Safety Information WARNING: To reduce risk of injury and property damage, you must read this entire manual before assembling, installing, and operating the filtration system. • Installation needs to comply with state and local laws and regulations. • If the power cable is damaged, do not use. Contact customer service for a replacement. •...
Product Features Part Description Part Description PCB filter compartment Filtered water connection RO filter compartment Waste water connection Filter indicator Filtered water lever Inlet water connection Faucet O-ring Indicator Panel Description Item Description Filter indicator lights – When blinking, indicates it is time to change filters (RO or PCB).
Specifications Model No. TROE600PRISM 5.4 x 15.4 x 16.9 in. Product Dimensions (WxHxD) (13.8 x 39.0 x 43.0 cm) Daily Production Rate 600 GPD Purified Flow Rate 1.5 LPM Feed Water Requirement Municipal tap water Feed Water Pressure 15–100 psi Feed Water Temperature 39–100 °F (4–38 °C)
Installation 1. Installation Overview 2. Connect to the Cold Water Supply CAUTION: DO NOT CONNECT THIS WATER LINE TO A HOT WATER SUPPLY LINE. The water supply to the unit MUST be from the COLD WATER LINE. Using HOT WATER will severely damage your filters. Turn off and then disconnect the current cold water supply line.
Insert the shut-off valve tube (J) straight into the quick connector piece of the feed water adapter (D). Tighten the nut on the feed water adapter (D). Gently tug on the shut-of valve tube (J) to ensure a secure connection with the feed water adapter (D).
Page 9
To install the Reverse Osmosis (RO) drain saddle: Determine the location for your drain saddle (H) and then make a mark on the drain pipe for the opening (12). Use your drill and a 1/4 in. drill bit to create a hole at the mark, ensuring you only drill through one side of the drain pipe.
4. Install the Faucet Ensure that you have a mounting hole in your sink or countertop for this faucet. If you do not, create a mounting hole no less than 1.0–1.2 in. (2.54–3.0 cm). Remove the washer (13) and lock nut (14) from the faucet (B). Ensure that you leave the O-ring (8) on the faucet. Attach the 1/4 in.
5. Complete the Installation Connect the shut-off valve tube (J) to the inlet water connection (4). Connect the filtered water tube (K) to the filtered water connection (5). Connect the RO waste water tube (I) to the waste water connection (6). Ensure all connections are secure before proceeding. Operation Start Up the Filtration System Ensure all water connections are completed as described in the Installation section.
Care and Maintenance • Keep this device in a cool, dry place away from direct sunshine. • Use a clean, soft cloth to remove dust build-up. Do not use soap, detergent, or harsh abrasives. • If the filtration system is not going to be used for an extended period of time, close the shut-off valve on tube (J) and unplug the unit from the outlet.
Flushing the Filters Always flush new filters before using. Do not drink the water while flushing. Turn on the faucet and allow water to run for 10 minutes. Turn off the faucet and wait 30 minutes. Turn on the faucet and allow water to run for another 10 minutes. Troubleshooting Problem Probable Cause...
Page 14
Problem Probable Cause Solution The filtration system leaks A component in the filtration system Immediately shut off the main water water. has failed. supply and unplug the unit from power source. Contact customer service for assistance. There is no water output There is an air jam.
Warranty Brio (“Vendor”) warrants to the original purchaser of the Brio Water Filtration System (the “Product”), and to no other person, that if the Product is assembled and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in the Product shall be free from defects in material and workmanship.
Need help?
Do you have a question about the TROE600PRISM and is the answer not in the manual?
Questions and answers