  • Page 1 Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-AP Unicode/Multicode...
  • Page 2: Table Of Contents

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 Exclusion of liability and warranty ................. 6 General safety precautions ...................
  • Page 3 Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 10.6. Connector assignment of safety switch CTP-…-AP-…-SA-… with plug connector M12, 8-pin ....15 10.7. Connector assignment of safety switch CTP-…-AP-…-SII-… with plug connectors 2 x M12, 5-pin ..16 10.8. Connection of CTP-AP ........................16 10.9. Notes on operation with safe control systems .................17 10.10.
  • Page 4: About This Document

    Safety information and any available data sheet form the complete user information for your device. Important! Make sure to use the operating instructions valid for your product version. Please contact the EUCHNER support team if you have any questions.
  • Page 5: Correct Use

    EN IEC 60204-1 Ì The safety switch is allowed to be operated only in conjunction with the intended EUCHNER actuator and the related con- nection components from EUCHNER. If different actuators or other connection components are used, EUCHNER provides no warranty for safe function.
  • Page 6: Description Of The Safety Function

    Prior to use, read the operating instructions and keep these in a safe place. Ensure the operating instructions are always available during mounting, setup and servicing. For this reason you should archive a printed copy of the operating instructions. You can download the operating instructions from www.euchner.com. (translation of the original operating instructions) 2126290-08-07/24...
  • Page 7: Function

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 6. Function The device monitors the position of movable guards. Transponder-coded actuator The system consists of the following components: coded actuator (transponder) and switch. Whether the device learns the complete actuator code (unicode) or not (multi- code) depends on the respective version.
  • Page 8: Guard Locking On Version Ctp-I1

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 6.6. Guard locking on version CTP-I1 (guard locking actuated by spring force and released by power-ON) Activating guard locking: close guard; no voltage at the solenoid. Releasing guard locking: apply voltage to the solenoid. The spring-operated guard locking functions in accordance with the closed-circuit current principle.
  • Page 9: Manual Release

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 7. Manual release Important! No further release functions can be retrofitted on Extended variants with control elements in position 1 (S1) and position 2 (S2). Some situations require the guard locking to be released manually (e.g. malfunctions or an emergency). A function test should be performed after release.
  • Page 10: Emergency Release

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 7.2. Emergency release This permits opening of a locked guard from outside the danger area without tools. For mounting, see the mounting supplement. Important! It must be possible to operate the emergency release manually from outside the protected area Ì...
  • Page 11: Wire Front Release (Bowden)

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 7.4. Wire front release (bowden) Release via a pull wire. Depending on the type of attachment, the wire front release can be used as a front release or escape release. Important! The wire front release meets the requirements of Category B according Ì...
  • Page 12: Mounting

    In accordance with section 6.3 of EN ISO 14119:2014, the environmental influences (e.g. direct UV Ì radiation or corrosion) must be checked before a guard locking device is used. Contact EUCHNER if you have any questions about environmental influences or about use in aggres- Ì sive environments.
  • Page 13: Electrical Connection

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 10. Electrical connection WARNING In the event of a fault, loss of the safety function due to incorrect connection. To ensure safety, both safety outputs (FO1A and FO1B) must always be evaluated. Ì Monitoring outputs must not be used as safety outputs. Ì...
  • Page 14: Safety In Case Of Faults

    Risk of damage to equipment or malfunctions as a result of incorrect connecting cables. Use connection components and connecting cables from EUCHNER. Ì If other connection components are used, the requirements in the following table apply. EUCHNER Ì provides no warranty for safe function in case of failure to comply with these requirements.
  • Page 15: Connector Assignment Of Safety Switch Ctp

    BN/YE n.c. BN/GN n.c. Solenoid operating voltage, 0 V DC 0VUB Electronics operating voltage, 0 V DC 1) Only for standard EUCHNER connecting cable 10.6. Connector assignment of safety switch CTP-…-AP-…-SA-… with plug connector M12, 8-pin Wiring diagram C Conductor coloring Plug connector Designation...
  • Page 16: Connector Assignment Of Safety Switch Ctp

    The user is responsible for safe integration into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter the order number of your switch in the search box. You will find all available connection exam- ples for the device in Downloads.
  • Page 17: Notes On Operation With Safe Control Systems

    - Clock pulses up to a length of max. 5 ms are tolerated. A detailed example of connecting and setting the parameters of the control system is available for many devices at www.euchner.com, in the area Downloads/Applications/CTP. The features of the respective device are dealt with there in greater detail.
  • Page 18: Connection Of Guard Locking Control

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 10.10. Connection of guard locking control 10.10.1. Guard locking control for variants with IMM connection Guard locking solenoid operating voltage, 24 V DC Guard locking solenoid operating voltage, 0 V DC Fig. 5: Connection example with IMM connection 10.10.2.
  • Page 19: Setup

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 11. Setup 11.1. LED displays You will find a detailed description of the signal functions in chapter 12. System status table on page 21. Color STATE green LOCK yellow STATE LOCK 11.2. Teaching-in actuator (only for unicode evaluation) The actuator must be allocated to the safety switch using a teach-in function before the system forms a functional unit.
  • Page 20: Functional Check

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 3. Switch off operating voltage UB (min. 3 s). The code of the actuator that was just taught-in is activated in the safety switch. ¨ 4. Switch on operating voltage UB. The device operates normally. ¨...
  • Page 21: System Status Table

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 12. System status table LED indicator Output Operating mode State closed Normal operation, door closed and locked Normal operation, door closed and not locked closed Normal operation Normal operation, door open. On the version with switch-on check for the guard locking open (see chapter 6.2.
  • Page 22: Technical Data

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 13. Technical data NOTICE If a data sheet is included with the product, the information on the data sheet applies. 13.1. Technical data for safety switch CTP-AP Value Parameter Unit min. typ. max. General Material - Switch head Die-cast zinc...
  • Page 23: Typical System Times

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP Value Parameter Unit min. typ. max. Monitoring outputs OL, OI, OD p-switching, short circuit-proof Output voltage 0.8 x UB V DC Max. load Solenoid Solenoid operating voltage IMP (reverse polarity protected, DC 24 V +10%/-15% regulated, residual ripple < 5%) Solenoid current consumption I Connection rating Duty cycle...
  • Page 24: Radio Frequency Approvals

    CTP-I1-AP SERIES CTP-I2-AP SERIES CTP-IBI-AP SERIES CTP-L1-AP SERIES CTP-L2-AP SERIES CTP-LBI-AP SERIES Responsible Party – U.S. Contact Information EUCHNER USA Inc. 1860 Jarvis Avenue Elk Grove Village, Illinois 60007 +1 315 701-0315 info(at)euchner-usa.com http://www.euchner-usa.com (translation of the original operating instructions) 2126290-08-07/24...
  • Page 25: Dimension Drawing For Safety Switch Ctp

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 13.3. Dimension drawing for safety switch CTP… Version with plug connectors 2 x M12 With escape release The actuator shaft for the escape release can be extended using support brackets (max. 94 mm) ≈ 5 Basic position for escape release ∅ 5.3 (4x), 1.4 Nm 44 / 74 / 94...
  • Page 26 Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP With auxiliary key release With release, automatic return max. 50 With emergency release With wire front release (bowden) 21,5 32,4 (translation of the original operating instructions) 2126290-08-07/24...
  • Page 27: Technical Data For Actuator Ctp

    Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 13.4. Technical data for actuator CTP-... Value Parameter Unit min. typ. max. Housing material Fiber reinforced plastic Weight 0.03 … 0.06 (depending on version) Ambient temperature °C Degree of protection IP67/IP69/IP69K Mechanical life 1 x 10 Locking force F max.
  • Page 28 Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP Dimension drawing Min. door radius [mm] Order no./item 37,5 122667 A-C-H-W-SST-122667 12,45 Bent, upward 122668 A-C-H-W-SST-122668 5,25 Bent, downward max. 28 (translation of the original operating instructions) 2126290-08-07/24...
  • Page 29 Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP Dimension drawing Min. door radius [mm] Order no./item 3,25 122671 A-C-H-RL-LS-122671 max. 28 X = 53 mm (122671, 122672) X = 49 mm (122669, 122670) 122672 A-C-H-RR-LS-122672 122675 A-C-H-RO-LS-122675 max. 28 X = 41 mm (122673, 122674) X = 45 mm (122675, 122676) 13,2 X = 41 mm (122673, 122674)
  • Page 30: Ordering Information And Accessories

    17. Declaration of conformity The product complies with the requirements according to Machinery Directive 2006/42/EC. The EU declaration of conformity can be found at www.euchner.com. Enter the order number of your device in the search box. The document is available under Downloads.
  • Page 31 Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP 2126290-08-07/24 (translation of the original operating instructions)
  • Page 32 Edition: 2126290-08-07/24 Title: Operating Instructions Transponder-Coded Safety Switch CTP-I.-AP (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 07/2024 Subject to technical modifications; no responsibility is accept- ed for the accuracy of this information.