  • Page 1 Manual A 75...
  • Page 2: Personal Protective Equipment

    INTRODUCTION DESCRIPTION Drying room dehumidifier A 75 is designed for drying laundry in communal drying rooms, e.g. in rented accommodation. The dehumidifier can be fitted with a drying pipe system for laundry. The A 75 is a condensation dehumidifier, and is based on the principle that air moisture condenses on cold surfaces.
  • Page 3: Technical Data

    APPLICATION AREA The A 75 dehumidifier is designed for drying laundry in communal drying rooms, e.g. in rented accommodation. The dehumidifier can also be used for other types of drying and climate control in other premises. The dehumidifier is intended for use in heated rooms. + 15–35ºC.
  • Page 4 Timer, mechanical wind-up (accessory) A mechanical timer can be fitted as an accessory to the drying room dehumidifier. Fit the timer in a suitable place (e.g. inside the door) in the drying room, and connect as follows: • Use a cable with 1.5 mm min.
  • Page 5 Start Mechanical wind-up timer. Turn the timer’s knob to the desired running time. NOTE! Never turn the knob backwards without first turning it fully clockwise. Timer The drying room dehumidifier can be fitted with one of the following timers: • Mechanical wind-up timer.
  • Page 6: Maintenance

    SERVICE MAINTENANCE WARNING! Before performing any maintenance work on the drying room dehumidifier, the machine must be disconnected from the electrical supply. This is done by unplugging the connector from the power socket. All maintenance on the electrical system must be performed by qualified electricians. All maintenance on the cooling system must be performed by qualified cooling technicians.
  • Page 7: Warranty

    TRANSPORTATION The dehumidifier must always be transported upright. If it has been lying down, it must be left upright for at least 30 minutes before being started. If it has been transported in or subjected to cold, it should be left standing in a warm room until it reaches room temperature.
  • Page 8 ..............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 9 ..............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................