localityname
string[128]
organizationna
string[64]
me
unit
string[32]
commonname
string[64]
validdays
0 ~ 9999

Query status of the digital input

Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
where <state> can be 0 or 1.
Example: Query the status of digital input 1
Request:
http://myserver/cgi-bin/dido/getdi.cgi?di0
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: 7\r\n
\r\n
di0=1\r\n
6/6
the locality name in certificate information
6/6
organization naem in certificate information
6/6
organizational unit name in certificate information
6/6
common name in certificate information
6/6
certificatation valid period