  • Page 1 TROM400STD Tankless RO Filtration System with Brushed Nickel Faucet Setup Manual TROM600STD TROM800STD...
  • Page 2: Table Of Contents

    Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Package Contents .
  • Page 3: Safety Information

    Safety Information WARNING: To reduce risk of injury and property damage, you must read this entire guide before assembling, installing, and operating this filtration system . • This RO water filtration system is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety .
  • Page 4: Package Contents

    Package Contents Part Description Part Description Filtration unit Long white drain-water PE tube RO filter Feedwater valve PAC filter Locking clip (x8) Filtration faucet and parts Drain saddle Blue inlet-water PE tube Feedwater valve adapter Yellow purified-water PE tube...
  • Page 5: Product Features

    Product Features Part Description Part Description RO drain with preinstalled tube RO filter compartment and flow restrictor PAC filter compartment Power cord Indicator panel Raw water inlet Purified water outlet Interface Features No . Description PAC filter indicator RO filter indicator Power indicator RO filter reset button PAC filter reset button...
  • Page 6: Operational Specifications

    Operational Specifications Model No . TROM400STD TROM600STD TROM800STD Rated Voltage / Frequency 110–120 V~50/60 Hz 110–120 V~50/60 Hz 110–120 V~50/60 Hz Rated Current Power Consumption 60 W 85 W 85 W Feedwater Water Pressure 14 – 100 psi / 0.1 – 0.69 MPa 14 –...
  • Page 7: How To Use Quick-Connect Fittings

    How to Use Quick-Connect Fittings The inlet, outlets, and connections of this water filtration system use quick-connect fittings to ensure an easy installation . To connect a PE tube to the fitting, follow these steps: Insert the PE tube into the quick-connect fitting . There is a mark on the PE tube to ensure you fully insert the tube into the fitting .
  • Page 8: Connect To The Cold Water Supply

    Connect to the Cold Water Supply CAUTION: DO NOT CONNECT THIS WATER LINE TO A HOT WATER SUPPLY LINE . The water supply to the unit MUST be from the COLD WATER LINE . Using HOT WATER will severely damage your filters . NOTE: We recommend using plumber's tape on all threaded connections to ensure a...
  • Page 9: Install The Faucet

    Install the Faucet CAUTION: Risk of damage . Some kitchen countertop materials, including granite, porcelain, steel, and plastic resin require specialized tools and can be irreparably damaged if unsuitable tools are used . Installing the faucet requires a 1-inch diameter hole in the countertop or sink .
  • Page 10: Connect The Ro Wastewater Tube

    Connect the RO Wastewater Tube The drain saddle is designed to fit around a standard 1 .5 in . OD (outer diameter) drain pipe . Always install the drain saddle before the P-trap and on a straight vertical or horizontal section of the pipe . If installing on the horizontal section, install so that PE tube is located on the top of the pipe .
  • Page 11: Connect Tubes To Filtration Unit

    Connect Tubes to Filtration Unit IMPORTANT: The filtration system has been fitted with protective plugs to ensure system ports are not damaged during shipping . Plugs MUST BE removed before connecting tubing . To remove Outlet Drain plugs, press down release collar, then pull plug out .
  • Page 12: Operation

    Operation The filtration system includes an accessibly designed faucet with a quarter-turn handle . Follow steps below to operate: To dispense water, rotate handle forward 90 degrees . To close faucet, rotate handle back to an upright position . Indicator Lights and Buttons The filtration unit has been designed with a simplified touch interface for easy use .
  • Page 13: Replace The Filters

    Replace the Filters (Fig-16) When one or both of your filter indicators begin to flash, the filter(s) need to be replaced . To change filter: Close the valve on the feedwater adapter . Open the filtration faucet and drain water to release pressure .
  • Page 14: Troubleshooting

    Troubleshooting Problem Probable cause Solution • The feedwater valve is not fully open . • Fully open feedwater valve . The water output • One or both filters are blocked volume has dropped . • Replace one or both filters . or have reached the end of their lifespans .
  • Page 15: Warranty

    Warranty Brio (“Vendor”) warrants to the original purchaser of the Brio Water Filtration System (the “Product”), and to no other person, that if the Product is assembled and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in the Product shall be free from defects in material and workmanship .