Sinterit COMPACT SERIES FACILITY PREPARATION GUIDE Please read the manual before using the product. For the most up-to-date manual, visit our website: www.sinterit.com/support/...
4.2.1 Working with hazardous and potentially hazardous powders ..................20 4.3 Fire and explosion protection ..............................20 5. Legal information ................................ 22 5.1 General legal information ................................22 5.2 Disclaimer ....................................22 5.3 Trademarks ....................................22 Sinterit Compact series - Facility Preparation Guide | 2...
All devices listed together with the printers in this manual are optional. If you want to create your Sinterit Compact Set, please contact the Sinterit sales department. • Sinterit is not responsible for a set composed of devices from other companies, even with the same working parameters. •...
Chapter 2 Environmental Requirements. • Please see the table below for the dimensions and total weights of the Compact series packaging. • Each device is a separate package on the pallet with a quick identification label.
Before you will start unpacking remember to leave enough free space around. Multi PHS 2.5 m SANDBLASTER SLS LISA X VACUUM CLEANER SUZY Fig. 1.2 Space considerations when unloading large devices. Sinterit Compact series - Facility Preparation Guide | 5...
2. ENVIRONMENTAL REQUIREMENTS 2.1 General information As standard, besides the printers the Sinterit system includes the Multi PHS, the ATEX/Intertek Vacuum Cleaner and the Sandblaster SLS. Such a set of devices requires: • of space, • smooth floors, • 2 standard power sockets, •...
2.2 Temperature and humidity room requirements It is strongly recommended that the environment, where the Sinterit devices will be installed and operated, match the criteria listed below: Condition Value / Description Storage conditions 5-40 [°C] (41-104 [°F]) Space well-ventilated, with stable temperature and humidity...
Sinterit Devices (Multi PHS, ATEX/Intertek Vacuum Cleaner, Sandblaster SLS and more). WARNING! • When planning the workspace for the Sinterit printer or a whole set, bear in mind escape routes and safety areas! • Do not obstruct escape routes and adapt safety areas to local regulations! 2.3.1 Printer description...
(dry and wet), non-slip, • resistant to solvents. 2.4 Electrical safety Solutions provided by Sinterit are safe for the collection of 3D printing powder. All electrical requirements match the industry standards. WARNING! • Sinterit Lisa X/SUZY printers require a 230 [V] circuit to operate; for customers in 110 [V] regions, we deliver a voltage converter with each such printer.
Aside from the power requirements listed above, an air compressor is also necessary while working with the Sandblaster SLS (part of the integrated Sinterit system). It can also be used to help clean the printer in certain situations, outlined in the manual.
WiFi or via a USB stick - in case the internet connection is not available or barred for security reasons. For optimal performance of the 3D model placement and Sinterit Studio slicing, the recommended system configuration is: •...
The Performance set consists of Lisa X, Multi PHS, the Powder Separator, ATEX / Intertek Vacuum Cleaner and Sandblaster SLS. Fig. 3.1 The clean circulation of SLS powder in the Sinterit system. Sinterit Compact series - Facility Preparation Guide | 13...
The Sinterit Lisa X printer is equipped with a service area, collecting and storing powder dust away from the electronics, where it can be safely disposed of during regular maintenance and cleaning. Multi PHS - uses the rotary effect and gravity - cyclonic separation - to remove solid particles from the air circulating in the system, without the use of filters.
Page 15
Fig. 3.4 Free space considerations while moving between Sinterit devices. IMPORTANT! The devices and arrangements listed below are only a suggestion for the user to help plan the workspace. Purchase of peripherals is optional. Fig. 3.5 Examples of common activities while printing and post-processing, for visual orientation.
Page 16
(3 [m] / ca. 10 [ft]) so that it can always reach wherever it is needed (Fig. 3.7). R = 3 m Fig. 3.7 Optimal placement of the Powder Separator and Vacuum combo. Sinterit Compact series - Facility Preparation Guide | 16...
This will ensure that the amount of movement needed while working isn’t excessive, which could otherwise contribute to powder spills and other accidents. 7.5 m 6.5 m 2700 4300 Footprint: 3000 [mm] Footprint: 3000 [mm] Sinterit Compact series - Facility Preparation Guide | 17...
4.2 Working with powders ATTENTION! • Polyamide powder should be stored in tightly closed containers (e.g. Sinterit metal container), in a room at room temperature and low humidity. • The powder should be stored out of reach of children and pets.
• Use an ATEX-certified explosion-proof vacuum cleaner for all vacuuming or cleaning of the machine from the powder. Sinterit recommends using the ATEX Vacuum Cleaner available in the standard portfolio. • Avoid the accumulation of powder and/or dust in the working area of the machines, their surroundings and accessories.
Page 21
If only possible, disconnect the power from the device. • Match the extinguishing medium and the extinguishing equipment to the general conditions on-site. • Sinterit recommends using Dry Chemical Powder (ABE/BE) or Carbon Dioxide extinguishers for electrical extinguishing devices. WARNING! POWDERS - EXTINGUISHING FIRE •...
5.1 General legal information Where this manual refers to Sinterit or the Company or “us/our”, this means Sinterit sp. z o.o. with its legal seat in Krakow, registered by the District Court for Kraków-Śródmieście in Krakow, XI Commercial Division of the National Court Register under number: 535095, NIP (tax number): 6793106416.
Page 23
SINTERIT Sp. z o.o. ul. Nad Drwina 10/B-3, 30-741 Krakow, Poland www.sinterit.com...