Summary of Contents for Fancom LUMINA 47 TOUCH

  • Page 1 LUMINA 47 TOUCH LUMINA 47 BLACK BOX MANUAL VERSION C7...
  • Page 2 N.B.: The original, authentic version of this manual is the English version produced by Fancom B.V. or one of its daughter companies (referred to further as Fancom). Any modifications introduced to this manual by third parties have neither been checked nor approved by Fancom. Modifications are taken by Fancom to include translations into languages other than English and the insertion and/or deletion of text and/or illustrations to/from the original contents.
  • Page 3 Lumina 47 Table of contents General introduction ..........................1 How to use this manual ....................... 1 Fancom Sales & Service Center ....................1 F-Central FarmManager™ ......................1 Safety instructions and warnings ....................2 Working ..............................4 User ................................5 Daily management ........................5 Animal management ........................
  • Page 4 For any questions and support, please contact the local Fancom Sales & Service Center. F-Central FarmManager™ Virtually all Fancom equipment can be controlled and managed from a central location. This requires the F- Central FarmManager software package and a communication module. The screens in the control computers are...
  • Page 5 The control computer is a piece of electronic apparatus. There is always a risk of a malfunction occurring. Fancom has made every effort to ensure that an alarm is given in the event of an emergency. Unfortunately, a 100% guaranteed cannot be provided as not all circumstances are under Fancom's control.
  • Page 6 Lumina 47 General introduction When mounting the computer, the following should be observed: Never mount the computer near water pipes, drainage pipes etc. Never mount the computer in a place where the weather has direct influence (not in the sun, or in places where the temperature can rise sharply, etc.).
  • Page 7 Figure 1: Principle of the Lumina 47 (one house with two weighing scales) The Fancom weighing system consists of a computer and a maximum of two weighing scales. The scales are connected to the computer, which can be connected to a PC. The easy to read touch screen clearly shows all relevant information, not only in figures, but also as a descriptive text.
  • Page 8 Lumina 47 User User This section describes a number of user tasks. These are the basic tasks that can be performed using the Lumina Daily management This section contains information about general management. The house management can be assessed quickly using the screen Overview.
  • Page 9 Lumina 47 User Weight data Current data Overview à Readout of the current day number. Weight Readout of the current animal weight. The Lumina 47 re-calculates this value each hour using a special formula. Growth Readout of the daily weight increase per animal. The Lumina 47 re-calculates this value each hour.
  • Page 10 Lumina 47 User Readout of the theoretical animal weight for that day (or week), calculated from the curve. Growth Readout of the weight increase per animal on that day (or week). Unif% Readout of the uniformity percentage or covariance on that day (or week). The readout depends on what has been set.
  • Page 11 Lumina 47 User screen displays the total numbers set up, mortality and delivered. The date of the last change is Animal data shown behind each piece of information. The control computer calculates the data shown as follows: Number of animals present Set up –...
  • Page 12 Lumina 47 User Overview Mortality à à Nbr of animals Setting of the number of removed animals. The total number of removed animals (of today) will appear between brackets. Date Readout of the current date. 3.2.4 Delivering animals When animals are delivered they leave the house. These animals are booked out of the control computer. Animals can also be delivered at intervals.
  • Page 13 Lumina 47 User Animal management Animal management covers all actions which result in a different number of animals: ● Set up animals The control computer will control the climate based on the curve, if a curve is used. At set up enter from which curve day the climate must be controlled.
  • Page 14 Lumina 47 User 3.4.2 Time and date For correct computer functioning, the system time and date must be current. Before making settings, check the system time and date. Overview à Date Setting of the current date. Time Setting of the current time. Setting of the current day number.
  • Page 15 Lumina 47 Installer Installer This section describes the installer displays of the installation menu. Installing the Lumina 47 4.1.1 Determine location Takes into account the following guidelines: 100mm 50mm Figure 2: required edge distances Never place the Lumina 47 in a place where the weather has direct influence (not in the sun, not in places where the temperature can rise sharply etc.).
  • Page 16 Check that the mains voltage and frequency, for which this Fancom controller is suitable (see chapter Technical Specifications in this manual), correspond to the mains voltage and frequency on site.
  • Page 17 Lumina 47 Installer Installing the control computer 4.2.1 Installation menu The installer can configure the control computer using the installation menu. This menu also contains screens for standard system settings and diagnoses. To call up the installation menu: log in to the role Installer. The following installation menu will appear: System SYSTEM 4.3.1...
  • Page 18 Lumina 47 Installer S2S MasterSlave Master/Slave setting. If the control computer is included in a network, only one control computer in the network must be set as MASTER. Set all the other control computers as SLAVE. SYSTEM SYSTEM à tab page Units à...
  • Page 19 Lumina 47 Installer SYSTEM SYSTEM à tab page Sharing à Share animal data Setting for sending or receiving animal data. The control computers in the network can share data. In this way the animal data only has to be entered once, at the sender.
  • Page 20 Lumina 47 Installer Update HI Update HI (HI = Human Interface) loads an operating system (type .HIN) for the keyboard and the screen from the SD-card onto the control computer. Select the required file using the + en – keys on the alpha-numeric keyboard. Confirm using the ENTER key.
  • Page 21 If no IO-net modules are connected, the control computer doesn't give alarms during the Simulation Mode. FNet is the Fancom Network. Several control computers can be linked via this network. FNet is also used to operate the connected control computers from a PC.
  • Page 22 Lumina 47 Installer 4.3.5 IO Test Use the Input (I) and Output (O) test menu to set the control computer to test the communication channels. In the IO-test menu inputs can be readout and outputs controlled at system level. SYSTEM IO TEST à...
  • Page 23 Lumina 47 Installer 4.5.1 Tab page Weighing Weighing à tab page Weighing Address Scale-1 and Scale-2 are connected to address 0.1 respectively 0.2 of the computer. Address 1.1 and higher means that the scales are connected via an I/O module. Description Setting of a suitable name to the scales(s).
  • Page 24 Lumina 47 Installer When the weigher has been calibrated, determine weigher accuracy and carry out any further weigher calibration. The control computer uses the settings below to determine when a measurement is reliable. Filter (second) Setting of the period within which the measured weight must be stable within the limits of the entered differences (Weight stable).
  • Page 25 Lumina 47 System alarms System alarms The table below lists a number of possible alarm reports. The following types of alarm are shown: ● L: Loud alarm ● S: Silent alarm ● S/L: Silent or loud alarm, depending on your settings. ●...
  • Page 26 Relay 1 (alarm relay): voltage free max. 2A 60Vdc/30Vac Communication I/O-Net for extra inputs and outputs using I/O-modules. FNet, Fancom network for intercommunication of control computers and PC connection. Excitation voltage 5 Vdc 2 × Max. input signal 78 mVdc Max.
  • Page 27 Lumina 47 Technical specifications The inside of the control computer...
  • Page 28 Lumina 47 Technical specifications Power supply...
  • Page 29 Lumina 47 Technical specifications IOB.0 Relay 1 Digital output (Alarm relay)
  • Page 30 Lumina 47 Technical specifications I2C connection to IOB Dipswitch I2C address select fixed on address 3 (dipswitch 1-2 on OFF) Weigh input 1 Weigh input 2...
  • Page 31 Lumina 47 Technical specifications 6.4.1 Extending load cell cable The standard cable from the load cells to the Lumina 47 is 10 metres. This cable can be lengthened by maximum 40 metres. When lengthening the cable, follow the diagram below. The standard 4-core cable is lengthened using a 6-core cable as shown in the diagram.
  • Page 32 The control computer and the second I/O network module require a terminal resistor. The first I/O network module is looped. This does not require a terminal resistor. The Fancom Greenlink cable (UTP 1x2x0.8mm, unshielded twisted pair) used to wire the FNET and I/O net. Maximum cable length = 1200 meters.
  • Page 33 Lumina 47 Appendix: EC declaration of conformity Appendix: EC declaration of conformity Manufacturer: Fancom B.V. Address: Industrieterrein 34 City: Panningen (The Netherlands) Hereby declares that the: Lumina 47 Complies with the provisions of the: 1. Low voltage directive 2014/35/EU according to NEN-EN-IEC 61010-1: 2010 2.