Page 1
O P E R A T I N G I N S T R U C T I O N S Dx35 Distance sensor...
Page 2
This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
Modifications and conversions..............Qualification of personnel................ Operational safety and specific hazards..........Warning signs on the device..............UL conformity.................... Product description................12 Product identification via the SICK product ID........Scope of delivery..................Product identification................Display and control elements..............Functions....................Transport and storage............... 16 Transport....................
Page 4
12.8 Repeatability..................... Accessories..................57 Appendix..................... 58 14.1 Menu structure..................O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Page 5
CONTENTS 14.2 Conformities and certificates..............8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Information on this can be found in the operating instructions for the machine or system. Further information You can find the product page with further information via the SICK Product ID: pid.sick.com/{P/N}/{S/N} (see "Product identification via the SICK product ID", page 12).
Page 7
✓ The tick denotes the results of an action. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
The required optical properties of the measuring object are specified in the technical data section of this document. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation.
Page 10
Install the grounding for the product and the system in accordance with national ■ and regional regulations. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
NFPA79 applications only. Adapters including connecting cables are available. More information can be found on the product page: The product page can be accessed via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
The SICK product ID comprises the host name pid.sick.com, the part number (P/N), and the serial number (S/N), each separated by a forward slash. For many products, the SICK product ID is displayed as text and QR code on the type label and/or on the packaging.
There is an error. Check supply voltage, temperature range, EMC disturbances, etc. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Page 14
O = Lights up; Ö = Flashes; o = Does not light up. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
For the DT35 and DL35 models, the Q2 output can be configured as a current output (4 … 20 mA), voltage output (0 … 10 V), or switching output. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Align the light spot so that the desired object is measured. Select and mount the reflector (only for DL35 and DR35) NOTE You can find suitable reflectors and suitable reflective tape at www.sick.com/Dx35. To avoid direct surface reflections, mount the reflector with a tilt of approx. ►...
Perform coarse alignment. To do this, align the distance sensor roughly in the direction of the reflective tape. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Page 19
For DL35 and DR35 device variants, attach large reflective tape for performing the measurement. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
Measures for widely distributed system installations O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
NOTE Pre-assembled cables can be found on the product page. It can be accessed via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if specified).
Page 22
Supply voltage 0 V Q1 / C Black Digital output 1 / IO-Link Gray Multifunctional input (MF) O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
(normally closed contact: switching point logic Low-active), a signal is output (change of output level). 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
Page 24
The LED Q1 farr lights up. Press the set pushbutton. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Page 25
In order to leave teach mode, either press the select pushbutton longer than 5 seconds or wait 5 minutes without pushing the pushbuttons. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
Page 26
Figure 15: Teaching in object between sensor and background (ObSB) (normally open contact) Switching point 1 Tolerance around switching point: ± 25 mm O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Figure 16: Current output signal, 20 mA distance value is greater than the 4 mA distance value Distance value for 4 mA Distance value for 20 mA 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Every time you press the select (–) pushbutton, you move the previously ° taught-in point by –10 mm. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
In order to leave expert mode, press the select and set pushbuttons for longer than 10 seconds or wait 5 minutes without pushing the pushbuttons. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
(Q1 and Q2 LEDs flashing alternately). For a description, see section Teach confirmation O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
A computer with the SOPAS ET software installed on it, and a free USB 2.0 ■ compatible port 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
■ The current version of the SDD file is available for download on the online product page. The product page can be accessed via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
A product-specific device description file (IODD file) is required in the IO-Link master for this purpose. A download package containing the IODD file and supplementary documentation is available at www.sick.com/Dx35. 7.4.3 Service data 7.4.3.1...
Page 34
Content depends on “process data” setting 7.4.3.2 SICK-specific – outputs In the following tables, the factory settings are indicated in bold in the “Value range” and “Example” columns. Table 12: SICK-specific service data – outputs Index decimal Description Format Access...
Page 35
Factory setting for DT35 / DL35 Factory setting for DS35 / DR35 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Page 36
OPERATION 7.4.3.3 SICK-specific – sensor performance Table 13: SICK-specific service data – sensor performance Index decimal Description Format Access Value range Example Note (hex) • 103 (0x67) Response time UINT8 0: Expert Devices up to date code 2033xxxx: Index •...
Page 37
“103”. Factory setting for DT35 / DS35 Factory setting for DR35 / DL35 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Page 38
14: Q2 Analog center • 15: Fine teach +10 mm • 16: Fine teach -10 mm 7.4.3.5 SICK-specific – process data Table 15: SICK-specific service data – process data Index decimal Description Format Access Value range Example Note (hex) • 83 (0x53)
Process data mon‐ UINT16 0 … 50,000 mm Move process data zero itoring point in 1 mm steps. 7.4.3.6 SICK-specific – other settings Table 16: SICK-specific service data – other settings Index decimal Description Format Access Value range Example Note (hex)
The changeover from an inactive to an active state is not delayed. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
This allows you to determine whether the sensor actually makes a measure‐ ment or a contained value is output, even if output of measured values is continuous. Set the alarm function via the index 104. See section SICK-specific service data – other settings.
Page 42
Old center point before centering teach New center point after centering teach O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
ID. The Extended version provides the additional “Timer” process data function. The reverse is also possible. 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
Changing the device ID changes the IO-Link interface. The connection is terminated after the change. A new device search must be started in SOPAS ET. IO-Link master: By adding the appropriate IODD (e.g. SICK-DX35-Extended-xxx-IODD1.1; DeviceID 6488071), the device ID is automatically changed during connection. A device reset sets the device ID back to the default setting.
The following parameters can be configured individually in the Advanced user level and when selecting the Expert speed setting: 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
Page 46
2; 4; 8; 16; 32. The integration or output time remains unchanged. O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Depending on the assignment location, the following preventive maintenance tasks may be required for the device at regular intervals: 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35...
RETURN Return Only send in devices after consulting with SICK Service. ► The device must be sent in the original packaging or an equivalent padded pack‐ ► aging. NOTE To enable efficient processing and allow us to determine the cause quickly, please include the following when making a return: •...
Repair Repairs on the device may only be performed by qualified and authorized personnel from SICK AG. Interference with or modifications to the device on the part of the customer will invalidate any warranty claims against SICK AG. 8014868.1RXV/2025-04-29 | SICK...
Separate the recyclable materials by type and place them in recycling containers. ■ O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
200 mm … 35,000 mm (diamond grade) ### See Reproducibility diagram 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
May not fall short of or exceed U tolerances O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Front screen: acrylic glass (PMMA) Connection type Plug M12, 5-pin Display LEDs 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
(19.7) (26.3) (32.8) (39.4) (46) Distance in m (feet) O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
Page 55
(19.7) (26.3) (32.8) (39.4) (46) Distance in m (feet) 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Page 56
(32.8) (65.6) (98.4) (131.2) (164.1) Distance in m (feet) O P E R A T I N G I N S T R U C T I O N S | Dx35 8014868.1RXV/2025-04-29 | SICK Subject to change without notice...
On the product page you will find accessories and, if applicable, related installation information for your product. The product page can be accessed via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
You can obtain declarations of conformity, certificates, and the current operating instructions for the product at www.sick.com. To do so, enter the product part number in the search field (part number: see the entry in the “P/N” or “Ident. no.” field on the type label).
Page 59
APPENDIX 8014868.1RXV/2025-04-29 | SICK O P E R A T I N G I N S T R U C T I O N S | Dx35 Subject to change without notice...
Page 60
Phone +65 6744 3732 Phone +30 210 6825100 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail office@sick.com.gr E-Mail sales.gsg@sick.com Hong Kong Slovakia Phone +852 2153 6300 Phone +421 482 901 201 E-Mail ghk@sick.com.hk E-Mail mail@sick-sk.sk Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...
Need help?
Do you have a question about the D 35 Series and is the answer not in the manual?
Questions and answers