H–00H 00H 64H 1H 26H 3DH...
Page 18
MIDI Implementation À AUDIO FOLLOW Address Parameter name SysEx value Meaning of value 01H 30H 00H HDMI IN 1 00H–01H OFF, ON 01H 30H 01H HDMI IN 2 00H–01H OFF, ON 01H 30H 02H HDMI IN 3 00H–01H OFF, ON 01H 30H 03H HDMI IN 4 00H–01H...
Page 19
MIDI Implementation Address Parameter name SysEx value Meaning of value 01H 31H 21H SDI IN 4 SW 00H–01H DISABLE, ENABLE 01H 31H 22H SDI IN 4 WEIGHT 00H–64H 0–100% 01H 31H 23H SDI IN 5 SW 00H–01H DISABLE, ENABLE 01H 31H 24H SDI IN 5 WEIGHT 00H–64H 0–100%...
Page 20
MIDI Implementation ÁSystem Parameter Area À Version Address Parameter name SysEx value Meaning of value 02H 00H 00H System Version Major 00H–09H 0–9 02H 00H 01H System Version Minor (1) 00H–09H 0–9 02H 00H 02H System Version Minor (2) 00H–09H 0–9 02H 00H 03H System Version Build (1)
Page 21
MIDI Implementation Address Parameter name SysEx value Meaning of value 02H 01H 2EH TEST PATTERN 00H–05H OFF, 75% COLOR BAR, 100% COLOR BAR, RAMP, STEP, HATCH 02H 01H 2FH TEST PATTERN MOTION 00H–02H DISABLE, SLOW, FAST 02H 01H 30H TEST TONE LEVEL 00H–03H OFF, -20dB, -10dB, 0dB 02H 01H 31H...
Page 22
MIDI Implementation À PANEL LOCK Address Parameter name SysEx value Meaning of value 02H 02H 00H A/PGM 1 SW 00H–01H OFF, ON 02H 02H 01H A/PGM 2 SW 00H–01H OFF, ON 02H 02H 02H A/PGM 3 SW 00H–01H OFF, ON 02H 02H 03H A/PGM 4 SW 00H–01H...
Page 23
MIDI Implementation Address Parameter name SysEx value Meaning of value 02H 02H 3CH PinP & KEY 4 PVW SW 00H–01H OFF, ON 02H 02H 3DH DSK 1 PVW SW 00H–01H OFF, ON 02H 02H 3EH DSK 2 PVW SW 00H–01H OFF, ON 02H 02H 3FH PinP &...
Page 24
MIDI Implementation À FREEZE Address Parameter name SysEx value Meaning of value 02H 05H 00H FREEZE SW 00H–01H OFF, ON 02H 05H 01H FREEZE TYPE 00H–01H ALL, SELECT 02H 05H 02H FREEZE SELECT HDMI IN 1 00H–01H DISABLE, ENABLE 02H 05H 03H FREEZE SELECT HDMI IN 2 00H–01H DISABLE, ENABLE...
Page 25
MIDI Implementation À AUTO SWITCHING (PinP & KEY 1 SCAN) Address Parameter name Meaning of value SysEx value 02H 34H 00H PinP & KEY 1 SCAN SEQUENCE 00H–02H NORMAL, REVERSE, RANDOM 02H 34H 01H PinP & KEY 1 SCAN TIME / HDMI IN 1 00H–78H OFF, 1–120sec 02H 34H 02H...
Page 26
MIDI Implementation Address Parameter name Meaning of value SysEx value 02H 35H 1AH PinP & KEY 2 SCAN TIME / STILL 10 00H–78H OFF, 1–120sec 02H 35H 1BH PinP & KEY 2 SCAN TIME / STILL 11 00H–78H OFF, 1–120sec 02H 35H 1CH PinP &...
Page 27
MIDI Implementation Address Parameter name Meaning of value SysEx value 02H 37H 10H PinP & KEY 4 SCAN TIME / SDI IN 8 00H–78H OFF, 1–120sec 02H 37H 11H PinP & KEY 4 SCAN TIME / STILL 1 00H–78H OFF, 1–120sec 02H 37H 12H PinP &...
Page 28
MIDI Implementation À AUTO SWITCHING (DSK 2 SCAN) Address Parameter name Meaning of value SysEx value 02H 39H 00H DSK 2 SCAN SEQUENCE 00H–02H NORMAL, REVERSE, RANDOM 02H 39H 01H DSK 2 SCAN TIME / HDMI IN 1 00H–78H OFF, 1–120sec 02H 39H 02H DSK 2 SCAN TIME / HDMI IN 2 00H–78H...
Page 29
02H 09H 4AH TALLY SETTINGS AUX 2 00H–01H DSIABLE, ENABLE 02H 09H 4BH TALLY SETTINGS AUX 3 00H–01H DSIABLE, ENABLE À Roland FILL+KEY Address Parameter name SysEx value Meaning of value 02H 0CH 00H MODE 00H–02H OFF, DSK 1, DSK 2 À...
Page 30
MIDI Implementation À CAMERA CONTROL COMMON Address Parameter name Meaning of value SysEx value 02H 40H 00H CAMERA ID 00H–0FH CAMERA 1–16 02H 40H 01H CAMERA MODE 00H–01H OFF, ON 02H 40H 02H ALL CAMERAS RECALL 00H–01H OFF, ON À CAMERA CONTROL * xxH: 41H–50H (CAMERA 1–16) Address Parameter name...
Page 31
MIDI Implementation ÁOther Parameter Area À Memory Address Parameter name SysEx value Meaning of value 0AH 00H 00H Memory Load Trigger 00H–1DH Memory 1–30 (Write only) 0AH 00H 01H Memory Save Trigger 00H–1DH Memory 1–30 (Write only) 0AH 00H 02H Memory Initialize Trigger 00H–1DH Memory 1–30 (Write only)
Page 32
MIDI Implementation Address Parameter name SysEx value Meaning of value 0BH 00H 35H PinP & KEY 2 [PVW] button 00H–01H Release, press (Write Only) 0BH 00H 36H PinP & KEY 2 [PGM] button 00H–01H Release, press (Write Only) 0BH 00H 37H PinP &...
Page 33
MIDI Implementation Address Parameter name SysEx value Meaning of value 0CH 00H 1CH STILL 13 TALLY 00H–03H OFF, PGM, PST, PGM&PST (Read only) 0CH 00H 1DH STILL 14 TALLY 00H–03H OFF, PGM, PST, PGM&PST (Read only) 0CH 00H 1EH STILL 15 TALLY 00H–03H OFF, PGM, PST, PGM&PST (Read only) 0CH 00H 1FH...
Page 34
MIDI Implementation ÁMacro Area À Macro Command Address Parameter name SysEx value Meaning of value 50H 05H 00H (reserved) 50H 05H 01H (reserved) 50H 05H 02H (reserved) 50H 05H 03H (reserved) 50H 05H 04H EXEC MACRO TRIGGER 00H–63H MACRO 1–100 50H 05H 05H PREVIEW MACRO TRIGGER 00H–63H...
ÁExample of an Exclusive Message and Calculating a Checksum (Hexadecimal Numbers are Indicated by “H”) Roland Exclusive messages are transmitted with a checksum at the end (before F7) In MIDI documentation, data values and addresses/sizes of exclusive messages etc. to make sure that the message was correctly received. The value of the checksum is are expressed as hexadecimal values for each 7 bits.
LAN/RS-232 Command Reference The V-160HD support two types of remote-interface communication: LAN and RS-232. Using the LAN CONTROL port or RS-232 connector to send specific commands to the V-160HD from a controlling device lets you operate the V-160HD remotely. LAN Interface...
Version information stxVER; a: V-160HD (Product name) b: Version number <Example> 1.00 Flow control Flow control xoff Commands spontaneously sent from the V-160HD Sent Response Item Parameter command command stxERR:a; a: 0 (syntax error) The received command contains an error.
Need help?
Do you have a question about the V-160HD and is the answer not in the manual?
Questions and answers