SICK KTS Core EasyTeach 4-PIN RGB LED Operating Instructions Manual
SICK KTS Core EasyTeach 4-PIN RGB LED Operating Instructions Manual

SICK KTS Core EasyTeach 4-PIN RGB LED Operating Instructions Manual

Contrast sensor

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
KTS Core
Contrast sensor
4-PIN RGB LED EasyTeach

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KTS Core EasyTeach 4-PIN RGB LED and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK KTS Core EasyTeach 4-PIN RGB LED

  • Page 1 O P E R A T I N G I N S T R U C T I O N S KTS Core Contrast sensor 4-PIN RGB LED EasyTeach...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Possible errors during commissioning............ Possible errors during operation............. Maintenance..................23 Maintenance..................... 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 4 13.1 EU declaration of conformity and certificates........13.2 Certification according to UL 60947-5-2..........13.3 Licenses....................O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 5: About This Document

    … indicates a situation of imminent danger, which will lead to a fatality or serious injuries if not prevented. 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core...
  • Page 6: Further Information

    Before calling, make a note of all type label data such as type code, serial number, etc., to ensure faster processing. O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 7: Safety Information

    The system designer must provide measures to ensure the safety of persons and systems in accordance with the legal guidelines. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 8: Requirements For Skilled Persons And Operating Personnel

    SICK AG. O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK...
  • Page 9: Product Description

    The SICK product ID comprises the host name pid.sick.com, the part number (P/N), and the serial number (S/N), each separated by a forward slash. For many products, the SICK product ID is displayed as text and QR code on the type label and/or on the packaging.
  • Page 10: Product Features And Functions

    M5 threaded mounting hole Display M5 threaded mounting hole Light emission O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 11 Monitoring of wafer surfaces • Roll end monitoring 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 12: Mounting

    Ensure that any sensor movement does not affect the sensing distance. O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 13 To secure a stable detection when having high gloss material a tilt angle of 10°-15° might be necessary. 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core...
  • Page 14: Electrical Installation

    If these instructions are not complied with, the IP enclosure rating for the device is not guaranteed! O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 15: Note On The Swivel Connector

    "Pin assignment of the connections", page Voltage level at the input starts the corresponding function of the device. 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core...
  • Page 16 + (L+) push-pull (≤ 100 mA) ‒ (M) ‒ (M) O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 17: Commissioning

    Excellent detection reliability Good detection reliability Poor detection reliability 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 18 Table 3: Quality of Run indicator Indication Meaning O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 19: Operation

    The following teach-in process is available for configuring the device: • Dynamic teach-in 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 20 Deactivate teach-in via the control cable (ET). The teach-in process is complete. O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 21: Other Indicators And Functions

    Any settings made which have not been confirmed are not adopted. To quit standby mode, one of the operating keys must be pushed. 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core...
  • Page 22: Troubleshooting

    • Manual switching thresh‐ again old set incorrectly O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 23: Maintenance

    ► NOTE Static charge may cause dust particles to stick to the light emission window. This effect can be avoided by using an anti-static glass cleaner in combination with the SICK lens cloth (can be obtained from www.sick.com). NOTE If the light emission window is scratched or damaged (cracked or broken), the device must be replaced.
  • Page 24 O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 25: Decommissioning

    This symbol on the product, its package or in this document, indicates that a product is subject to these regulations. 10.2 Returning devices Do not dispatch devices to the SICK Service department without consultation. ► NOTE To enable efficient processing and allow us to determine the cause quickly, please...
  • Page 26: Technical Data

    Operation in short-circuit protected network max. 8 A O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 27: Dimensional Drawings

    Connector M12, mechanical stop rechts Connector M12, mechanical stop left Control panel 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 28 Connector M12, mechanical stop rechts Connector M12, mechanical stop left Control panel O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 29 Connector M12, mechanical stop rechts Connector M12, mechanical stop left Control panel 8021268.1P18/2025-02-25 | SICK O P E R A T I N G I N S T R U C T I O N S | KTS Core Subject to change without notice...
  • Page 30: Accessories

    Accessories can be found on the online product page at: www.sick.com/KTS ► www.sick.com/KTX ► O P E R A T I N G I N S T R U C T I O N S | KTS Core 8021268.1P18/2025-02-25 | SICK Subject to change without notice...
  • Page 31: Annex

    13.3 Licenses SICK uses open-source software. This software is licensed by the rights holders using the following licenses among others: the free licenses GNU General Public License (GPL Version2, GPL Version3) and GNU Lesser General Public License (LGPL), the MIT license, zLib license, and the licenses derived from the BSD license.
  • Page 32 Phone +65 6744 3732 Phone +30 210 6825100 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail office@sick.com.gr E-Mail sales.gsg@sick.com Hong Kong Slovakia Phone +852 2153 6300 Phone +421 482 901 201 E-Mail ghk@sick.com.hk E-Mail mail@sick-sk.sk Detailed addresses and further locations at www.sick.com SICK AG  |  Waldkirch  |  Germany  |  www.sick.com...

This manual is also suitable for:

Ktx core easyteach 4-pin rgb ledKts core 4-pin rgb led

Table of Contents