KERN KFF-T Operating And Installation Instructions

Display device
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Betriebs- und Installationsanleitung Anzeigegerät
Operating and Installation Instructions Display device
Instructions d'utilisation et d'installation Appareil d'affichage
KERN KFF-T
Version 1.1
02/2011
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
KFF-T-BA_IA-def-1111

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KFF-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KERN KFF-T

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Betriebs- und Installationsanleitung Anzeigegerät Operating and Installation Instructions Display device Instructions d’utilisation et d’installation Appareil d’affichage KERN KFF-T Version 1.1 02/2011 KFF-T-BA_IA-def-1111...
  • Page 2 Vous trouverez d’autres versions de langue online sous www.kern-sohn.com/manuals Further language versions you will find online under www.kern-sohn.com/manuals A használati utasítás egyéb nyelveken a www.kern-sohn.com/manuals címről tölthető le Trovate altre versioni di lingue online inwww.kern-sohn.com/manuals Ytterligere språkversjoner finner du online under www.kern-sohn.com/manuals Bijkomende taalversies vindt u online op www.kern-sohn.com/manuals...
  • Page 3: Table Of Contents

    KERN KFF-T Version 1.1 02/2011 Betriebs- und Installationsanleitung Anzeigegerät Inhaltsverzeichnis Technische Daten....................4 Geräteübersicht ....................5 Tastaturübersicht......................6 2.1.1 Numerische Eingabe über Navigationstasten ..............7 Anzeigenübersicht ......................7 Grundlegende Hinweise (Allgemeines) ............8 Bestimmungsgemäße Verwendung ................8 Sachwidrige Verwendung.....................8 Gewährleistung......................8 Prüfmittelüberwachung....................9 Grundlegende Sicherheitshinweise..............9 Hinweise in der Betriebsanleitung beachten ..............9...
  • Page 4 Wartung, Instandhaltung ....................28 Entsorgung .........................28 Fehlermeldungen......................28 Datenausgang RS 232C................29 10.1 Technische Daten.......................29 10.2 Drucker Betrieb......................29 10.3 Kontinuierliche Datenausgabe..................29 Kleine Pannenhilfe..................30 Installation Anzeigegerät / Wägebrücke ............ 31 12.1 Technische Daten.......................31 12.2 Aufbau des Wägesystems..................31 12.3 Plattform anschließen....................32 12.4 Anzeigegerät konfigurieren..................33 KFF-T-BA_IA-d-1111...
  • Page 5: Technische Daten

    1 Technische Daten KERN KFF-T Anzeige 6 - stellig Auflösung 30.000 Wägebereiche Ziffernschritte 1,2,5,…10, n Wägeeinheiten g, kg, lb, oz, tJ, hJ Display LCD 22 mm Ziffern, hinterleuchtet 80-100 Ω. Max. 4 Stück à 350 Ω; DMS-Wägezellen Empfindlichkeit 2-3 mV/V Eingangspannung 220 V –...
  • Page 6: Geräteübersicht

    2 Geräteübersicht Vorderansicht Anzeigegerät (Empfänger): 1. Antenne 2. Akkuzustand 3. Gewichtsanzeige 4. Tastenfeld Rückansicht Anzeigegerät (Empfänger): 5. RS-232 6. Anschluss Netzadapter 7. Tischfuß Anschlussbox (Sender) 8. Antenne 9. Ein-/Ausschalter 10. Anschluss Netzadapter 11. Eingang Anschluss Lastzellenkabel KFF-T-BA_IA-d-1111...
  • Page 7: Tastaturübersicht

    • Bei numerischer Eingabe blinkende Ziffer erhöhen Navigationstaste • Im Menü vorwärts blättern • Wägewert in Summenspeicher addieren • Anzeige Gesamtsumme • Wägedaten über Schnittstelle übermitteln • Löschen • Umschalten Bruttogewicht Nettogewicht • Ziffernanwahl nach rechts Navigationstaste • Wägeeinheit umschalten • Zurück ins Menü/Wägemodus KFF-T-BA_IA-d-1111...
  • Page 8: Numerische Eingabe Über Navigationstasten

    Blinkende Ziffer erhöhen Ziffernanwahl nach links Pfeiltaste  Löschen Pfeiltaste Ziffernanwahl nach rechts Pfeiltaste Eingabe abschließen 2.2 Anzeigenübersicht Anzeige Bedeutung Ladezustand des Akkus STABLE Stabilitätsanzeige ZERO Nullanzeige GROSS Bruttogewicht Nettogewicht AUTO Automatisches Summieren aktiv Summieren Indikatoren für Wägen mit Toleranzbereich KFF-T-BA_IA-d-1111...
  • Page 9: Grundlegende Hinweise (Allgemeines)

    Das Anzeigegerät darf nicht konstruktiv verändert werden. Dies kann zu falschen Wägeergebnissen, sicherheitstechnischen Mängeln sowie der Zerstörung des Anzei- gegerätes führen. Das Anzeigegerät darf nur gemäß den beschriebenen Vorgaben eingesetzt werden. Abweichende Einsatzbereiche/Anwendungsgebiete sind von KERN schriftlich frei- zugeben. 3.3 Gewährleistung Gewährleistung erlischt bei •...
  • Page 10: Prüfmittelüberwachung

    4.1 Hinweise in der Betriebsanleitung beachten Betriebsanleitung vor der Aufstellung und Inbetriebnahme sorgfältig durchlesen, selbst dann, wenn Sie bereits über Erfahrungen mit KERN- Waagen verfügen. 4.2 Ausbildung des Personals Das Gerät darf nur von geschulten Mitarbeitern bedient und gepflegt werden.
  • Page 11: Auspacken Und Aufstellen

    Die Sendefrequenz von Anzeigegerät und Anschlussbox ist werkseitig einge- stellt. 6.3 Lieferumfang/Serienmäßiges Zubehör: • Anzeigegerät, s. Kap. 2 • Anschlussbox, s. Kap. 2 • 2 Netzgeräte • Kabelverschraubung • Betriebsanleitung KFF-T-BA_IA-d-1111...
  • Page 12: Netzanschluss

    6.4 Netzanschluss Die Stromversorgung erfolgt über das externe Netzgerät. Der aufgedruckte Span- nungswert muss mit der örtlichen Spannung übereinstimmen. Verwenden Sie nur KERN- Originalnetzgeräte. Die Verwendung anderer Fabrikate bedarf der Zustimmung von KERN. 6.5 Akkubetrieb Der Akku sollte vor der ersten Benutzung mindestens 12 Stunden über das Netzteil geladen werden.
  • Page 13 Justiergewicht vorsichtig in die Mitte der Wägeplatte stellen. Stabilitätsanzeige abwarten, dann drücken. Nach erfolgter Justierung führt die Waage einen Selbsttest durch. Justiergewicht während des Selbsttests abnehmen, das Gerät kehrt automatisch in den Wägemodus zurück. Bei einem Justierfehler oder falschem Justiergewicht wird eine Fehlermeldung angezeigt, Justiervorgang wiederholen. KFF-T-BA_IA-d-1111...
  • Page 14: Linearisierung

    Wägeplatte stellen. Stabilitätsanzeige abwarten, dann drücken. Nach erfolgter Justierung führt die Waage einen Selbsttest durch. Justiergewicht während des Selbsttests abnehmen, das Gerät kehrt automatisch in den Wägemodus zurück. Bei einem Justierfehler oder falschem Justiergewicht wird eine Fehlermeldung angezeigt, Justiervorgang wiederholen. KFF-T-BA_IA-d-1111...
  • Page 15: Betrieb

    Überlastungen des Gerätes über die angegebene Höchstlast (Max), abzüglich einer eventuell bereits vorhandenen Taralast, unbedingt vermeiden. Das Ge- rät könnte hierdurch beschädigt werden. Die Überschreitung der Höchstlast wird mit der Anzeige „ol“ und einem Signalton angezeigt. Wägesystem entlasten bzw. Vorlast verringern. KFF-T-BA_IA-d-1111...
  • Page 16: Wägen Mit Tara

    Der Tariervorgang kann beliebige Male wiederholt werden, beispielsweise beim Einwiegen von mehreren Komponenten zu einer Mischung (Zuwiegen). Die Gren- ze ist dann erreicht, wenn der gesamte Wägebereich ausgelastet ist. kann zwischen Bruttogewicht und Nettogewicht umgeschaltet werden. Zum Löschen des Tarawertes Wägeplatte entlasten und drücken. KFF-T-BA_IA-d-1111...
  • Page 17: Wägeeinheiten

    Wägeeinheit aktivieren [off] / deaktivieren [on]. bestätigen. Vorgang für jede gewünschte Wägeeinheit wiederholen. wiederholt drücken, das Gerät kehrt zurück in den Wägemodus 2. Wägeeinheiten umschalten Im Wägemodus kann mit in die zuvor aktivierten Wägeeinheiten umges chal- tet werden. KFF-T-BA_IA-d-1111...
  • Page 18: Wägen Mit Toleranzbereich

    Einstellung wird angezeigt. Mit den Navigationstasten (s. Kap. 2.1.1) unteren Grenzwert z. B. 1.000 kg eingeben, die jeweils aktive Stelle blinkt. Eingabe mit bestätigen. wählen SET HI drücken, die aktuelle Einstellung des oberen Grenzwer- tes wird angezeigt. KFF-T-BA_IA-d-1111...
  • Page 19 Wägegut auflegen, die Toleranzkontrolle wird gestartet. Wägegut unter Wägegut innerhalb Wägegut über vorgegebener Toleranz vorgegebener Toleranz vorgegebener Toleranz • Die Toleranzkontrolle ist nicht aktiv, wenn das Gewicht unter 20d liegt. • Zum Löschen der Grenzwerte Wert „00.000 kg“ eingeben. KFF-T-BA_IA-d-1111...
  • Page 20: Manuelles Summieren

    Dieser Vorgang kann so oft wiederholt werden bis die Kapazität des Wä- gestystems erschöpft ist. Anzeige der gespeicherten Wägedaten: Bei Nullanzeige drücken, die Anzahl Wägungen gefolgt vom Gesamtgewicht werden 2 sec. lang angezeigt und bei Anschluss eines optionalen Druckers aus- gegeben. KFF-T-BA_IA-d-1111...
  • Page 21 Die Daten im Summenspeicher werden gelöscht. Ausdruckbeispiel (Menüeinstellung „F5 Prt“ „pr 0 / Lab 0“): 1 Erste Wägung 2 Zweite Wägung 3 Dritte Wägung 4 Anzahl Wägungen/Gesamtsumme Weitere Ausdruckbeispiele abhängig von der Einstellung im Menü „F5 Prt“ „pr/Lab“, s. Kap. 8.2 „Tab. 1“. KFF-T-BA_IA-d-1111...
  • Page 22: Automatisches Summieren

    Dieser Vorgang kann so oft wiederholt werden bis der Kapazität des Wägesystem erschöpft ist. • Nach Ertönen des Signaltons kann Wägegut entfernt oder hinzugefügt wer- den. • Wägedaten anzeigen und löschen, sowie Ausdruckbeispiel siehe Kap. 7.8. KFF-T-BA_IA-d-1111...
  • Page 23: Tierwägen

    Hat sich das Wägegut etwas beruhigt, ertönt ein Signalton. Der gebildete Mittel- wert wird angezeigt. Während der Mittelwertbildung kann Wägegut hinzugefügt oder abgenomen wer- den, da der Wägewert ständig aktualisiert wird. Zur Deaktivierung der Tierwägefunktion / zurück in den Wägemodus Menüeinstellung , s. Kap. 12.4 wählen. KFF-T-BA_IA-d-1111...
  • Page 24: Menü

    Einstellung wird angezeigt. Einstellungen ändern Mit den Navigationstasten, s. Kap. 2.1.1 kann in die ver- fügbaren Einstellungen umgeschaltet werden. Einstellung bestäti- Entweder mit speichern oder mit verwerfen. gen/Menü verlassen Zurück in den Zum Verlassen des Menüs wiederholt drücken. Wägemodus KFF-T-BA_IA-d-1111...
  • Page 25: Übersicht

    Kap. 7.7 Liegt das Wägegut innerhalb des Toleranzbe- bp 2 reiches, wird [ok] angezeigt und das akusti- sches Signal ertönt. Liegt das Wägegut außerhalb des Toleranzbe- bp 3 reiches, wird [ok] angezeigt und das akusti- sches Signal ertönt. KFF-T-BA_IA-d-1111...
  • Page 26 Entlasten der Wage in den Summen- speicher addiert und ausgegeben. 2. Baudrate Nach Bestätigung des RS-232-Modus wird die aktuell eingestellte Baudrate (b xxxx) angezeigt. Mit gewünschten Baudrate auswählen und mit bestätigen. Baudrate wählbar 600, 1200, 2400, 4800, 9600 KFF-T-BA_IA-d-1111...
  • Page 27 Nicht dokumentiert Cont 3 Nicht dokumentiert 4. Druckertyp Nach Bestätigung des Datenausgabeformats wird der aktuell ein- gestellte Druckertyp angezeigt. gewünschten Druckertyp anwählen und mit bestätigen. KERN P Standarddruckereinstellung (ty-tp) LP50 Nicht dokumentiert Ty 711 Nicht dokumentiert s. Kap. 12.4 * = Werkseinstellung...
  • Page 28 0.888 kg 0.666 kg 0.222 kg 0.222 kg 0.222 kg TOTAL: 1.666 kg 0.666 kg GW:: 0.888 kg 0.888 kg TOTAL: 1.666 kg GS / GW Bruttogewicht Nettogewicht Taragewicht Anzahl Wägungen TOTAL Summe aller Einzelwägungen DATE Datum TIME Uhrzeit KFF-T-BA_IA-d-1111...
  • Page 29: Wartung, Instandhaltung, Entsorgung

    Vor der Reinigung das Gerät bitte von der Betriebsspannung trennen. Keine aggressiven Reinigungsmittel (Lösungsmittel o.Ä.) benutzen. 9.2 Wartung, Instandhaltung Das Gerät darf nur von geschulten und von KERN autorisierten Servicetechnikern geöffnet werden. Vor dem Öffnen vom Netz trennen. 9.3 Entsorgung Die Entsorgung von Verpackung und Gerät ist vom Betreiber nach gültigem nationa-...
  • Page 30: Datenausgang Rs 232C

    Für die Kommunikation zwischen Wägesystem und Drucker müssen folgende Bedin- gungen erfüllt sein: Anzeigegerät mit einem geeigneten Kabel mit der Schnittstelle eines Druckers ver- binden. Der fehlerfreie Betrieb ist nur mit dem entsprechenden KERN- Schnittstellen- kabel sichergestellt. Kommunikationsparameter (Baudrate, Bits und Parität) von Anzeigegerät und Dru- cker müssen übereinstimmen.
  • Page 31: Kleine Pannenhilfe

    • Die Waagenanzeige steht nicht auf Null offensichtlich falsch • Die Justierung stimmt nicht mehr. • Es herrschen starke Temperaturschwankungen. • Die Anwärmzeit wurde nicht eingehalten. • Elektromagnetische Felder / Statische Aufladung (anderen Aufstellort wählen / falls möglich, stören- des Gerät ausschalten ) KFF-T-BA_IA-d-1111...
  • Page 32: Installation Anzeigegerät / Wägebrücke

    (2%). Der gesamte Nullstellbereich beträgt also 4 % der Waa- genkapazität. Die Addition von Waagenkapazität, Vorlast und gesamten Nullstellbereich ergibt die erforderliche Kapazität der Wägezelle. Um eine Überlastung der Wägezelle zu vermeiden, sollte eine zusätzliche Sicherheitsmarge eingerechnet werden. • Kleinster gewünschte Anzeigeschritt KFF-T-BA_IA-d-1111...
  • Page 33: Plattform Anschließen

    12.3 Plattform anschließen Anschlussbox (Sender) vom Netz trennen. Die einzelnen Leitungen des Lastzellenkabels am Stecker der Anschlussbox befestigen. Die Steckerbelegung nachfolgender Abbildung entnehmen. KFF-T-BA_IA-d-1111...
  • Page 34: Anzeigegerät Konfigurieren

    Navigation im Menü lassen sich die einzelnen Menüpunkte der Reihe nach anwählen. Ausgewählten Menüpunkt mit bestätigen. Die aktuelle Einstellung wird an- gezeigt. kann in die verfügbaren Einstellungen umgeschaltet werden. Entweder mit speichern oder mit verwerfen. Zum Verlassen des Menüs wiederholt drücken. KFF-T-BA_IA-d-1111...
  • Page 35 0, 0.0, 0.00, 0.000 Ablesbarkeit wählbar 1, 2, 5, 10, 20, 50 Waagenkapazität (Max) Linearisierung, s. Kap. 6.7 Justierung, s. Kap. 6.6 Nicht dokumentiert Interner A/D-Wandler Wert Rücksetzung auf Werkseinstellung Wägemodus (Toleranzwägen, Summieren) Tierwägemodus Nicht dokumentiert Nicht dokumentiert KFF-T-BA_IA-d-1111...
  • Page 36 KERN KFF-T Version 1.1 02/2011 Operating and installation instructions Display unit Table of Contents Technical Specifications................... 4 Appliance overview ................... 5 Keyboard overview .......................6 2.1.1 Numerical input via the navigation buttons................ 7 Overview of displays.....................7 Basic Information (General) ................8 Proper use ........................8...
  • Page 37 Technical Specifications .....................29 10.2 Printer mode .......................29 10.3 Continuous data output ....................29 Instant help....................30 Installing display unit / weighing bridge............ 31 12.1 Technical Specifications .....................31 12.2 Weighing system design.....................31 12.3 How to connect the platform..................32 12.4 Configure display unit ....................33 KFF-T-BA_IA-e-1111...
  • Page 38: Technical Specifications

    1 Technical Specifications KERN KFF-T Display 6-digit Resolution 30.000 Weighing ranges Divisions 1,2,5,…10, n Weighing Units g, kg, lb, oz, tJ, hJ Display LCD 0.87 in digits with back lighting 80-100 Ω. Max. 4 item per 350 Ω; DMS weighing cells Sensitivity 2-3 mV/V Input voltage 220 V –...
  • Page 39: Appliance Overview

    2. Status of rechargeable battery 3. Weight display 4. Keyboard Back view display unit (receiver): 5. RS-232 6. Mains adapter connection 7. Table leg Connecting box (sender) 8. Antenna 9. ON/OFF switch 10. Mains adapter connection 11. Input connection Load cell cable KFF-T-BA_IA-e-1111...
  • Page 40: Keyboard Overview

    • Add weighing value to summation memory • Display sum total • Calculate weighing data via interface • Delete • Change between gross and net weight • Digit selection to the right Navigation key • Switch-over weighing unit • Back to menu/weighing mode KFF-T-BA_IA-e-1111...
  • Page 41: Numerical Input Via The Navigation Buttons

    Digit selection to the right Arrow key Terminate input 2.2 Overview of displays Display Significance Charging status of rechargeable battery STABLE Stability display ZERO Zero display GROSS Gross weight Net weight AUTO Automatic add-up enabled Adding Indicators for weighing with tolerance range KFF-T-BA_IA-e-1111...
  • Page 42: Basic Information (General)

    The display unit may only be operated in accordance with the described default settings. Other areas of use must be released by KERN in writing. 3.3 Warranty Warranty claims shall be voided in case •...
  • Page 43: Monitoring Of Test Resources

    In KERN’s accredited DKD calibration laboratory test weights and display units may be calibrated (return to the national standard) fast and at moderate cost.
  • Page 44: Unpacking And Erection

    Transmission frequency and connecting box are factory-set. 6.3 Scope of delivery / serial accessories: • Display unit, see chapter 2 • Connection box, see chapter 2 • 2 Mains power supplies • Cable screwing • Operating instructions KFF-T-BA_IA-e-1111...
  • Page 45: Mains Connection

    6.4 Mains connection Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. 6.5 Rechargeable battery operation Before the first use, the battery should be charged by connecting it to the mains power supply for at least 12 hours.
  • Page 46 After the adjustment the balance will carry out a self-test. Remove adjusting weight during selftest, the appliance will return into weighing mode automatically. An adjusting error or incorrect adjusting weight will be indicated by the error message; repeat adjustment procedure. KFF-T-BA_IA-e-1111...
  • Page 47: Linearization

    After the adjustment the balance will carry out a self-test. Remove adjusting weight during selftest, the appliance will return into weighing mode automatically. An adjusting error or incorrect adjusting weight will be indicated by the error message; repeat adjustment procedure. KFF-T-BA_IA-e-1111...
  • Page 48: Operation

    Overloading exceeding the stated maximum load (max) of the device, minus a possibly existing tare load, must be strictly avoided. This could damage the instrument. Exceeding maximum load is indicated by the display of “ol“, and an audio sound. Unload weighing system or reduce preload. KFF-T-BA_IA-e-1111...
  • Page 49: Weighing With Tare

    The taring process can be repeated any number of times, e.g. when adding several components for a mixture (adding). The limit is reached when the whole weighing range is exhausted. To change between gross weight and net weight, press To delete the tare value, remove load from weighing plate and press KFF-T-BA_IA-e-1111...
  • Page 50: Weighing Units

    To enable [off] / disable [on] the displayed weighing unit, press Acknowledge by Repeat sequence for each desired weighing unit. Press repeatedly and the device will return to weighing mode. 2. How to change weighing units To return to the previously enabled weighing units go to weighing mode by KFF-T-BA_IA-e-1111...
  • Page 51 To enter the lower limit, e. g. 1000 Kg, press the navigation keys (See chpt. 2.1.1); the currently enabled digit will be flashing. Confirm input by Select by pressing SET HI Press and the current setting for the upper limit will be displayed. KFF-T-BA_IA-e-1111...
  • Page 52: Weighing With Tolerance Range

    Put on goods to be weighed, tolerance control is started Load below specified Load within specified Load exceeds specified tolerance tolerance tolerance • The tolerance control is not active when the weight is under 20d. • To delete limits, enter “00.000 kg“. KFF-T-BA_IA-e-1111...
  • Page 53: Manual Totalizing

    Display of the saved weighing data: If you see a display of zero , press and the number of weighings, followed by the total weight will be shown for 2 sec and printed if an optional printer is connected. KFF-T-BA_IA-e-1111...
  • Page 54 „ pr 0 / Lab 0“): 1 First weighing 2 Second weighing 3 Third weighing 4 Number of weighings / total Further printed samples independent of the settings in the menu „F5 Prt“ „pr/Lab“, s. Kap. 8.2 „Tab. 1“. KFF-T-BA_IA-e-1111...
  • Page 55: Automatic Adding-Up

    You can repeat this process until the capacity of the weighing system is exhausted. • After the audio sound was sounded you can remove the load or add to it. • For how to display and delete weighing data, as well as a printout example, see chpt. 7.8. KFF-T-BA_IA-e-1111...
  • Page 56: Animal Weighing

    Whilst averaging is taking place you can add or remove loads as the measuring value will be constantly updated. To disable the animal weighing function, return to weighing mode Select menu setting , see chpt. 12.4. KFF-T-BA_IA-e-1111...
  • Page 57: Menu

    Change settings To change to the available settings, press the navigations keys as described in chpt. 2.1.1. Acknowledge setting / Either save by pressing or cancel by pressing exit the menu Return to weighing Press repeatedly to exit menu. mode KFF-T-BA_IA-e-1111...
  • Page 58: Overview

    If load is within tolerance, [ok] will be displayed bp 2 and audio signal will be sounded If the load is beyond the tolerance range, [ok] bp 3 will be shown and the audio signal will sound. KFF-T-BA_IA-e-1111...
  • Page 59 2. Baud rate The currently set baud rate (b xxx) will be shown after the RS-232 mode was confirmed. Select desired baud rate by pressing and confirm by pressing Available baud rate: 600, 1200, 2400, 4800, 9600 KFF-T-BA_IA-e-1111...
  • Page 60 4. Printer type After the data output format has been confirmed, the currently set printer type will be displayed. Mit Select the desired printer type by pressing and confirm by pressing KERN P Standard printer setting (ty-tp) LP50 Not documented Ty 711 Not documented see chpt 12.4...
  • Page 61 0.222 kg 0.222 kg TOTAL: 1.666 kg 0.666 kg GW:: 0.888 kg 0.888 kg TOTAL: 1.666 kg GS / GW Gross weight Net weight Tare weight Number weighing processes TOTAL Total of all individual weighings DATE Date TIME Time KFF-T-BA_IA-e-1111...
  • Page 62: Service, Maintenance, Disposal

    Do not use aggressive detergents (solvents or similar). 9.2 Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. Before opening, disconnect from power supply. 9.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 63: Data Output Rs 232C

    Use a suitable cable to connect the display unit to the interface of the printer. Faultless operation requires an adequate KERN interface cable. Communication parameters (baud rate, bits and parity) of display unit and printer must match.
  • Page 64: Instant Help

    • The display of the balance is not at zero obviously incorrect • Adjustment is no longer correct. • Great fluctuations in temperature. • Warm-up time was ignored. • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) KFF-T-BA_IA-e-1111...
  • Page 65: Installing Display Unit / Weighing Bridge

    4 % of the scale’s capacity. The addition of weighing scales capacity, preload and the total zero setting range give the required capacity for the weighing cell. To avoid overloading of the weighing cell, include an additional safety margin. • Smallest desired display division KFF-T-BA_IA-e-1111...
  • Page 66: How To Connect The Platform

    12.3 How to connect the platform Disconnect connecting box (sender) from mains. Attach the individual wires of the load cell cable to the plug of the connecting box. Please see diagram below for plug allocation. KFF-T-BA_IA-e-1111...
  • Page 67: Configure Display Unit

    , the individual menu items can be selected one after the other. Confirm selected menu item by pressing . The current setting will be displayed. Switch into the available settings using Either save by pressing or cancel by pressing Press repeatedly to exit menu. KFF-T-BA_IA-e-1111...
  • Page 68 1, 2, 5, 10, 20, 50 Balance capacity (max) For linearisation see chapter 6.7 Adjustment, see chapt. 6.6 Not documented Internal A/D converter value Reset to default setting Weighing mode (tolerance weighing, add-up) Animal weighing mode Not documented Not documented KFF-T-BA_IA-e-1111...
  • Page 70 KERN KFF-T Version 1.1 02/2011 Mode d’emploi et notice d’installation Afficheur Sommaire Caractéristiques techniques ................4 Aperçu de l’appareil ..................5 Vue d’ensemble du clavier ...................6 2.1.1 Saisie numérique sur les touches de navigation ............... 7 Vue d’ensemble des affichages..................7 Indications fondamentales (généralités) ............
  • Page 71 Edition des données en continu .................29 Aide succincte en cas de panne..............30 Installation Appareil d’affichage / Pont de pesée ........31 12.1 Caractéristiques techniques ..................31 12.2 Structure du système de pesée..................31 12.3 Brancher la plateforme ....................32 12.4 Configurer l‘afficheur ....................33 KFF-T-BA_IA-f-1111...
  • Page 72: Caractéristiques Techniques

    1 Caractéristiques techniques KERN KFF-T Affichage à 6 décades Résolution 30.000 Plages de pesée Echelle de chiffres 1,2,5,…10, n Unités de pesage g, kg, lb, oz, tJ, hJ Affichage LCD taille des chiffres 22 mm, éclairage d'arrière-plan 80-100 Ω. Max. 4 pièces à 350 Ω;...
  • Page 73: Aperçu De L'appareil

    Etat de l‘accu Affichage du poids Panneau à touches Vue dorsale afficheur (récepteur): RS-232 Raccord adaptateur secteur Pied de table Boîte de raccordement (émetteur) Antenne Interrupteur marche / arrêt 10. Raccord adaptateur secteur 11. Entrée branchement câble des cellules de charge KFF-T-BA_IA-f-1111...
  • Page 74: Vue D'ensemble Du Clavier

    • Rechercher les données de pesée par l’interface • Effacer • Commutation poids brut poids net Touche de navigation • Sélection des chiffres de gauche à droite • Commutation de l’unité de pesée • Retour au menu/mode de pesée KFF-T-BA_IA-f-1111...
  • Page 75: Saisie Numérique Sur Les Touches De Navigation

    2.2 Vue d’ensemble des affichages Affichage Signification Etat de chargement de l’accu STABLE Affichage de la stabilité ZERO Affichage du zéro GROSS Poids brut Poids net AUTO Totalisation automatique activée Totalisation Indicateurs pour pesage avec domaine de tolérance KFF-T-BA_IA-f-1111...
  • Page 76: Indications Fondamentales (Généralités)

    L’appareil d’affichage ne doit être utilisé que selon les consignes indiquées. Les domaines d´utilisation/d´application dérogeant à ces dernières doivent faire l´objet d´une autorisation écrite délivrée par KERN. 3.3 Garantie La garantie n´est plus valable en cas •...
  • Page 77: Vérification Des Moyens De Contrôle

    à cette opération sont disponibles sur le site KERN (www.kern-sohn.com). Grâce à son laboratoire de calibrage accrédité DKD, KERN propose un calibrage rapide et économique pour les poids de calibrage et les appareils d’affichage avec plateau de pesée branché (sur la base du standard national).
  • Page 78: Déballage Et Installation

    La fréquence émise par l’afficheur et la boîte de raccordement est réglée à l’usine. 6.3 Etendue de la livraison / accessoires de série : • Afficheur, voir chap. 2 • Boîte de raccordement, voir chap. 2 • 2 Bloc d'alimentation • Vissage des câbles • Mode d’emploi KFF-T-BA_IA-f-1111...
  • Page 79: Branchement Secteur

    L´alimentation en courant s´effectue au moyen du bloc externe d´alimentation secteur. La valeur de tension imprimée sur l´appareil doit concorder avec la tension locale. N´utilisez que des blocs d´alimentation secteur livrés par KERN. L´utilisation d´autres marques n´est possible qu´avec l´autorisation de KERN.
  • Page 80 Retirez le poids d’ajustage en cours de contrôle automatique, l’appareil revient automatiquement en mode de pesée. En cas d’erreur d’ajustage ou d’une valeur d’ajustage erronée, un message d’erreur est affiché et il faut alors recommencer le processus d’ajustage. KFF-T-BA_IA-f-1111...
  • Page 81: Atténuation Des Distorsions Non Linéaires

    Retirez le poids d’ajustage en cours de contrôle automatique, l’appareil revient automatiquement en mode de pesée. En cas d’erreur d’ajustage ou d’une valeur d’ajustage erronée, un message d’erreur est affiché et il faut alors recommencer le processus d’ajustage. KFF-T-BA_IA-f-1111...
  • Page 82: Fonctionnement

    (Max.) après déduction éventuelle d´une charge de tare déjà existante. L’appareil pourrait être endommagé. Le dépassement de la charge maximale est affiché dans l’écran „ol“ et un signal acoustique. Délester le système de pesée ou réduire la précontrainte. KFF-T-BA_IA-f-1111...
  • Page 83: Pesée Avec Tare

    , le commutateur permet de passer du poids brut au poids net et vice versa. Pour effacer la valeur de la tare, déchargez le plateau de pesée et appuyez sur . KFF-T-BA_IA-f-1111...
  • Page 84: Unités De Pesage

    Répétez ce processus pour chaque unité de pesage voulue. Répétez la pression , la balance retourne en mode de pesée 2. Commutation des unités de pesée En mode de pesée avec , il est possible de commuter dans les unités de pesée préalablement activées. KFF-T-BA_IA-f-1111...
  • Page 85: Pesée Avec Gamme De Tolérance

    , le réglage actuel est affiché. Saisissez sur les touches de navigation (voir au chap. 2.1.1) la valeur-limite inférieure p. ex. 1.000 kg, la décade respectivement active clignote. Confirmez la saisie en sélectionner SET HI Appuyez sur , la valeur-limite supérieure actuellement réglée s’affiche. KFF-T-BA_IA-f-1111...
  • Page 86 • Le contrôle de la tolérance n’est pas activé lorsque le poids se trouve en dessous de 20d. • Saisissez pour effacer les valeurs limites la valeur „00.000 kg“. KFF-T-BA_IA-f-1111...
  • Page 87: Totalisation Manuelle

    Ce procédé peut être répété tant de fois jusqu’à ce que la capacité du système de pesée soit épuisée. Affichage des données de pesée mémorisées: Appuyez sur lorsque l’affichage est sur zéro, le nombre de pesées suivi du poids total s’affiche pendant 2 sec. et est édité sur une imprimante en option. KFF-T-BA_IA-f-1111...
  • Page 88 Exemple d’édition (réglage du menu „F5 Prt“ „pr 0 / Lab 0“): 1 Première pesée 2 Deuxième pesée 3 Troisième pesée 4 Nombre de pesées/Somme totale D’autres exemples d’impression dépendants du réglage dans le menu „F5 Prt“ „pr/Lab“, voir chap. 8.2 „Tab. 1“. KFF-T-BA_IA-f-1111...
  • Page 89: Totalisation Automatique

    épuisée. • Une fois le signal sonore intervenu, aucun objet à peser ne peut plus être retiré ou ajouté. • Affichage et effacement des données de pesée, ainsi que de l’exemple d’impression voir au chap. 7.8. KFF-T-BA_IA-f-1111...
  • Page 90: Pesée D'animaux

    La valeur pondérale étant réactualisée en permanence, il est possible d’ajouter ou de retirer des objets à peser pendant l’extrapolation de la moyenne. Pour désactiver la fonction pesée du bétail/ retour en mode de pesée sélectionnez le réglage du menu , voir au chap. 12.4. KFF-T-BA_IA-f-1111...
  • Page 91: Menu

    Les touches de navigation, voir au chap. 2.1.1 permettent de commuter ve rs les réglages disponibles. Valider le réglage / Soit mémoriser sur soit rejeter sur quitter le menu Retour en mode d Pour sortir du menu enfoncer plusieurs fois la touche pesage KFF-T-BA_IA-f-1111...
  • Page 92: Aperçu

    [ok] est affiché accompagné du signal bp 2 acoustique lorsque l’objet à peser se trouve dans la gamme des tolérances. [ok] est affiché accompagné du signal bp 3 acoustique lorsque l’objet à peser se trouve en dehors de la gamme des tolérances. KFF-T-BA_IA-f-1111...
  • Page 93 2. Taux Baud Le taux de bauds actuellement réglé (b xxxx) s’affiche après validation du mode RS-232. Sur sélectionner le taux Baud désiré et confirmer sur Le taux de bauds peut être sélectionné à 600, 1200, 2400, 4800, 9600 bauds KFF-T-BA_IA-f-1111...
  • Page 94 Non documenté 4. Type d’imprimante Le type d’imprimante des données actuellement réglé est affiché après validation du format d’édition des données. sélectionner le type d’imprimante désiré et confirmer sur KERN P Réglage standard de l’imprimante (ty-tp) LP50 Non documenté Ty 711 Non documenté...
  • Page 95 0.222 kg 0.222 kg TOTAL: 1.666 kg 0.666 kg GW:: 0.888 kg 0.888 kg TOTAL: 1.666 kg GS / GW Poids brut Poids net Poids tare Nombre de pesées TOTAL Somme de toutes les pesées individuelles DATE Date TIME Heure KFF-T-BA_IA-f-1111...
  • Page 96: Maintenance, Entretien, Élimination

    Ne pas utiliser de produits de nettoyage agressifs (dissolvants ou pareil). 9.2 Maintenance, entretien L´appareil ne doit être ouvert que par des dépanneurs formés à cette fin et ayant reçu l´autorisation de KERN. Avant d´ouvrir l´appareil, couper ce dernier du secteur. 9.3 Mise au rebut L´élimination de l´emballage et de l´appareil doit être effectuée par l´utilisateur selon...
  • Page 97: Sortie De Données Rs 232C

    Relier l’afficheur avec l’interface d’une imprimante par un câble approprié. Seul un câble d’interface KERN correspondant vous assure une exploitation sans panne. Les paramètres de communication (vitesse de transmission en bauds, bits et parité) doivent coïncider entre l’afficheur et l’imprimante. Description détaillée des paramètres d’interface voir au chap.
  • Page 98: Aide Succincte En Cas De Panne

    • L´affichage de la balance n´est pas sur zéro est manifestement faux • L´ajustage n´est plus bon. • Changements élevés de température. • Le temps de préchauffage n’a pas été respecté. • Champs électromagnétiques/ charge électrostatique (changer de lieu d´installation/ si possible, arrêter l´appareil provoquant l´anomalie) KFF-T-BA_IA-f-1111...
  • Page 99: Installation Appareil D'affichage / Pont De Pesée

    De l’addition de la capacité de la balance, de la précontrainte et de toute la plage de mise à zéro résulte la capacité nécessaire de la cellule de pesée. Afin d’éviter une surcharge de la cellule de pesée, une additionnelle marge de sécurité devrait être calculée. • Plus petit pas d’affichage voulu KFF-T-BA_IA-f-1111...
  • Page 100: Brancher La Plateforme

    12.3 Brancher la plateforme Débrancher la boîte de raccordement (émetteur) du secteur. Fixer les différents conducteurs du câble des cellules de charge à la fiche de la boîte de raccordement. Voir l’affectation des fiches à la figure suivante. KFF-T-BA_IA-f-1111...
  • Page 101: Configurer L'afficheur

    être appelés successivement les différents points de menu. Valider sur le point de menu sélectionné. Le réglage actuel est affiché. peut être commuté vers les réglages disponibles. *Soit mémoriser sur soit rejeter sur Pour sortir du menu enfoncer plusieurs fois la touche KFF-T-BA_IA-f-1111...
  • Page 102 Capacité de la balance (max) Linéarisation, voir au chap. 6,7 Ajustage, voir au chap. 6.6 Non documenté Valeur interne du convertisseur analogique- digital RAZ au réglages d’usine Mode de pesée (pesée de tolérance, totalisation) Mode de pesée d’animaux Non documenté Non documenté KFF-T-BA_IA-f-1111...