Download Print this page

TriangleTube PARKIT64 Conversion Instructions

Prestige solo 155 - 175 - 250 natural gas to propane conversion

Advertisement

Quick Links

Prestige Solo 155 - 175 - 250
Natural Gas to Propane Conversion Instructions
These instructions shall be kept with the appliance literature for future reference.
Do not use the appliance with propane gas unless these Conversion Instructions have been
This conversion kit shall be installed by a qualified installer, service agency, or the gas
supplier in accordance with the manufacturer's instructions and all applicable codes and
If the information in these instructions is not followed exactly, a fire, an explosion, or production
of carbon monoxide can result causing property damage, personal injury, or loss of life.
The qualified installer, service agency, or the gas supplier is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specified in this manufacturer's instructions supplied with the kit.
Whenever possible, conversion should be carried out before installing and connecting the boiler.
DEFINITIONS
The following terms are used throughout this manual to
bring attention to the presence of potential hazards or to
important information concerning the product.
DANGER
Indicates the presence of a hazardous situation
which, if ignored, will result in substantial property
damage, serious injury, or death.
April 2024
WARNING
fully implemented.
requirements of the authority having jurisdiction.
NOTICE
Triangle Tube
1240 Forest Parkway, Suite 100, West Deptford NJ 08066
Tel: (856) 228 8881 - Fax: (856) 228 3584 E-mail: info@triangletube.com
A1010456 - 660Y4100_EN • B
WARNING
Indicates a potentially hazardous situation which,
if ignored, can result in substantial property
damage, serious injury, or death.
NOTICE
Indicates special instructions on installation,
operation or maintenance, which are important to
the equipment but not related to personal injury
hazards.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PARKIT64 and is the answer not in the manual?

Questions and answers

Summary of Contents for TriangleTube PARKIT64

  • Page 1 Triangle Tube 1240 Forest Parkway, Suite 100, West Deptford NJ 08066 Tel: (856) 228 8881 - Fax: (856) 228 3584 E-mail: info@triangletube.com A1010456 - 660Y4100_EN • B April 2024...
  • Page 2 PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS A. Installer’s conversion data label To be filled in by the installer with relevant information and affixed close to the rating plate Conversion label for gas control valve (EN / FR) To be affixed on top of the gas control valve to indicate that conversion has...
  • Page 3: Kit Contents

    Upon completion of the conversion from Natural Gas Kit Part Number: (NG) to Propane gas (LP): Prestige Solo 155 : PARKIT64 • Affix the new propane gas rating plate (C) included in the kit adjacent to the existing Prestige Solo 175 : PARKIT65 rating label.
  • Page 4 PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS Fig. 3 - Boiler Components 7. Remove the air inlet elbow from the Venturi (1) using a WARNING twist and pull motion. Disconnect the gas supply piping inside the Prestige enclo- A new gasket, provided in the kit, shall be installed sure at the nut (2) located on the bottom of the gas control between the Venturi and the gas control valve...
  • Page 5: Starting Up The Boiler

    PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS 1.4. Starting Up the Boiler. 16. Place the conversion label (B) on the gas control valve WARNING (refer to Fig. 2 on page 2. for the correct location). •...
  • Page 6 PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS 7. Turn the external manual gas valve handle counter clock- 4. Confirm the code by pressing OK, then follow the in- wise to “OPEN” gas supply (valve handle shall be structions displayed on the screen.
  • Page 7 PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS 1.5. Combustion Test and Adjustments If the combustion levels during high fire are outside the rec- ommended combustion settings adjust the Throttle screw (1) using a flat-blade screwdriver, as follows: NOTICE •...
  • Page 8 PRESTIGE SOLO 155 - 175 - 250 - NATURAL GAS TO PROPANE CONVERSION INSTRUCTIONS 1.7. Follow-on tasks 7. If the combustion levels (O 2 & CO 2 ) during low fire are outside the recommended combustion settings in • Fill in the Installer’ s conversion data label (A) with the required Table contact Triangle Tube Technical Support Depart- conversion information and with combustion values.

This manual is also suitable for:

Parkit65Parkit66