TriangleTube PARKIT522 Inspection And Installation Instructions

Prestige solo pt and pa, prestige excellence pte and pea condensate trap lock ring

Advertisement

Quick Links

https://triangletube.com/professional-
resources/video-library/
Prestige Solo PT and PA models
Prestige Excellence PTE and PEA models
Condensate Trap Lock Ring - Inspection and Installation
Installation shall be performed by a qualified installer, service agency, or the gas supplier.
CONTENTS
1 - Definitions ......................................................................... 1
2 - Applicability ...................................................................... 1
3 - Purpose ............................................................................. 1
4 - Kit Reference .................................................................... 1
1 - Definitions
The following terms are used throughout this manual to
bring attention to the presence of potential hazards or to
important information concerning the product.
Indicates the presence of a hazardous situation
which, if ignored, will result in substantial
property damage, serious injury, or death.
Indicates a potentially hazardous situation
which, if ignored, can result in substantial
property damage, serious injury, or death.
Indicates special instructions on installation,
operation or maintenance, which are important
to the equipment but not related to personal
This symbol indicates that you need to make
a picture (with your phone or other) for later
reporting.
Pub. Date:02/26/2025
• DANGER
• WARNING
NOTICE
injury hazards.
These instructions shall be kept with the appliance literature for future reference.
• WARNING
5 - Condensate Trap Inspection and Installation ............ 2
5.1
Required tools and material.............................................................2
5.2
Removal and Cleaning Procedure ................................................2
5.3
Inspection Procedure .........................................................................2
5.4
Installation procedure ........................................................................2
5.5
Record and Report ..............................................................................4
This symbol indicates that an instructional
"HOW TO" video is available from Triangle
Tube's website. A direct link to the library is
available at the top left corner of the front cover.
2 - Applicability
Prestige Solo PT 60-110-175-250-399
Prestige Excellence PTE 110.
Prestige Solo PA 80-110-155-175-250-299-399
Prestige Excellence PEA 110.
3 - Purpose
This procedure explains how to check the presence of
the condensate drain lock ring and the installation of a
new one with a specific tool.
The installation of a lock ring with a specific tool will
ensure that the condensate drain located below the
boiler is securely attached to the condensate pan
connection tube.
4 - Kit Reference
For all models, use kit : PARKIT522
The kit is comprised of:
♦ A new lock ring
♦ An installation tool
♦ Installation instructions
A1011122 - 664A0750 • A
Triangle Tube
1240 Forest Parkway, Suite 100,
West Deptford NJ 08066
Tel: (856) 228 8881 - Fax: (856) 228 3584
E-mail:
techsupport@triangletube.com
PARKIT522
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PARKIT522 and is the answer not in the manual?

Questions and answers

Summary of Contents for TriangleTube PARKIT522

  • Page 1 NOTICE 4 - Kit Reference Indicates special instructions on installation, For all models, use kit : PARKIT522 operation or maintenance, which are important to the equipment but not related to personal The kit is comprised of: injury hazards.
  • Page 2 CONDENSATE TRAP LOCK RING - INSPECTION AND INSTALLATION INSTRUCTIONS 5.3 Inspection Procedure 5 - Condensate Trap Inspection Installation 1. Remove both seals located under the retaining nut 5.1 Required tools and material NOTICE ♦ Fresh water If the metal lock ring (2) was (correctly) installed, ♦...
  • Page 3 CONDENSATE TRAP LOCK RING - INSPECTION AND INSTALLATION INSTRUCTIONS 4. Insert the condensate drain retaining nut (1) onto the condensate pan tube, then screw the lock ring (2) on the newly created thread. 5. Finish pushing the lock ring (2) to its final position by screwing the tool fully, then unscrewing it.
  • Page 4 5.5.3 Reporting 1. Connect to the portal (https://r2rportal.triangletube.com) 2. Login to your account. 3. Open the Dashboard menu (located at the top of the screen) and select the current job.