Tub-Shower System
Installation Brief
Model Number
S-5102 Tub-Shower System
Decorative Finish Code
append to part numbers if applicable
-STN Satin Nickel
-- Chrome (standard)
Rough-in Installation
Control valve, piping & fittings
Reference rough-in dimension illustration
on page 2 as required.
1)
Determine wall thickness
■ Determine type of wall and wall
thickness where valve will be mounted.
■ Consider whether to use mounting plate
by reviewing figure 2 below.
■ Skip ahead to
if mounting
Step 3
plate will not be used.
2)
Attach mounting plate to valve
Seat mounting plate against valve
assembly as illustrated in figure 1.
Walls for using T-177 mounting plate
Fiberglass or acrylic walls (required)
Plaster or other type walls (optional)
1/16" (2 mm) min 1/2" (13 mm) max
Protective shield
When mounting plate is used,
then shield is optional for
protecting end of valve during
installation.
"snap on-off"
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer,
birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Winslet
Tools & Materials
3)
Attach protective shield
■ Reference figure 2 to determine
whether shield is required.
■ Attach plastic protective shield by
snap fitting over end of valve spindle.
nished
p/n T-177
p/n T-176
wall cutout hole size
3-1/2" (95 mm) min
4" (101 mm) max
®
S-5102
Plumbers
Putty
1
2
3
4
Figure 1 Mounting plate
Dry wall, plaster or other type wall
Ensure valve's
mounting plate
wall
is ush against
inner wall
Finished wall must be
ush with back side of
protective shield surface
Protective shield
"snap on-off"
(required when
mounting plate
is not used)
wall cutout hole size
3-1/2" (89 mm) min
Figure 2 Mounting valve
Need Help?
Contact Symmons customer service
Phone: (800) 796-6667
gethelp@symmons.com
Mon - Fri 7:30 am - 6:00 pm EST
Please check Symmons website
for technical help, the latest product
information and warranty policy.
www.symmons.com/service
4)
Install piping, fittings and
control valve
Piping and fittings not supplied
■ Control Valve
Install valve through cutout hole in
wall as specified in figure 2 below and
dimension illustration on page 2.
■ Showerhead (S on valve)
Pipe from outlet port on valve marked
to showerhead mounting arm location.
■ Hot & Cold Supply (H & C)
Pipe hot water supply to valve input
marked
H
valve input marked
■ Tub Spout (T on valve)
Pipe from outlet port on valve marked
T
to tub spout.
1/2" (13 mm) or greater
nished wall
2-3/8" ± 1/2"
(60 mm ± 13 mm)
pipe centerline
to nished wall
4" (101 mm) max
S
and cold water supply to
.
C