About this manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. Documentation mentioned in the “Installation” user manual that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at: https://www.doc.hirschmann.com...
Important information Read these instructions carefully, and familiarize yourself with the device before trying to install, operate, or maintain it. The following notes may appear throughout this documentation or on the device. These notes warn of potential hazards or call attention to information that clarifies or simplifies a procedure. Installation GRS2000/GRS2100 Release 02 - 04/2025...
Warning symbols This is a general warning symbol. This symbol alerts you to potential personal injury hazards. Observe all safety notes that follow this symbol to avoid possible injury or death. If this symbol is displayed in addition to a safety instruction of the type “Danger” or “Warning”, it means that there is a danger of electric shock and failure to observe the instructions will inevitably result in in...
Page 6
NOTICE NOTICE provides information about procedures that do not involve the risk of injury. Installation GRS2000/GRS2100 Release 02 - 04/2025...
Contents A bout this manual....................3 I mportant information................... 4 W arning symbols....................5 1. S afety instructions..................11 1.3. Q ualification requirements for personnel..........12 1.4. I ntended use..................12 1.5. I nstallation site requirements............... 13 1.6.
Page 8
3.10.3. D escription supply voltage 100 V AC ... 240 V AC (50 Hz ... 60 Hz), or 60 V DC ... 250 V DC............31 3.11. M anagement Interfaces..............33 3.11.1. M anagement interface MGMT (external management)... 33 3.12. E thernet ports..................35 3.12.2. T wisted pair port 10/100/1000 Mbit/s........35 3.12.3.
Page 9
6.2. M onitoring the ambient humidity............61 7. M aintenance and service................63 8. D isassembly....................64 8.1. R emoving an SFP transceiver (optional)..........64 8.2. R emoving the device................64 8.3. R emoving the ACA41 microSD card (optional)........66 9.
Page 10
9.12.4. G igabit Ethernet SFP transceiver..........82 9.12.5. 2 .5 Gigabit Ethernet SFP transceiver........82 9.13. S cope of delivery................83 9.14. O rder numbers...................83 9.15. U nderlying technical standards............84 A. F urther support....................86 Installation GRS2000/GRS2100 Release 02 - 04/2025...
1 - Safety instructions 1. Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS Failure to follow these instructions can result in death, serious injury, or equipment damage. To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices.
1.1 - Qualification requirements 1 - Safety instructions for personnel 1.1. Qualification requirements for personnel Only allow qualified personnel to work on the device. Qualified personnel have the following characteristics: • Qualified personnel are properly trained. Training as well as practical knowledge and experience make up their qualifications.
1.3 - Installation site 1 - Safety instructions requirements 1.3. Installation site requirements • Operate the device only at the specified ambient temperature (temperature of the ambient air at a distance of 5 cm (2 in) from the device) and at the specified relative humidity. •...
1 - Safety instructions 1.5 - Strain relief 1.5. Strain relief Note: I f the strain relief is insufficient, there is a potential risk of torsion, contact problems and creeping interruptions. • Relieve the connection points of cables and lines from mechanical stress.
1 - Safety instructions 1.6 - Electrical connections 1.6.3. General requirements for connecting electrical wires Before connecting the electrical wires, ALWAYS verify that the requirements listed are complied with. The following requirements apply without restriction: • The cables used are permitted for the temperature range of the application case.
1 - Safety instructions 1.6 - Electrical connections 1.6.4.1. DC voltage power supply: • The device is rated for DC voltage. • The conductor cross-section of the power supply cable is at least 1 mm² (16 AWG) on the supply voltage input of the device. •...
1 - Safety instructions 1.7 - LED or laser components 1.7. LED or laser components LED or LASER components according to IEC 60825-1 (2014): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT 1.8. Recycling note The symbol of a crossed-out wheeled bin shown on the device indicates that the device MUST NOT be disposed of with household waste at the end of its service life.
2 - Approvals 2. Approvals 2.1. CE marking The labeled devices comply with the regulations contained in the following European directive(s): • 2011/65/EU and 2015/863/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
2.2. FCC note Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information GRS2000/GRS2100 U.S. Contact Information Belden Inc. – St. Louis 1 N Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with Part 15 of the FCC Rules. Operation is subject...
3 - Description 3. Description The Hirschmann network components help you ensure continuous communication across all levels of the company. The device provides you with a range of device variants. The device is designed for the special requirements of industrial automation. The device meets the relevant industry standards, provides very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility.
Page 21
3 - Description • Web browser • SSH • Network management software (for example Industrial HiVision) The Network Management Software Industrial HiVision provides you with options for smooth configuration and monitoring. You find further information on the Internet at the Hirschmann product pages: https://www.hirschmann.com/en/QR/INET-Industrial-HiVision •...
3.1 - Device name and product 3 - Description code 3.1. Device name and product code The device name corresponds to the product code. The product code is made up of characteristics with defined positions. The characteristic values stand for specific product properties.
Page 25
3.1 - Device name and product 3 - Description code Table 1. Device name and product code: GRS2000/GRS2100 (continued) Characteristic val Item Characteristic Description F/O connections + SFPs: PG 4 DSC: 100 Mbit/s MM DST: 100 Mbit/s MM DSC: 100 Mbit/s SM DST: 100 Mbit/s SM SFP: 100 Mbit/s MM/LC EEC SFP: 100 Mbit/s SM/LC EEC SFP: 1 Gbit/s SX/LC EEC...
Page 26
3.1 - Device name and product 3 - Description code Table 1. Device name and product code: GRS2000/GRS2100 (continued) Characteristic val Item Characteristic Description Extended: -40 °C … +70 °C (-40 °F … +158 °F) with Conformal Coating (CC) Voltage range PSU 1 60 V DC ... 250 V DC or 100 V AC ... 240 V AC Voltage range PSU 2 60 V DC ...
3 - Description 3.2 - Device views 3.2. Device views 3.2.1. Front view For the available number and types of connections and port groups on your device, check the product code: Device name and product code on page Figure 1. Front view: Example of GRS2000... device variants (power supply characteristic value KK) Table 2.
Page 28
3 - Description 3.2 - Device views Figure 2. Front view: Example of GRS2100... device variants (power supply characteristic value KK) Table 3. Front view: Description of device elements - example of GRS2100... device variants (power supply characteristic value KK) Status LED AutoConfiguration Adapter (ACA) Management interface (MGMT) Status LED Device status (Status)
3 - Description 3.3 - Power supply Table 6. Rear view: Description of device elements - example of GRS2100... device variants (power supply characteristic value KK) (continued) Port group 5 (PG 5): SFP slots/uplink Protective ground screw Oblong hole Mounting bracket Power supply connection 2 (P2) Power supply connection 1 (P1) Status LED Port/Slot status 3.3.
3 - Description 3.3 - Power supply Figure 6. Supply voltage: Example for the supply voltage location on GRS21xx... device variants (rear side of the device) The supply voltage can be connected redundantly. Both inputs are electrically isolated from each other. When 2 power supply units are used, the load is distributed.
3 - Description 3.3 - Power supply Figure 7. Connecting supply voltage 100 V AC ... 240 V AC (50 Hz ... 60 Hz), or 60 V DC ... 250 V DC: 3-pin terminal blocks with screw lock Table 7. Description supply voltage 100 V AC ... 240 V AC (50 Hz ... 60 Hz), or 60 V DC ... 250 V DC: Specifications Type of supply Pin assign...
3 - Description 3.5 - Ethernet ports The LED display element next to the ACA41 microSD card interface informs you about the status of the interface. 3.5. Ethernet ports You can connect end devices and other segments to the device ports using twisted pair (TP) cables or optical fibers (F/O).
3 - Description 3.5 - Ethernet ports • 100 Mbit/s full duplex mode when using a Fast Ethernet SFP transceiver • 1000 Mbit/s full duplex mode when using a Gigabit Ethernet SFP transceiver Note: T he F/O connection speed 100/1000 Mbit/s is NOT available on PG5. ...
Page 38
3 - Description 3.5 - Ethernet ports Note: T he port/slot speed available to you on each port group and the number of ports depends on the data rate characteristic value of your device variant and the individual types of the chosen port group(s). S ee item 6 in the product code: Device name and product code on page 22 ...
3 - Description 3.6 - Display elements 3.6. Display elements After the supply voltage is set up, the software starts and initializes the device. Afterwards, the device performs a self-test. During this process, various LEDs light up. 3.6.1. Device status This LED provides information about conditions which affect the operation of the whole device.
3 - Description 3.6 - Display elements Table 9. Power LED: Color, activity and meaning Color Activity Meaning none none Supply voltage is too low or not available yellow lights up Device variants with redundant power supply Supply voltage 1 or 2 is on yellow flashes 4 ×...
Page 41
3 - Description 3.6 - Display elements Figure 14. Port status: Example for LED display element location on GRS2000... device variants (front side of the device) Figure 15. Port status: Example for LED display element location on GRS2100... device variants (front side of the device) Note: ...
Page 42
3 - Description 3.6 - Display elements Table 12. Port status LED: Color, activity and meaning (continued) Color Activity Meaning green lights up Device detects a valid link green flashes 1 × a period Port is switched to stand-by Installation GRS2000/GRS2100 Release 02 - 04/2025...
4 - Installation 4. Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. To install and configure the device, perform the following work steps: • Checking the package contents on page 43 •...
Page 44
4.2 - Selecting the installation 4 - Installation location The device can be installed on a flat surface, vertically on a flat surface, or in a 19" standard switch c abinet. When selecting the installation location, ensure the following requirements are met: •...
4.3 - Installing the ACA41 4 - Installation microSD card (optional) 4.3. Installing the ACA41 microSD card (optional) Figure 16. Installing the ACA41 microSD card (optional): Mounting the microSD card and location on the device (front side of device variants GRS2000...) MGMT P Status Figure 17.
4 - Installation 4.4 - Mounting the device 4.4. Mounting the device WARNING ELECTRIC SHOCK Failure to follow these instructions can result in death, serious injury, or equipment damage. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the device or into the connection terminals for electric conductors.
4 - Installation 4.4 - Mounting the device You have the following option(s) for mounting your device: • Mounting on a flat surface on page 47 • Mounting in a switch cabinet on page 49 4.4.1. Mounting on a flat surface WARNING FIRE HAZARD Failure to follow these instructions can...
Page 48
4 - Installation 4.4 - Mounting the device • You have the required number of mounting brackets necessary for mounting the device on a flat surface (4 ×). In the delivery state, there are 2 pre-mounted mounting brackets on the sides of the device. You obtain additional brackets as accessories: Accessories on page 80 Figure 18.
4 - Installation 4.4 - Mounting the device Note: T he device must NOT be used as a desktop device. 4.4.2. Mounting in a switch cabinet CAUTION OVERHEATING OF THE DEVICE Failure to follow these instructions can result in injury or equipment damage. When installing the device, make sure any ventilation slots remain free.
Page 50
4 - Installation 4.4 - Mounting the device Figure 19. Assembly in a switch cabinet with sliding/ mounting rails 1 - device 2 - sliding/mounting rail 3 - 19" switch cabinet Perform the following work steps: • Assemble the sliding or mounting rails in the 19" switch cabinet as specified by the manufacturer.
4 - Installation 4.5 - Grounding the device Figure 20. Mounting in a switch cabinet: Mounting brackets with oblong holes Note: W hen operating the device in an environment with continuous vibration loads, Hirschmann recommends to additionally fasten the device to the switch cabinet using 2 mounting brackets on the front or rear side of the device. ...
4.6 - Installing an SFP 4 - Installation transceiver (optional) Figure 21. Grounding the device: Ground screw next to power supply connection(s) (exemplary view using device power supply characteristic value KK) The device has a protective ground connection (protective ground screw) next to the power supply connection(s) on the front or rear side of the device, depending on device variant.
4.7 - Connecting the signal 4 - Installation contact • Take the SFP transceiver out of the transport packaging (1). • Remove the protection cap from the SFP transceiver (2). • Push the SFP transceiver with the lock closed into the slot until it latches in (3).
4.8 - Connecting the supply 4 - Installation voltage WARNING ELECTRIC SHOCK Failure to follow these instructions can result in death, serious injury, or equipment damage. Never insert pointed objects (narrow screwdrivers, wires, etc.) into the device or into the connection terminals for electric conductors.
Page 55
4.8 - Connecting the supply 4 - Installation voltage Table 13. Connecting supply voltage 100 V AC ... 240 V AC (50 Hz ... 60 Hz), or 60 V DC ... 250 V DC: Specifications (continued) Type of supply Pin assign voltage that can be Specification of the supply voltage Meaning ment connected 85 V AC ...
4 - Installation 4.9 - Operating the device 4.9. Operating the device WARNING ELECTRIC SHOCK Failure to follow these instructions can result in death, serious injury, or equipment damage. Exclusively connect the supply voltage that corresponds with the type plate of your device. Note: ...
Page 57
4 - Installation 4.10 - Connecting data cables • Keep the length of the data cables as short as possible. • Use optical data cables for the data transmission between buildings. • When using copper cables, provide a sufficient separation between the power supply cables and the data cables.
5 - Basic settings 5. Basic settings Note: 2 or more devices configured with the same IP address can cause unpredictable operation of your network. Perform the following work step: • Install and maintain a process that assigns a unique IP address to every device in the network.
5 - Basic settings 5.1 - Default settings 5.1. Default settings • Ethernet ports: link status is not evaluated (signal contact) • IP address: The device looks for its IP address parameters using DHCP • Management password: Login: user, password: public (read only) Login: admin, password: private (read/write) •...
Page 60
• Log on to the device again with your new password. Note: I f you lost your password, use the System Monitor to reset the password. For further information, see https://hirschmann-support.belden.com/en/kb/ required-password-change-new-procedure-for-first-time-login Installation GRS2000/GRS2100 Release 02 - 04/2025...
6 - Monitoring ambient conditions 6. Monitoring ambient conditions 6.1. Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See: Climatic conditions during operation on page 71 The ambient air temperature is the temperature of the air at a distance of 5 cm (2 in) from the device.
Page 62
6.2 - Monitoring the ambient 6 - Monitoring ambient conditions humidity For more information refer to the software user manuals. You can download these manuals as PDF files from the Internet on the Hirschmann product pages (https://www.doc.hirschmann.com). Installation GRS2000/GRS2100 Release 02 - 04/2025...
You find information and software downloads on the Hirschmann product pages on the Internet (https://www.belden.com). • Depending on the pollution degree of the operating environment, check regularly that the cooling fins and surfaces of the device are not obstructed.
8 - Disassembly 8. Disassembly 8.1. Removing an SFP transceiver (optional) Figure 24. De-installing SFP transceivers: De-installation sequence Perform the following work steps: • Open the locking mechanism of the SFP transceiver (1). • Pull the SFP transceiver out of the slot via the open locking mechanism (2).
Page 65
8 - Disassembly 8.2 - Removing the device Figure 25. Removing the device: Mounting brackets with oblong holes Perform the following work steps: • Disconnect the data cables. • Disable the supply voltage. Note: T he device contains a built-in energy storage. When you disable the supply voltage, the device may thus continue to run for a few seconds before switching off. ...
8.3 - Removing the ACA41 8 - Disassembly microSD card (optional) 8.3. Removing the ACA41 microSD card (optional) Figure 26. Removing the ACA41 microSD card (optional): Removing the microSD card and location on the device (front side of device variants GRS2000...) MGMT P Status Figure 27.
9 - Technical data 9. Technical data 9.1. General data Dimensions See: Dimension drawings on page 69 Weight Depending on device variant 5.7 kg ... 6.5 kg (12.6 lb ... 14.3 lb) Pollution degree Laser protection Class 1 in compliance with IEC 60825-1 Degree of protection IP30 Ground connection Screw type Tightening torque 0.34 Nm (3 lb-in)
9.3 - Power consumption/power 9 - Technical data output Characteristic: slow blow Overload current protection on the Non-replaceable fuse device Peak inrush current <5 A 9.3. Power consumption/power output Table 14. Power consumption/power output Product code Maximum power consumption Maximum power output GRS2..0-.…-00000-...
9.6 - Climatic conditions during 9 - Technical data operation 9.6. Climatic conditions during operation Table 16. Climatic conditions during operation Climatic conditions during operation Ambient air up to 2000 m ASL Operating temperature range Standard: 0 °C … +60 °C (+32 °F … +140 °F) temperature (6562 ft ASL) characteristic value S Operating temperature range...
9.7 - Climatic conditions during 9 - Technical data storage 9.7. Climatic conditions during storage Table 17. Climatic conditions during storage Climatic conditions during storage Ambient temperature -40 °C ... +70 °C (-40 °F ... +158 °F) up to 1 year -40 °C ... +50 °C (-40 °F ... +122 °F) up to 2 years 0 °C ...
Page 73
9 - Technical data 9.8 - Derating Note: A lternatively to a derating, the device can be installed with additional cooling. If a stable airflow of at least 100 LFM on the device can be provided, the derating is void. 9.8.1.1.
9.10 - Electromagnetic 9 - Technical data compatibility (EMC) 9.10. Electromagnetic compatibility (EMC) 9.10.1. EMC interference emission Table 24. EMC interference emission: Standard applications Applicable standard Connection type Specification Radiated emission FCC 47 CFR Part 15 Class A EN 55032 Class A Table 25. EMC interference emission: Substation applications Applicable standard Connection type Specification...
Page 76
9.10 - Electromagnetic 9 - Technical data compatibility (EMC) Table 26. EMC interference immunity: Standard applications (continued) Applicable standard Connection type Voltage EN 61000-4-4 Power supply connection ±2 kV Voltage surges - DC supply connection Voltage surges - power supply connection EN 61000-4-5 line/ground 2 kV Supply voltage HV...
9 - Technical data 9.11 - Network range Table 28. EMC interference immunity: Substation applications (continued) Applicable standard Connection type Voltage IEEE 1613 line/ground ±5 kV EN 61000-4-5 line/line ±1 kV Voltage surges - data line EN 61000-4-5 line/ground ±2 kV Conducted disturbances EN 61000-4-6 150 kHz ...
9 - Technical data 9.11 - Network range 9.11.2. Fast Ethernet SFP transceiver Table 30. F/O port 100BASE-FX (SFP Fiber Optic Fast Ethernet Transceiver) Product Wave System at Example for F/O ca Fiber atten Mode Fiber BLP/Dispersion code length tenuation ble length uation M-FAST-...
FCC, UL 61010-2-201, DNV, Lloyd’s Register, Bureau Veritas, UL 121201 (Hazardous Locations), IEC 61850-3, EN 50121-4, ATEX or IECEx. You find further information on certifications on the Internet at the Hirschmann product pages: https://www.belden.com 24. The temperature range specifications refer to the use in the GRS device. Installation GRS2000/GRS2100...
9 - Technical data 9.12 - Accessories 9.12.2. Gigabit Ethernet SFP transceiver Table 35. Accessories: Gigabit Ethernet SFP transceiver Gigabit Ethernet SFP Certification Order Temperature range transceiver type number The following operating conditions apply to twisted pair transceivers: • Longer RSTP switching times and link loss detection times compared to twisted pair ports provided by the device directly.
9 - Technical data 9.13 - Scope of delivery 9.13. Scope of delivery Table 37. Scope of delivery Amount Article 1 × Device 1 × Safety and general information sheet 1 × Terminal block for the supply voltage or 2 × (depending on (depending on number and type of PSUs) device variant) 1 ×...
You will find out whether your device has other shipping approvals on the Hirschmann website at: https:// in the product information. www.belden.com Table 39. List of technical standards ANSI/ISA 12.12.01 Non-incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations...
Page 85
9.15 - Underlying technical 9 - Technical data standards Table 39. List of technical standards (continued) FCC 47 CFR Part 15 Code of Federal Regulations IEEE 802.1D Media Access Control Bridges IEEE 802.1Q Virtual Bridged Local Area Networks IEEE 802.1w Rapid Reconfiguration IEEE 802.3 Ethernet NEMA TS 2 Traffic Controller Assemblies with NTCIP Requirements (environmental requirements) IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communication Networking Devices in Electric Power Substations...
For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You find the addresses of our partners on the Internet at: https://www.belden.com A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at: https://hirschmann-support.belden.com...