Any temporary personnel must be supervised by skilled users. The order of execution of operations defined in this manual must be absolutely respected. Store this manual next to the pump so that it can be consulted at any time. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 3 ...
The product is then successively sucked and pushed due to the wheel rotation. 4 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
3 .7 - AVAILABLE OPTIONS ALBIN PUMP offers several options for their pumps: - Hose rupture detector. - Revolution-counter. Please contact your ALBIN PUMP distributor for any information about these different options 6 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
- It is recommended to install a flexible line to help absorb pulsation. During the pump ground study, provide enough space for the hose change. Distance (L) is the required length for hose removal. DIMENSIONS mm (inch) PUMP ALX150 2500 (98.4) Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 7 ...
Start the pump by checking its direction of rotation by the front cover. d. Check the flow and discharge pressure and adjust rollers if these figures don’t match the pump specifications. 8 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
CAUTION! Never run the pump without the front bracket and front cover front cover fully secured. Free Roller Pressing roller Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 9 ...
Blocked roller Adjust this roller to Free roller Lossen the correct dimension . bracket screws 4 x Screw NOTE : Contact the factory for hose change-out instructions based on your specific pump configuration. 10 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
Hoses must be stored sheltered from light in a cool place. The hose life is reduced after two years. The performance of hoses is reduced at the end of this expiration date due to the aging of rubber. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 11...
/hr = 22.0143 gpm 1 rev = 83.3333 L = 22.0143 gal *Intermittent use : minimum one hour stop after 2 hours run / *Occasional use : maximum one hour a day Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 13 ...
9 .3 - NOMENCLATURE EXPLODED VIEW ALX150 ITEMS 300, 302, 304, 306, 307, 308, 309, 310 AND 311 ARE REFERENCE (POSITION) IN THE LIST IS NOT CONSISTENT WITH THE REFERENCE (POSITION) IN ORATIO. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 15 ...
The cover and the pump casing can become very hot due to the friction on the hose and liquid temperature. If you need to limit the pump temperature, please contact your ALBIN PUMP distributor. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 17 ...
CENELEC relating to the electric materials usable in explosive atmospheres of group II. From this date, the accessories or (and) component assembled equipping the motors with our pumps must have an EEC examination certificate. 18 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
Page 19
9 .3 ATEX characteristics of the motor or the motor reducer of the pump 10 - ATEX characteristics of the pumping installation 11 - Security form 12 - Pumping vat of retention 13 - Marking of the pump Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 19 ...
Page 20
(T) of the pump. The threshold of release of the temperature sensor will have to be adjusted from 0°C (32°F) to 75°C (165°F) more or less 5°C (41°F), with a 10°C (50°F) hysteresis. 20 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
Page 21
Nevertheless, dry running is not a normal function of the pump and if it doesn’t directly constitute a risk of ignition, it leads to premature wear and tear of the hose. This type of function must be limited as much as possible. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 21 ...
Page 23
Thus, the adjustment of the low point of the tank will have to be higher than the opening of the suction pipe. That will always result in the presence of liquid and not of gas and liquid. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 23 ...
Page 24
ALBIN: TYPE ALX II 2G Ex h II C T4 Gb N° series: Year ....In the case of a pumping group, ATEX certified materials will retain their original markings. 24 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
5 .0 Signatory authorized Signed ___________________ Name ___________________ Position __________________ Date ___________________ Remarks: to assist us in our servicing please describe any fault condition you have witnessed. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 25 ...
We declare under our responsibility that the equipment defined in section 1.0 satisfies in all the directives of the European Community specified in section 2.0 and in the French work legislation. Date: XX XXX XXXX Thomas Mapelli 26 albinpump@irco.com Albinpump.com Albin Pump ALX Instruction Manual ...
Page 27
Ensure that all protections have been made regarding this aspect. Before each use, check the direction of rotation of the pump. While placing the pump under vacuum, mount window screws using an airtight glue to avoid air leakage. Albin Pump ALX Instruction Manual Albinpump.com albinpump@irco.com 27 ...
Page 28
Distributed by: albinpump@irco .com www .albinpump .com About Ingersoll Rand Inc. Albin Pump is a brand of Ingersoll Rand and part of the Precision and Science Technologies (PST) business segment. PST consists of a portfolio of complementary, mission critical brands such as Milton Roy®, ARO®, LMI®, Albin Pump, Thomas®, Welch®, Haskel®, Dosatron®, YZ®, Williams®, MP®...