1-Year Warranty 55 2.2.1. Install Software Ordering Information 55 2.2.2. Setup Com Port and IP Address 2.2.3. Assign Static IP Address Contact MaxStream 56 2.2.4. Change Com Port Number 2.2.5. Test Communications (X-CTU) 2.3. Telnet Communications 12 2.3.1. Test Communications (Telnet) 3.
1.1.1. Worldwide Acceptance FCC Certified (USA) Refer to Appendix A for FCC Requirements. Systems that contain XStream RF Modems automatically inherit MaxStream Certifications. ISM (Industrial, Scientific & Medical) frequency band Manufactured under ISO 9001:2000 registered standards 9XStream-PKG-E (900 MHz) RF Modems approved for use in US, Canada, Australia, Israel (and more).
2.1.1. System Description The PKG-E Ethernet RF Modem can be used as an access point in a network of MaxStream RS- 232/RS-485 RF Modems (or other OEM RF Module Embedded Devices). XStream RF Modems support point-to-point, peer-to-peer, point-to-multipoint and multidrop network topologies.
To Install the X-CTU Software: Double-click the “setup_X-CTU.exe” file then follow prompts of the installation screens. This file is located on the MaxStream CD and under the ‘Downloads’ section of the following web page: www.maxstream.net/support/. Installation #2: Ethernet Com Port Redirector MaxStream provides com port redirection software that creates a com port in the operating system that will forward serial data to the IP address of the Ethernet-connected RF modem.
XStream‐PKG‐E™ Ethernet RF Modem – Product Manual v5.x00 [2006.02.24] 2.2.5. Test Communications (X-CTU) When testing a wireless link, MaxStream suggests creating the link using the following components: • XStream-PKG-E Ethernet RF Modem (connected to a local network) • XStream-PKG-R RS-232/485 RF Modem (w/ loopback adapter) • PC (connected to a local network) •...
2.3. Telnet Communications In addition to com port communications, Telnet communications are also supported. 2.3.1. Test Communications (Telnet) MaxStream Wireless links can be tested by connecting to the specific IP address and port number. Test a Wireless Link (Telnet Connection): Follow steps in the “Ethernet RF Modem Discovery”...
Page 14
UART after the transmission began. If more data is pending, the transmitting modem assembles a subsequent packet for transmission. RF Data Packet The RF packet is the sequence of data used for communicating information between MaxStream Modems. An RF Packet consists of an RF Initializer and RF Data. Figure 3‐03. RF Data Packet Components ...
XStream‐PKG‐E™ Ethernet RF Modem – Product Manual v5.x00 [2006.02.24] 4. RF Modem Configuration 4.1. Hands-On Programming Examples For more information about entering Command Mode, sending Examples in this section commands and exiting Command Mode, refer to the Command Mode cite the use of MaxStream’s section [p18]. X‐CTU Software for 4.1.1. Configuration Setup Options programming the RF modem. Other programs After installing the X-CTU and Com Port Redirector Software [refer to such as Telnet Software ...
ID (Modem VID) Command <Networking> Read the modem’s VID. VID is a AT Command: ATID MaxStream-specific acronym that stands for Binary Command: 0x27 (39 decimal) “Vendor Identification Number”. This number is Parameter Range (user-settable):...
Acknowledged Mode [p44], Multi-Streaming Mode [p46] Peer-to-Peer Modems remain synchronized without use of a master/server. Each modem shares the roles of master and slave. MaxStream’s peer-to- Definition peer architecture features fast synch times (35ms to synchronize modems) and fast cold start times (50ms before transmission).
IMPORTANT: The 9XStream (900 MHz) and 24XStream (2.4 GHz) RF Modems have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Changes or modifications not expressly approved by MaxStream could void the user’s authority to operate the equipment.
This test is called the Specific Absorption Rate (SAR) testing and measures the emissions from the radio modem and how they affect the person. Over 100 additional antennas have been tested and are approved for use with MaxStream 900 MHz Radio Modems (including “Mag Mount”, “Dome”, “Multi-path” and “Panel” antennas).
EMC and safety. Files are located in the ‘documentation’ folder of the MaxStream CD. Important Note MaxStream does not list the entire set of standards that must be met for each country. MaxStream customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market.
Channel Spacing: 400 kHz • ITU Classification: 400KF1D • Output Power: 100 mW EIRP • Notified Body Number: 0891 Contact MaxStream (801) 765-9885 if additional information is required. Europe (2.4 GHz) Approved Antenna List Table A‐03. Antennas approved for use with 24XStream (2.4 GHz) RF Modems in Europe Minimum Separation Manufacturer Part Number Type...
XStream‐PKG‐E™ Ethernet RF Modem – Product Manual v5.x00 [2006.02.24] Contact MaxStream Free and unlimited technical support is included with every MaxStream Radio Modem sold. Please use the following resources for additional support: Documentation: www.maxstream.net/support/downloads.php Technical Support: Phone. (866) 765-9885 toll-free U.S. & Canada (801) 765-9885 Worldwide Live Chat.