Banner IC70-16P-K Product Manual

In-cabinet io-link hub

Advertisement

Quick Links

IC70-16P-K In-Cabinet IO-Link Hub
Product Manual
Original Instructions
p/n: 246946 Rev. A
27-Feb-25
© Banner Engineering Corp. All rights reserved. www.bannerengineering.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC70-16P-K and is the answer not in the manual?

Questions and answers

Summary of Contents for Banner IC70-16P-K

  • Page 1 IC70-16P-K In-Cabinet IO-Link Hub Product Manual Original Instructions p/n: 246946 Rev. A 27-Feb-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com...
  • Page 2: Table Of Contents

    Dimensions ........................................21 Chapter 7 Accessories......................22 IC70 Cordsets......................................22 Chapter 8 Product Support and Maintenance ..............24 Resources ........................................24 Repairs ........................................24 Contact Us ........................................24 Banner Engineering Corp Limited Warranty..............................24 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com...
  • Page 3: Chapter 1 Features

    24 V DC rail, allowing you to use multiple 24 V DC sources if needed or supply power to a nearby device. The IC70-16P-K In-Cabinet IO-Link Hub connects 16 PNP inputs as Process Data In and 16 PNP outputs as Process Data Out. Use an IO-Link master device to monitor and configure the I/O channels.
  • Page 4: Chapter 2 Configuration

    For the latest IO-Link protocol and specifications, please visit www.io-link.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. 27-Feb-25 © Banner Engineering Corp. All rights reserved.
  • Page 5: Chapter 3 Mechanical Installation

      IC70-16P-K In-Cabinet IO-Link Hub Product Manual Chapter Contents Wiring ........................................... 5 Chapter 3 Mechanical Installation Install the IC70 to allow access for functional checks, maintenance, and service or replacement. Do not exceed the operating specifications for reliable operation. The enclosure must provide adequate heat dissipation so that the air closely surrounding the IC70 does not exceed its maximum operating temperature.
  • Page 6 IC70-16P-K In-Cabinet IO-Link Hub Product Manual Mechanical Installation I/O Channels Left Power Right Power Channels Channels The left and right power channels are tied internally to screw terminals 1–3 on the power supply screw terminals. page 6 of 25 © Banner Engineering Corp. All rights reserved. 27-Feb-25 www.bannerengineering.com...
  • Page 7: Chapter 4 Operating Instructions

    Chapter 4 Operating Instructions Status Indicators The IC70-16P-K In-Cabinet IO-Link Hub has 16 amber LEDs to indicate discrete I/O status. There is also an additional amber LED specific to the IO-Link communications and a green power indication LED. IC70-16P-K CHANNEL...
  • Page 8: Chapter 5 Io-Link Data Reference Guide

    Parameters Set Using IO-Link.................................... 10 IO-Link Events........................................19 Chapter 5 IO-Link Data Reference Guide This document refers to the following IODD file: Banner_Engineering-IC70-16P-K-20241101-IODD1.1.xml. The IODD file and support files can be found on www.bannerengineering.com under the download section of the product family page.
  • Page 9: Process Data Out (Master To Device)

    IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Octet 0 Subindex Bit offset Value Octet 1 Subindex Bit offset Value Example based on the listed values Channel 1 input state active Channel 9 input state inactive Channel 2 input state...
  • Page 10: Parameters Set Using Io-Link

    Parameters Set Using IO-Link These parameters can be read from and/or written to an IC70-16P-K IO-Link Hub. Also included is information about whether the variable in question is saved during data storage and whether the variable came from the IO-Link Smart Sensor Profile.
  • Page 11 IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Continued from page 10 Access Data Index Subindex Name Length Value Range Default Rights Storage? 32-bit Run counter 0..2147483647 Uinteger Resettable Run Time 32-bit Run counter 0..2147483647 Uinteger All-Time Run Time Event...
  • Page 12 IC70-16P-K In-Cabinet IO-Link Hub Product Manual IO-Link Data Reference Guide Continued from page 11 Access Data Index Subindex Name Length Value Range Default Rights Storage? 32-bit Channel 6 Events per Minute 1..300000 Uinteger 32-bit Channel 6 Totalizer Counter 0..2147483647 Uinteger...
  • Page 13 IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Continued from page 12 Access Data Index Subindex Name Length Value Range Default Rights Storage? 32-bit Channel 13 Totalizer Counter 0..2147483647 Uinteger 32-bit Channel 14 Count 0..2147483647 Uinteger 32-bit Channel 14 Duration 0..2147483647, 50µS resolution...
  • Page 14 IC70-16P-K In-Cabinet IO-Link Hub Product Manual IO-Link Data Reference Guide Continued from page 13 Access Data Index Subindex Name Length Value Range Default Rights Storage? 32-bit Channel 7 Reset Count 0..2147483647 Uinteger 32-bit Channel 8 Reset Count 0..2147483647 Uinteger 32-bit Channel 9 Reset Count 0..2147483647...
  • Page 15 IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Continued from page 14 Access Data Index Subindex Name Length Value Range Default Rights Storage? 0 = Disabled, 1 = On Off Delay, 2 = On One- shot, 3 = Off One-shot, 4 = On Pulse-...
  • Page 16 IC70-16P-K In-Cabinet IO-Link Hub Product Manual IO-Link Data Reference Guide Continued from page 15 Access Data Index Subindex Name Length Value Range Default Rights Storage? 32-bit 0..2147483647 (Channel Off Delay or Delay Timer 2 Uinteger Totalizer time)ms Mirroring Enable 8-bit Uinteger...
  • Page 17 IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Continued from page 16 Access Data Index Subindex Name Length Value Range Default Rights Storage? 0=Channel 1, 1=Channel 2, 2=Channel 3, 3=Channel 4, 4=Channel 5, 5=Channel 6, 6=Channel 7, 7=Channel 8, 8=Channel 9,...
  • Page 18 IC70-16P-K In-Cabinet IO-Link Hub Product Manual IO-Link Data Reference Guide Continued from page 17 Access Data Index Subindex Name Length Value Range Default Rights Storage? Channel 13 Configuration IO Selection 8-bit Uinteger 1=PNP Input, 3=PNP Output with Pull Down 0 = Disabled, 1 = On Off Delay, 2 = On One-...
  • Page 19: Io-Link Events

    IO-Link Data Reference Guide IC70-16P-K In-Cabinet IO-Link Hub Product Manual Continued from page 18 Access Data Index Subindex Name Length Value Range Default Rights Storage? 0 = Disabled, 1 = On Off Delay, 2 = On One- shot, 3 = Off One-shot, 4 = On Pulse-...
  • Page 20: Chapter 6 Specifications

      IC70-16P-K In-Cabinet IO-Link Hub Product Manual Chapter Contents FCC Part 15 Class B for Unintentional Radiators .............................. 20 Industry Canada ICES-003(B).................................... 20 Dimensions......................................... 21 Chapter 6 Specifications Supply Voltage Construction 18 V DC to 30 V DC at 400 mA maximum (exclusive of load) Hub Base: black plastic polybutylene terephthalate (PBT)
  • Page 21: Dimensions

    Specifications IC70-16P-K In-Cabinet IO-Link Hub Product Manual Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. 27-Feb-25 © Banner Engineering Corp. All rights reserved. page 21 of 25 www.bannerengineering.com...
  • Page 22: Chapter 7 Accessories

      IC70-16P-K In-Cabinet IO-Link Hub Product Manual Chapter Contents IC70 Cordsets ........................................22 Chapter 7 Accessories IC70 Cordsets 4-pin Single-Ended M12 Male Cordsets Model Length Dimensions (mm) Pinout (Male)   BC-M12M4-22-1 1 m (3.28 ft) M12X1 BC-M12M4-22-2 2 m (6.56 ft) Ø14.5 mm...
  • Page 23 Accessories IC70-16P-K In-Cabinet IO-Link Hub Product Manual 4-pin Single-Ended M12 Female Right-Angle Cordsets Model Length Dimensions (mm) Pinout (Female)   32 Typ. BC-M12F4A-22-1 1 m (3.28 ft) [1.26"] BC-M12F4A-22-2 2 m (6.56 ft) BC-M12F4A-22-5 5 m (16.4 ft) 30 Typ.
  • Page 24: Chapter 8 Product Support And Maintenance

    Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
  • Page 25 LinkedIn X (formerly Twitter) Facebook © 2025. All rights reserved. www.bannerengineering.com...

Table of Contents