Page 2
TYPICAL SECTION DRAWING FOR SSM33/SSM33I SERIES 20 Piggy-Back Control Control Vertical Float Switch 10’ Cord Control Vertical Float Switch 20’ Cord. Not Shown (Automatic Only) 21 Cable Tie. Not Shown (Automatic Only)
Page 3
TYPICAL SECTION DRAWING FOR SRM4 SERIES 20 Piggy-Back Control 21 Cable Tie Not Shown (Automatic Only)
Page 4
PARTS LIST SSM33/SSM33I AND SRM4 Part Part Description Req’d Numbers Description Req’d Numbers Ring, Lift 26230A000 Plate, Bottom, with Volute Case 27005D000 Plug, 1/4” NPT 05022A056 Screw, Tapping, #10 x 1” Lg. 09822A036 (SSM33, SRM4) Plate, Name (Not Stamped) 23780A000 Screw, Tapping, #10 x ¾”...
NOTE: READ THESE INSTRUCTIONS LEVEL CONTROLS CAREFULLY BEFORE ATTEMPTING TO The automatic models come with 10’ or 20’ power cord and mechanical (mercury free), piggy-back float switch. The 115 INSTALL PUMP. or 230 volt piggy-back switch is tethered directly to the pump. The switch can optionally be mounted to the discharge pipe DESCRIPTION AND APPLICATION using a minimum 3-5/8”...
UL AND CSA APPROVAL POINTS TO CHECK IF PUMP DOES NOT RUN OR DOES NOT RUN PROPERLY All pumps have UL and CSA approval pending. Myers is a SSPMA certified pump member. (1) Pump does not run or start when water is up in tank. (a) Check for blown fuse or tripped circuit breaker.
Page 7
TYPICAL SUMP INSTALLATION FOR SSM33/SSM33I Series...
Page 8
TYPICAL SUMP INSTALLATION FOR SRM4 SERIES...
Page 9
CAUTION: FOR ANY WORK ON PUMP (6) Carefully remove the new seal assembly from the package. Add a film of new oil to the rubber O.D. on the OR SWITCH, ALWAYS UNPLUG POWER stationary portion (carbon), and insert into the seal CORD.
(9) Place the pump motor assembly upright and set it Clean surface area and place new o-ring into position. into the volute case. Replace the four cap screws and Be careful not to cut o-ring when installing. tighten. (4) Position new motor housing (with new stator), onto the (10) Replace oil in the motor housing using only Myers pump assembly.
Page 11
SSM33I SERIES DIMENSIONAL DRAWINGS SRM4 DIMENSIONAL DRAWING...
Limited Warranty Myers ® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Jet pumps, small centrifugal pumps, submersible pumps and 12 months from date of original installation, related accessories...
Page 14
Dibujo de corte típico para la serie SSM33/SSM33I Control superpuesto Interruptor de control del flotador vertical Cordón de 10 pies de largo Interruptor de control del flotador vertical Cordón de 20 pies de largo. No se ilustra (Sólo en modelos automáticos) Amarre del cable.
Page 15
Dibujo de corte típico para la serie SRM4 Control superpuesto Amarre del cable. No se ilustra (Sólo en modelos automáticos)
Page 16
Lista de piezas para SSM33/SSM33I y SRM4 Piezas Piezas nece- nece- Ref. Descripción y No. sarias Números Ref. Descripción y No. sarias Números Placa, Inferior, con Cubierta en Aro, alza 26230A000 27005D000 voluta Tapón, 1/4” NPT 05022A056 Tornillo, Enrosque hembra , #10 x 1” 09822A036 Placa, de fábrica (no estampada) 23780A000...
NOTA: lea estas instrucciones con Controles de nivel atención antes de tratar de instalar Los modelos automáticos vienen con un cordón eléctrico de 10 o 20 pies de largo y un interruptor de flotador superpuesto la bomba mecánico (sin mercurio). El interruptor superpuesto de 115 o de 230 voltios viene anclado directamente a la bomba.
Aprobación de UL y de CSA Puntos a verificar si la bomba no marcha o no funciona correctamente Todas las bombas tienen la aprobación de UL y de CSA en trámite. Myers es un miembro de bombas certificado de (1) La bomba no funciona ni se enciende cuando el nivel del la SSPMA.
Page 19
Instalación típica en sumidero para la serie SSM33/SSM33I Receptáculo tipo puesta a tierra de 115 o 230 voltios. Altura mín. Sobre el suelo 4 pies. Cordón de la bomba se enchufa en la serie con cordón para operación automática. Cordón de la bomba se puede enchufar directamente en el receptáculo para operación manual.
Page 20
Instalación típica en sumidero para la serie SRM4 Receptáculo tipo puesta a tierra de 115 o 230 voltios. Altura mín. Sobre el suelo 4 pies. Cordón de la bomba se enchufa en la serie con cordón para operación automática. Cordón de la bomba se puede enchufar directamente en el receptáculo para operación manual.
Page 21
Precaución: para realizar cualquier trabajo en la (6) Saque cuidadosamente la nueva unidad de junta del paquete. Agregue una capa de aceite nuevo al diámetro exterior de bomba o en el interruptor, siempre desenchufe caucho en la porción fija (carbono) e introdúzcala en la cavidad el cordón eléctrico;...
impulsor gire libremente después de haberlo apretado. la superficie y coloque el nuevo aro tórico en posición. Tenga (9) Coloque la unidad del motor de la bomba en posición vertical y cuidado de no cortar el aro tórico cuando lo instale. acomódelo en la cubierta en voluta.
Page 23
Dibujos dimensionales de la serie SSM33I Encender Apagar Dibujos dimensionales de la serie SRM4 Encender Apagar...
GARANTÍA LIMITADA Myers le garantiza al consumidor inicial (“Comprador” o “Usted”) de los productos indicados a continuación, que éstos estarán libres de defectos en materiales y en mano de obra durante el Período de Garantía especificado a continuación. Producto Período de garantía lo que ocurra primero: Bombas de chorro, pequeñas bombas centrífugas, bombas 12 meses desde la fecha de la instalación inicial, o...
Page 26
TYPICAL SECTION DRAWING FOR SSM33/SSM33I SERIES 20 Piggy-Back Control Control Vertical Float Switch 10’ Cord Control Vertical Float Switch 20’ Cord. Not Shown (Automatic Only) 21 Cable Tie. Not Shown (Automatic Only)
Page 27
TYPICAL SECTION DRAWING FOR SRM4 SERIES 20 Piggy-Back Control 21 Cable Tie Not Shown (Automatic Only)
Page 28
PARTS LIST SSM33/SSM33I AND SRM4 Part Part Description Req’d Numbers Description Req’d Numbers Ring, Lift 26230A000 Plate, Bottom, with Volute Case 27005D000 Plug, 1/4” NPT 05022A056 Screw, Tapping, #10 x 1” Lg. 09822A036 (SSM33, SRM4) Plate, Name (Not Stamped) 23780A000 Screw, Tapping, #10 x ¾”...
Page 29
NOTE: READ THESE INSTRUCTIONS LEVEL CONTROLS CAREFULLY BEFORE ATTEMPTING TO The automatic models come with 10’ or 20’ power cord and mechanical (mercury free), piggy-back float switch. The 115 INSTALL PUMP. or 230 volt piggy-back switch is tethered directly to the pump. The switch can optionally be mounted to the discharge pipe DESCRIPTION AND APPLICATION using a minimum 3-5/8”...
Page 30
UL AND CSA APPROVAL POINTS TO CHECK IF PUMP DOES NOT RUN OR DOES NOT RUN PROPERLY All pumps have UL and CSA approval pending. Myers is a SSPMA certified pump member. (1) Pump does not run or start when water is up in tank. (a) Check for blown fuse or tripped circuit breaker.
Page 31
TYPICAL SUMP INSTALLATION FOR SSM33/SSM33I Series...
Page 32
TYPICAL SUMP INSTALLATION FOR SRM4 SERIES...
Page 33
CAUTION: FOR ANY WORK ON PUMP (6) Carefully remove the new seal assembly from the package. Add a film of new oil to the rubber O.D. on the OR SWITCH, ALWAYS UNPLUG POWER stationary portion (carbon), and insert into the seal CORD.
Page 34
(9) Place the pump motor assembly upright and set it Clean surface area and place new o-ring into position. into the volute case. Replace the four cap screws and Be careful not to cut o-ring when installing. tighten. (4) Position new motor housing (with new stator), onto the (10) Replace oil in the motor housing using only Myers pump assembly.
Page 35
SSM33I SERIES DIMENSIONAL DRAWINGS SRM4 DIMENSIONAL DRAWING...
Page 36
Limited Warranty Myers ® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period whichever occurs first: Jet pumps, small centrifugal pumps, submersible pumps and 12 months from date of original installation, related accessories...
Page 38
Dibujo de corte típico para la serie SSM33/SSM33I Control superpuesto Interruptor de control del flotador vertical Cordón de 10 pies de largo Interruptor de control del flotador vertical Cordón de 20 pies de largo. No se ilustra (Sólo en modelos automáticos) Amarre del cable.
Page 39
Dibujo de corte típico para la serie SRM4 Control superpuesto Amarre del cable. No se ilustra (Sólo en modelos automáticos)
Page 40
Lista de piezas para SSM33/SSM33I y SRM4 Piezas Piezas nece- nece- Ref. Descripción y No. sarias Números Ref. Descripción y No. sarias Números Placa, Inferior, con Cubierta en Aro, alza 26230A000 27005D000 voluta Tapón, 1/4” NPT 05022A056 Tornillo, Enrosque hembra , #10 x 1” 09822A036 Placa, de fábrica (no estampada) 23780A000...
Page 41
NOTA: lea estas instrucciones con Controles de nivel atención antes de tratar de instalar Los modelos automáticos vienen con un cordón eléctrico de 10 o 20 pies de largo y un interruptor de flotador superpuesto la bomba mecánico (sin mercurio). El interruptor superpuesto de 115 o de 230 voltios viene anclado directamente a la bomba.
Page 42
Aprobación de UL y de CSA Puntos a verificar si la bomba no marcha o no funciona correctamente Todas las bombas tienen la aprobación de UL y de CSA en trámite. Myers es un miembro de bombas certificado de (1) La bomba no funciona ni se enciende cuando el nivel del la SSPMA.
Page 43
Instalación típica en sumidero para la serie SSM33/SSM33I Receptáculo tipo puesta a tierra de 115 o 230 voltios. Altura mín. Sobre el suelo 4 pies. Cordón de la bomba se enchufa en la serie con cordón para operación automática. Cordón de la bomba se puede enchufar directamente en el receptáculo para operación manual.
Page 44
Instalación típica en sumidero para la serie SRM4 Receptáculo tipo puesta a tierra de 115 o 230 voltios. Altura mín. Sobre el suelo 4 pies. Cordón de la bomba se enchufa en la serie con cordón para operación automática. Cordón de la bomba se puede enchufar directamente en el receptáculo para operación manual.
Page 45
Precaución: para realizar cualquier trabajo en la (6) Saque cuidadosamente la nueva unidad de junta del paquete. Agregue una capa de aceite nuevo al diámetro exterior de bomba o en el interruptor, siempre desenchufe caucho en la porción fija (carbono) e introdúzcala en la cavidad el cordón eléctrico;...
Page 46
impulsor gire libremente después de haberlo apretado. la superficie y coloque el nuevo aro tórico en posición. Tenga (9) Coloque la unidad del motor de la bomba en posición vertical y cuidado de no cortar el aro tórico cuando lo instale. acomódelo en la cubierta en voluta.
Page 47
Dibujos dimensionales de la serie SSM33I Encender Apagar Dibujos dimensionales de la serie SRM4 Encender Apagar...
Page 48
GARANTÍA LIMITADA Myers le garantiza al consumidor inicial (“Comprador” o “Usted”) de los productos indicados a continuación, que éstos estarán libres de defectos en materiales y en mano de obra durante el Período de Garantía especificado a continuación. Producto Período de garantía lo que ocurra primero: Bombas de chorro, pequeñas bombas centrífugas, bombas 12 meses desde la fecha de la instalación inicial, o...