Page 1
ABAX WIRELESS SYSTEM CONTROLLER ACU-250 Firmware version 4.03 acu-250_en 02/14 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu...
Page 2
Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty. The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical specifications and firmware. The current information on the introduced modifications is available on our website.
CONTENTS General..........................2 Features ........................... 2 Electronics board ......................2 Installation of the controller....................2 Programming the controller ....................4 Parameters, options and functions ................4 Wireless devices supported by the controller ..............6 Installation of wireless devices ..................6 Work with the INTEGRA / INTEGRA Plus control panels.......... 7 7.1.1 Adding new wireless devices................
SATEL 1. General The ACU-250 controller works with the INTEGRA, INTEGRA Plus and VERSA control panels. It enables expansion of the security alarm system by adding the ABAX wireless devices. The ABAX system is based on two-way communication. All transmissions are acknowledged, which ensures that the information has been received and makes it possible to check the presence of devices in the system in real time.
Page 5
SATEL ACU-250 The controller should be installed indoors, in spaces with normal air humidity. Prior to installation you should plan the arrangement of all ABAX system wireless devices which are to be operated by the controller. When selecting the controller installation place, make sure that all these devices will be located within its operating range.
9. Turn on the power of the alarm system. 10. Start the identification function in the control panel. The ACU-250 controller will be identified as ACU-100 and this name will be assigned to it by default by the control panel.
Page 7
SATEL ACU-250 In the case of the AMD-103 detector, no communication takes place during polling. Higher sensitivity for jamming detection – if this option is enabled, the sensitivity of detection of radio communication jamming is boosted. Synchronize – this function starts the procedure of synchronization, i.e. checking for presence of other ABAX wireless system controllers working within the controller operating range.
(see: Table 2). In such a case, it is recommended that the last devices be removed from the list and then added to the system again, so as to fill up the gap in the list and reduce the number of zones reserved for wireless devices. INTEGRA / INTEGRA Plus ACU-100 / ACU-250 zones outputs It..
SATEL ACU-250 identification procedure will be impossible. It will be necessary to change addresses of the devices connected to the bus. 7.1.1 Adding new wireless devices For some wireless devices, you can select whether the device will take up one or two positions (channels) on the list of devices.
ACU-250 SATEL 3. When the "Open device tamper" command is displayed: power on the ACX-200 or ACX-201 expander module, turn on the ARF-100 tester, insert the ASW-100 E / ASW-100 F wireless controller into 230 V AC socket, ...
SATEL ACU-250 4. The device will be removed. A message on the display will inform you that the expander identification function has been started. 5. After identification of the devices, return to the list o f wireless devices will follow.
ACU-250 SATEL APMD-150 – wireless dual motion detector. The following is to be programmed: sensitivity of PIR sensor; sensitivity of microwave sensor; the way of o peration in test mode. APD-100 – wireless passive infrared detecto r. The following is to be programmed: ...
Page 15
SATEL ACU-250 relating to wireless devices are not read and saved after clicking on the button in the X program main menu). LOAD In the "ARU" column: – leave the field blank, if the device is to communicate directly to the controller;...
ACU-250 SATEL digit – maximum duration of acoustic signaling: 1 (1 minute), 2 (3 minutes), 3 (6 minutes) or 4 (9 minutes). -205 – for both positions taken on the list by the siren, enter 3 digits: digit – maximum duration of signaling: 1 (1 minute), 2 (3 minutes), 3 (6 minutes) or 4 (9 minutes).
SATEL ACU-250 Wireless detectors The wireless detectors send information on violations, tampers and low-battery status. The information on violations and tampers is sent to the zones to which the detectors are assigned. The system zones to which the wireless detectors are assigned can be programmed as: ...
ACU-250 SATEL the control panel outputs which control the siren must be longer than the response period. It is recommended that cut-off time correspond to maximum duration of signaling programmed for the siren. The zones in the system to which the wireless sirens are assigned can be programmed as: ...
SATEL ACU-250 Additionally, the ACX-201 expander module sends information about: status of AUX1 and AUX2 power supply outputs – information on overload is sent when the AUX1 or AUX2 output load exceeds 0.5 A. battery status – information on low battery is sent when the battery voltage drops below 11 V for more than 12 minutes (3 battery tests).
Page 20
ACU-250 SATEL (or two buttons simultaneously) will violate the zone and cause suitable reaction from the control panel. On pressing any keyfob button (not necessarily the one used to control a system zone), information on the status of three selected system outputs will be presented on the keyfob LEDs.
SATEL ACU-250 10.1.1 Adding the APT-100 keyfob by means of the program LOAD Entering the serial number manually 1. Click on the field in the "S/N" column next to the name of the user to whom you want to assign a keyfob.
ACU-250 SATEL clicking on the button or saved after clicking on the button in the D LOAD program main menu). Removal of a keyfob by means of the keypad will not erase its settings (the functions assigned to the buttons). When added to the user, the new keyfob will have the same settings as the deleted one.
SATEL ACU-250 Security grade according to EN50131-3 ............... Grade 2 Complied with standards..EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-3, EN 50131-5-3 Environmental class according to EN50130-5 ................. II Operating temperature range................-10 °C...+55 °C Maximum humidity ......................93±3% Enclosure dimensions..................24 x 110 x 27 mm Weight..........................
Need help?
Do you have a question about the ACU-250 and is the answer not in the manual?
Questions and answers