Summary of Contents for Satel BE WAVE Smart HUB Plus
Page 1
BE WAVE system controller Smart HUB Plus Smart HUB Smart HUB Plus LV Firmware version 1.1 smart_hub_en 03/25 SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. +48 58 320 94 00 www.satel.pl...
Page 2
Direct current (DC). Prior to installation, please read carefully the manual. Hereby, SATEL sp. z o.o. declares that the radio equipment type Smart HUB Plus / Smart HUB / Smart HUB Plus LV is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce...
CONTENTS 1. Introduction ........................6 2. Smart HUB Plus / Smart HUB features / Smart HUB Plus LV ........... 6 3. BE WAVE wireless devices ....................7 Smart Keypad (AKP-200) .................... 7 Motion Detector (APD-200) ..................7 Motion Detector Pet (APD-200 Pet) ................8 Motion Detector Cam (APCAM-200) ................
Page 4
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.2.1 Description of the Smart HUB Plus LV controller ..........29 4.2.2 Installation tips for the Smart HUB Plus LV controller ......... 30 4.2.3 Mounting the Smart HUB Plus LV controller ............31 Adding the controller to the Be Wave app ..............
Page 5
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.5.14 Installing the Multi Sensor ................... 78 Installation tips for the Multi Sensor ..............78 Mounting the Multi Sensor .................. 78 4.5.15 Installing the Outdoor Siren ................80 Installation tips for the Outdoor Siren ..............
Page 6
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Enabling the diagnostic mode ................. 113 6. Maintenance ........................113 Firmware update ..................... 113 Replacing the (rechargeable) battery ..............113 6.2.1 Replacing the rechargeable battery in the Smart HUB Plus / Smart HUB / Smart HUB Plus LV controller ................
• Capability to assign devices to 50 rooms. • Up to 50 users. • Be Wave mobile app to manage the system: – communication via the local network or establishing connection through the Internet using the SATEL server, – system programming, – system control, – system diagnostics, –...
• 4 LED indicators. • Built-in sounder. • Powered by: – two LR6 AA 1.5 V batteries (required), – SATEL APS-055 power supply (optional). • Battery status control. Motion Detector (APD-200) It uses infrared to detect motion. • Maximum coverage area: 15 m x 24 m, 90° (see figure below).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Supervision of motion detection system. • Powered by CR123A 3 V battery. • Battery status control. • Tamper protection against enclosure opening and removal from mounting surface.
• Additional transmission channel in the 868 MHz frequency band for the purpose of sending photos. • Built-in temperature sensor (measuring range: -10 °C...+55°C). • LED indicators. • Supervision of motion detection system. • Powered by: – CR123A 3 V battery (required), – SATEL APS-055 power supply (optional).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Battery status control. • Tamper protection against enclosure opening and removal from mounting surface. Motion Detector Plus (APMD-250) It uses infrared and microwaves to detect motion. • Maximum coverage area: 15 m x 24 m, 90° (see figure below).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Outdoor Motion Detector (AOD-210) It uses infrared and microwaves to detect motion. It ignores moving pets up to 20 kilos. It is designed for outdoor installation. • Maximum coverage area: 16 m x 16 m, 90° (see figure below).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Tamper protection against enclosure opening and removal from mounting surface. • Weatherproof enclosure. Curtain Detector (ACD-220) It uses infrared to detect motion in an area shaped like a curtain.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Outdoor Curtain Detector (AOCD-260) It uses infrared and microwaves to detect motion in an area shaped like a curtain. It is designed for outdoor installation. • Maximum coverage area: 10 m x 0.6 m, 6° (see figure below).
You can connect a wired NC detector to it (e.g. a wired opening detector). The built-in opening sensor can be disabled. 3.10.4 Flood detector It detects indoor water flooding. You need to buy the FPX-1 probe by SATEL. 3.10.5 Temperature sensor It measures the air temperature. 3.10.6 Roller shutter detector It detects the opening of a door or window.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Powered by CR123A 3 V battery. • Battery status control. • Tamper protection against enclosure opening and removal from mounting surface. • A magnet for surface mounting and a magnet for flush mounting provided.
– support for NO and NC type detectors, – support for Single EOL and Double EOL configuration. • 4 relay outputs. • Powered by 12 VDC. • Connector for SATEL power supply (e.g. APS-412). • Tamper protection against cover removal. 3.22 Smart Dimmer (ADC-200) It adjusts the brightness of 230 VAC lighting.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – halogen bulbs, – LED bulbs, – light sources powered by an electronic or magnetic transformer. • Automatic recognition of the connected load. • Remote control or local control by means of control inputs.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • 2 control inputs: – capability to connect a double push-button or a roller blind switch, – local blind / shutter control, – capability to control any device in the system.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • 2 control inputs: – capability to connect a double push-button or a switch, – local control of the relay output, – capability to control any device in the system.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Tamper protection against enclosure opening. The repeater does not support the Motion Detector Cam (APCAM-200) and the Outdoor Siren (ASP-200). If a wireless device sends transmissions through the Smart Repeater, its firmware will not be updated remotely.
BEWAVE_AP network), ON in blue – controller is connected to a local network but has no access to the Internet or no connection to the SATEL server, ON in green – controller is connected to the Internet, additionally flashing in yellow –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Figure 2 shows the inside of the Smart HUB Plus / Smart HUB controller after opening the enclosure. tamper protection. power cable port. lithium-ion rechargeable battery (3.6 V / 3200 mAh).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • The BE WAVE wireless devices you are planning to install must be within the range of the controller’s radio communication. Keep this in mind when selecting a place of installation for the controller.
Page 27
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. Drill the holes in the wall for wall plugs (anchors). Use wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
Page 28
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 7. If you want to use two cards, insert the second mini SIM card into the SIM2 slot (Fig. 8) [Smart HUB Plus]. 8. If the controller is to be connected to the wired LAN network, connect the cable to the LAN port (Fig.
Page 29
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 9. Connect the power cable to the power cable port in the controller (Fig. 10) and secure the cable fastener with screws (Fig. 11).
Page 30
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 10. Remove the battery insulator tag (Fig. 12). The controller will power on (the controller LED indicator will start flashing). 11. Close the enclosure and secure it with screws (Fig. 13).
BEWAVE_AP network), ON in blue – controller is connected to a local network but has no access to the Internet or no connection to the SATEL server, ON in green – controller is connected to the Internet, additionally flashing in yellow –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Figure 16 shows the inside of the Smart HUB Plus LV controller after opening the enclosure. tamper protection. 9...28 VDC terminals. lithium-ion rechargeable battery (3.6 V / 3200 mAh).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.2.3 Mounting the Smart HUB Plus LV controller If the controller is to meet the requirements of Standard EN 50131 for Grade 2, mount the controller on the wall.
Page 34
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. Drill the holes in the wall for wall plugs (anchors). Use wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
Page 35
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 9. Screw the power wires to the terminals (Fig. 24) and secure the power wires fastener with screws (Fig. 25).
Page 36
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 10. Remove the battery insulator tag (Fig. 26). The controller will turn on (the controller LED indicator will start flashing). 11. Close the enclosure and secure it with screws (Fig. 27).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Adding the controller to the Be Wave app You can download the Be Wave app from “Google Play” (Android system devices) or “App Store” (iOS system devices). Required Android version: 11 (or newer). Required iOS version: 11 (or newer).
Page 38
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. Tap the controller (site) you want to add. Different buttons will appear at the bottom of the screen. 3. Tap Connect. The New site – Site settings screen will be displayed.
Page 39
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Enter the name of the site and select one of the icons to represent the site, then tap Next. The New site – Admin account screen will be displayed.
Page 40
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL settings. You will return to the New site – Communication methods screen. Tap Save. A screen will be displayed saying that the controller is being prepared to work.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Adding a BE WAVE device to the system Before adding a device that was previously registered to the BE WAVE / ABAX 2 / ABAX system, you must restart it (remove the battery / power the device off for 30 seconds).
Page 42
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. Insert the battery, connect the power, etc. (for detailed information, please refer to the sections on the installation of particular devices), then tap Next. The list of BE WAVE devices detected by the controller will be displayed (the screenshot is an example).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Configure the device settings (enter the name, assign the device to a room and to a group, etc.), then tap Save. A screen will be displayed saying that the device has been added.
We do not recommend installing rechargeable batteries. Optionally, you can connect the SATEL APS-055 power supply (external power supply) to the keypad. The APS-055 is a flush-mounted 5 VDC / 0.5 A power supply. When the power supply is connected to the keypad, the batteries are used only in case of loss of external power supply.
Page 45
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. If the keypad is to be mounted on the wall using a double-sided mounting tape (Fig. 30): – stick the tape to the enclosure base. – if the APS-055 power supply is to be used, run the power wires through the opening in the enclosure base.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Start the Be Wave app and add the keypad to the system. When a request to turn on the device will be displayed, install two LR6 AA 1.5 V alkaline batteries in the keypad.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Do not point the detector towards heat sources (D), air conditioners (E) or fans (F). • No object should obstruct the detector’s field of view. • Install the detector at the recommended height: –...
Page 48
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. If the detector is to be mounted on the wall using a double-sided mounting tape (Fig. 34): – stick the tape to the enclosure base. Adjust the shape and position of the tape depending on the place of installation.
Page 49
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – drill the holes in the wall for wall plugs (anchors). The wall plugs provided with the detector are intended for concrete or brick. For other types of surface (drywall, styrofoam), use other appropriately selected wall plugs.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 5. Use the knob on the cover to enable / disable the creep zone protection (not applicable to the Motion Detector Pet). Fig. 37 A – creep zone protected. Fig. 37 B – creep zone not protected.
COM - common ground. - 5...12 V DC power input. Install a CR123A 3 V battery in the detector. Optionally, you can connect the SATEL APS-055 power supply (external power supply) to the detector. The APS-055 is a flush-mounted 5 VDC / 0.5 A power supply. When the power supply is connected to the detector, the battery is used only in case of loss of external power supply.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Mounting the Motion Detector Cam 1. Open the detector enclosure (Fig. 39). 2. Press the catches and move the electronics module down, then remove it from the enclosure base (Fig. 40).
Page 53
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. If the APS-055 power supply is to be connected to the detector, make a hole in the enclosure base for the power wires (Fig. 41). 4. If the detector is to be mounted on the wall using a double-sided mounting tape (Fig. 42): –...
Page 54
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL The detector must detect removal from the surface if it is to meet the requirements of Standard EN 50131 for Grade 2.
Page 55
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 6. Use the knob on the cover to enable / disable the creep zone protection. Fig. 45 A – creep zone protected. Fig. 45 B – creep zone not protected.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 7. Start the Be Wave app and add the detector to the system. When a request to turn on the device will be displayed, install the battery in the detector.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Mounting the Outdoor Motion Detector 1. Open the detector enclosure (Fig. 48). 2. Remove the electronics module (Fig. 49). 3. Secure the enclosure base with screws to the wall (Fig. 50), to the angle bracket (see...
Page 58
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.). In order for the detector to detect removal from the surface / bracket, fasten the screws in places marked with the symbol in the figure.
Page 59
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – screw the holder with the tamper switch to the enclosure base (Fig. 51-II). The figure shows how to attach the tamper switch in one of the two available positions.
Page 60
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 1. Attach the additional tamper switch: – screw the holder to the tamper switch (Fig. 52-I), – attach the unit making the surface bigger on the tamper switch (Fig. 52-II), –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Drill the holes in the surface for wall plugs (anchors). Use wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
Page 62
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. If the detector is to be mounted on the surface using a double-sided mounting tape (Fig. 54): – stick the tape to the enclosure base. – stick the enclosure base to the surface.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – secure the enclosure base to the surface with screws (Fig. 55). If the detector is to detect removal from the surface, secure the detector with screws. The detector must detect removal from the surface if it is to meet the requirements of Standard EN 50131 for Grade 2.
Page 64
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. Secure the enclosure base to the wall (Fig. 58) or to the bracket mounted on the wall (Fig. 59). The wall plugs provided with the detector are intended for concrete or brick.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.5.7 Installing the Glass Break Detector Installation tips for the Glass Break Detector • The detector should be installed indoors, in spaces with normal air humidity. • Do not install the detector outdoors.
Page 66
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 1. Open the detector enclosure (Fig. 60). The enclosure opening tool, shown in the figure, is provided with the detector. 2. If the detector is to be mounted on the surface using a double-sided mounting tape (Fig.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – drill the holes in the surface for wall plugs (anchors). The wall plugs provided with the detector are intended for concrete or brick. For other types of surface (drywall, styrofoam), use other appropriately selected wall plugs.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Opening detector / Shock and opening detector / Roller shutter detector • Install the detector on the window / door frame (fixed surface). Install the detector in the upper part of the window frame.
Page 69
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 5. If the detector is to be mounted on the surface with screws: – place the enclosure base against the surface and mark the location of the mounting holes.
Page 70
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 7. Opening detector / Shock and opening detector: – if you are connecting a wired NC detector, screw the detector wires to the COM and M1 terminals on the electronics board.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 9. Roller shutter detector: – screw the roller shutter detector wires to the COM and M2 terminals on the electronics board. – if you are connecting a wired NC detector, screw the detector wires to the COM and M1 terminals on the electronics board.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • Install the detector on the window / door frame (fixed surface). Install the detector in the upper part of the window frame. This will reduce the risk of flooding the detector when the window is tilted or open.
Page 73
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL If the detector is to detect removal from the surface, secure the detector with screws. The detector must detect removal from the surface if it is to meet the requirements of Standard EN 50131 for Grade 2.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 6. If you are connecting a wired NC detector, screw the detector wires to the COM and M1 terminals on the electronics board. 7. If you want to disable the built-in opening sensor, use a wire to connect the M2 and COM terminals.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. Close the detector enclosure (note that the cover only fits in one position) and secure it with a screw (Fig. 77). 4. Place the detector on the floor in the selected area.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL bedroom. hall, lobby, etc. kitchen. basement. primary location for detector installation. additional location for detector installation. Mounting the Fire Detector Plus / Fire Detector Pro The figures show the Fire Detector Plus.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – drill the holes in the ceiling for wall plugs (anchors). The wall plugs provided with the detector are intended for concrete or brick. For other types of surface (drywall, styrofoam), use other appropriately selected wall plugs.
Page 78
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 1. Turn the cover counter-clockwise (Fig. 83) and remove it (Fig. 84). 2. If the detector is to be mounted on the wall using a double-sided mounting tape (Fig. 85): –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 6. Press the test / reset button (Fig. 87). An alarm should be generated soon after. The alarm will be signaled by the detector (continuous sound, LED indicator ON). You will receive a notification from the Be Wave app.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Place the detector against the surface and mark the location of the mounting holes. 5. Drill the holes in the surface for wall plugs (anchors). Use wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
Page 81
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 1. Open the detector enclosure (Fig. 91). The enclosure opening tool, shown in the figure, is provided with the detector. 2. If the detector is to be mounted on the surface using a double-sided mounting tape (Fig.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – drill the holes in the surface for wall plugs (anchors). The wall plugs provided with the detector are intended for concrete or brick. For other types of surface (drywall, styrofoam), use other appropriately selected wall plugs.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 6. Secure the enclosure base to the wall with screws. If the siren is to detect removal from the surface, secure also the tamper protection element. 7. Fasten the electronics module in the enclosure base.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. Lift up the cover and remove it (Fig. 97). 3. Place the enclosure base against the wall and mark the location of mounting holes (Fig. 98). If the siren is to detect removal from the surface, mark the location of the hole in the tamper protection element (marked with the symbol in the figure).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Description of the Mini Multi Extender Terminals COM - common ground. +12V - power input. 1...4 - zones Z1...Z4. 5...8 - outputs OUT1...OUT4. The outputs are OC type. When the output is turned off, it is disconnected from the common ground (high impedance).
Page 86
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Taking into account the requirements of the EN 50131-3 standard, select 400 ms when configuring the sensitivity of alarm zones.
4.5.18 Installing the Multi Extender Disconnect power before making any electrical connections. To power the expander, use a 12 VDC power supply (e.g. the SATEL APS-412 power supply). Never connect power supply to APS connector and terminals at the same time.
LED indicators to indicate the status of relay outputs: OFF – output turned off, ON – output turned on. LED indicator to indicate the communication with controller (single flash). APS connector to connect a SATEL power supply (e.g. APS-412). Terminals - common ground. +12V - power input / +12 VDC power output when the expander is powered by a power supply connected to the APS connector.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Installation tips for the Multi Extender • The expander should be installed indoors, in spaces with normal air humidity. • Do not install the expander outdoors. • To connect devices to the expander terminals, use flexible wires with a cross-section of 0.5-0.75 mm...
Page 90
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.5.19 Installing the Smart Dimmer The device should be installed by qualified personnel. Disconnect power before making any electrical connections. Connect the dimmer to a single-phase network according to the applicable standards.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Description of the Smart Dimmer button used to: – register the dimmer in the system – press while adding the dimmer to the system, – block / unblock the registration – press and hold for 10 seconds to block / unblock the capability to add the dimmer to the system.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL • If a magnetic transformer is connected to the dimmer output, make sure the load of the transformer is at least 50% of its rated power. • Do not connect loads higher than 7 A / 150 W to the dimmer.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Do not remove the controller from the enclosure. Installing the controller without enclosure or with a damaged enclosure poses a risk of electric shock and may damage the device.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – 4 single color LED strips, – 4 groups of LED bulbs / halogen bulbs. • The current consumption by the lighting connected to one controller output cannot exceed: –...
Page 96
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.5.21 Installing the Smart Blinds The device should be installed by qualified personnel. Disconnect power before making any electrical connections. Connect the controller to a single-phase network according to the applicable standards.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Wires N [blue] - for connecting 230 VAC supply neutral wire. L [brown] - for connecting 230 VAC supply phase wire. - for connecting the blind / shutter motor – downward motion.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 5. Connect a double push-button / roller blind switch to the controller inputs (Fig. 116). 6. Place the controller in the junction box. Make sure the electrical wires are behind the controller enclosure.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Mounting the Smart Thermostat 1. Remove the thermostat cover (Fig. 117). 2. Start the Be Wave app and add the thermostat to the system. When a request to turn on the device will be displayed, install two LR6 AA 1.5 V alkaline batteries (they are not...
Page 101
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 5. Press the knob (Fig. 119). The thermostat will be calibrated. Mounting on M30x1.5 mm valve 1. Place the thermostat on the valve (Fig. 120). 2. Tighten the thermostat on the valve (Fig. 121).
Page 102
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. If the thermostat is seated loosely on the valve, use the reducer ring. Unscrew the thermostat, place the reducer ring inside its flange (Fig. 122), then repeat points 1 and 2.
Page 103
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 3. Tighten the thermostat on the adapter (Fig. 127). 4. If the thermostat is seated loosely on the valve, use the reducer ring. Unscrew the thermostat, place the reducer ring inside its flange (Fig. 122), then repeat points 2 and 3.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Tighten the thermostat on the adapter (Fig. 133). 5. If the thermostat is seated loosely on the valve, use the reducer ring. Unscrew the thermostat, place the reducer ring inside its flange (Fig. 122), then repeat points 3 and 4.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Installation tips for the Smart Plug • The plug should be installed indoors, in spaces with normal air humidity. • Do not install the plug outdoors. • You can connect a 230 VAC appliance up to 2300 W to the socket (do not use the plug to control appliances whose current consumption is greater than 10 A).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL – block / unblock the registration – press and hold for 10 seconds to block / unblock the capability to add the controller to the system. In variant B, the button is located at the back of the enclosure.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Mounting the Smart 2-CH Relay 1. Power off the circuit to which the controller is to be connected. 2. Open the electrical junction box in which the controller is to be installed.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4.5.25 Installing the Smart Switch Controller Description of the Smart Switch Controller battery holder cover (CR14250 3 V). Use a screwdriver to remove the cover (Fig. 139). button used to: –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 5. Place the module in the junction box. Make sure the wires are behind the module enclosure. 6. Close the junction box. 4.5.26 Installing the Smart Button Installation tips for the Smart Button •...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Mounting the Smart Button 1. Open the button enclosure (Fig. 142). 2. Stick the double-sided mounting tape to the enclosure base. 3. Stick the enclosure base to the surface.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Description of the Smart Repeater The figure shows the inside of the repeater after removing the cover. RS-232 (TTL) port – unused. rechargeable battery. tamper switch. battery connector.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL vertically, diagonally). Before you install the repeater, check in which position the range of the repeater is the best. • The repeater should be permanently connected to the 230 VAC mains supply.
Page 113
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 4. Drill the holes in the wall for wall plugs (anchors). Use wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 10. Connect the battery to the connector (Fig. 149). The repeater will start up. 11. Replace the cover and lock it with a screw. 12. Power on the circuit to which the repeater is connected.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Enabling the diagnostic mode 1. Tap the icon. 2. Tap Diagnostics > Enable diagnostic mode. All devices will enter the diagnostic mode after some time (up to 24 seconds).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. Open the controller enclosure. 3. Remove the old battery (Fig. 150). 4. Install the new battery (Fig. 151). 5. Close the enclosure and secure it with screws.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 2. Tap the name of the low battery siren. 3. Tap Battery replacement. 4. After the leftmost LED on the siren starts flashing every 3 seconds, you can open the siren enclosure.
Page 118
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 6. For the Fire Detector Plus, remove the plastic element with the thermistor from the smoke chamber cover (Fig. 156). 7. Release the mounting catch (Fig. 157) and remove the smoke chamber cover (Fig. 158).
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 15. Press again the test / reset button to clear the alarm. 16. Disable the diagnostic mode in the Be Wave app. Restoring the controller factory settings 6.4.1 Restoring the factory settings from the Be Wave app 1.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 7. Using the Smart Keypad LED indicators Color Description ON – diagnostic mode is enabled blue flashing – trouble or trouble memory yellow ON – system is armed green flashing –...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Keys Functions of keys touch to enter a digit (for access code) touch to clear the entered code enter access code and touch to arm the system / disarm the system / clear alarm...
– when entry delay signaling is over, – after 60 seconds of alarm signaling. The keypad will not go to sleep if it is powered from a power supply (SATEL APS-055 power supply). The LED indicators, backlight and sound signaling are enabled all the time.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 9. Manual control of the devices Manual control of the Smart Thermostat LED display. knob. 9.1.1 LED display Normally, the display is off. Touch the knob (Fig. 119) to turn on the display.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Boost Heat is enabled (number at the end is the minutes remaining until the end of the function). If you want to stop the Boost Heat, press and hold the knob for 3 seconds.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 1. Press the knob to turn on the display. 2. Press the knob to display the currently set temperature. 3. Turn the knob to set the new temperature.
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL 10. Specifications 10.1 Smart HUB Plus / Smart HUB Operating frequency band..............868.0 MHz ÷ 868.6 MHz Radio communication range (in open area) ............up to 2000 m Supply voltage ....................
Dimensions ....................45 x 128 x 21 mm Weight ..........................75 g Hereby, SATEL sp. z o.o. declares that the radio equipment type AKP-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.4...
Dimensions ....................62 x 137 x 42 mm Weight ..........................132 g Hereby, SATEL sp. z o.o. declares that the radio equipment type APD-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.5...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Hereby, SATEL sp. z o.o. declares that the radio equipment type APD-200 Pet is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce...
Dimensions ....................62 x 137 x 42 mm Weight ..........................152 g Hereby, SATEL sp. z o.o. declares that the radio equipment type APMD-250 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.8...
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Hereby, SATEL sp. z o.o. declares that the radio equipment type AOD-210 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.9...
Dimensions ....................44 x 105 x 40 mm Weight ..........................118 g Hereby, SATEL sp. z o.o. declares that the radio equipment type AOCD-260 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.11 Glass Break Detector (AGD-200)
This range is for reference only. Please test the actual range when mounting the detector. Hereby, SATEL sp. z o.o. declares that the radio equipment type AXD-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce...
Flush mounted magnet enclosure dimensions ............ø10 x 28 mm Weight ..........................59 g Hereby, SATEL sp. z o.o. declares that the radio equipment type AXD-200 Lite is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce...
SATEL Weight ..........................172 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ASD-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.16 Fire Detector Pro (ASD-250)
Dimensions ......................ø108 x 54 mm Weight ..........................153 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ACMD-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.18 Outdoor Dusk Detector (ADD-200)
Dimensions ....................58 x 115 x 34 mm Weight ..........................95 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ADD-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.19 Multi Sensor (ATPH-200)
Dimensions ....................148 x 254 x 64 mm Weight ..........................762 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ASP-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.21 Indoor Siren (ASP-215)
Dimensions ...................... 21 x 41 x 13 mm Weight ..........................10 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ACX-210 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.23 Multi Extender (ACX-220)
Dimensions ..................... 47 x 47 x 22 mm Weight ..........................33 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ADC-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.25 Smart RGBW LED Driver (ARC-200)
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Hereby, SATEL sp. z o.o. declares that the radio equipment type ARSC-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.27 Smart Thermostat (ART-210)
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Hereby, SATEL sp. z o.o. declares that the radio equipment type ASW-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.29 Smart 2-CH Relay (ASW-210)
Smart HUB Plus ● Smart HUB ● Smart HUB Plus LV SATEL Hereby, SATEL sp. z o.o. declares that the radio equipment type APT-210 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce 10.31 Smart Switch Controller (ATX-200)
Enclosure dimensions ................. 126 x 158 x 32 mm Weight ..........................265 g Hereby, SATEL sp. z o.o. declares that the radio equipment type ARU-200 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity...
Need help?
Do you have a question about the BE WAVE Smart HUB Plus and is the answer not in the manual?
Questions and answers