1. APPLICATION
NIPRESS D–500 series pressure transmitters with ceramic inner or optional flush diaphragm measure pressure
and convert it into voltage and current output can be used in either 2- and 3-wire systems. The D-500 series is
especially suitable for measuring aggressive, contaminated, pasty media, and low-pressure oxygen applications.
The design, the overload capacity, resistance to various temperature ranges, and the mounting options and
positions' versatility make these transmitters applicable even under the most demanding industrial conditions.
Transmitters can be delivered with plug-in display UNICONT PLK–501 enabling on-site reading. Ex or SIL
versions are also available.
2. TECHNICAL DATA
Measurement range
Overload capability
Accuracy
Process temperature
(1)
Ambient temperature
(2)
Sensor
Materials
Sensor seal
of the
wetted
Process
parts
connection
Housing
Output
Supply voltage (U
)
(2)
Supply
Load resistance
Process connection
Electrical connection
Ingress protection
Electrical protection
Weight
Permissible temperature for PVDF process connection must be between −30...+60 °C (−22...140 °F)
(1)
For information of Ex certified devices, see Special Data for Ex certified models chart
(2)
S
Ex
PECIAL DATA FOR
CERTIFIED MODELS
ATEX approval, Ex ia
Ex marking
Ex reference document
Ex Supply voltage
Intrinsically safety data
Permissible medium temperature,
atmospheric pressure
Connecting cable (in case of the device
equipped with integral cable)
2.2 O
(
RDER CODE
NOT ALL COMBINATIONS POSSIBLE
NIPRESS
Process
Measuring method
Code
connection
Gauge
R
¼" BSP
Absolute
E
½" BSP
¼" NPT
½" NPT
M20×1.5
* Ex versions are marked "Ex" right after the type designation on the label
Inner diaphragm version only
(1)
Inner or optional flush diaphragm version
(2)
Custom measuring range, based on prior negotiations
(3)
Inner diaphragm design (only with 1% accuracy)
(4)
Inner or optional flush design
(5)
Inner diaphragm design
(6)
Only with PTFE-coated version or underpressure ranges
(7)
Ex or SIL versions are available on request
(8)
Note:
In case of non-standard applications, the sensor type, sealing and housing, as well as the
requirement for filling with food compatible oil has to be specified in the order!
D–5–2, –6, –C, –D
−1...600 bar (0...8700 psi) (According to the order code)
According to the order code
±0.5%
−40...+125 °C (−40...+257 °F)
−40...+85 °C (−40...+185 °F)
(with integrated cable: −5...+70 °C [+23...+158 °F])
Ceramic
FKM (Viton
Optional: EPDM, P
≤ 160 bar (P
N
Stainless steel 1.4404 (316L)
Optional: ½" BSP, PVDF, P
Stainless steel 1.4404 (316L)
Optional: Stainless steel 1.4301 (304)
4...20 mA
8...32 V DC,
SIL version: 14...28 V DC
R
= (U
– U
)/0.02 A [Ω]
max
Supply
Supply min.
According to the order code
ISO 4400, M12×1 (4-pin), integrated cable
IP65 (ISO 4400), IP67 (M12×1), IP68 (integrated cable with ventilation tube)
Class III (SELV)
~ 0.14 kg
(
4...20 mA / 2-
ONLY FOR
In case of metal
In case of PVDF
The maximum interior capacity between the power supply connections and the metal housing is 27 nF.
!)
D
– 5
Range
Code
capability [bar]
A
–1...0
(1)
C
0...0.4
(2)
G
0...0.6
(1)
H
0...1.0
(1)
J
0...1.6
(1)
0...2.5
0...4.0
0...6.0
0...10
0...16
0...25
0...40
0...60
0...100
0...160
0...250
0...400
0...600
D–5–3
)
®
≤ 2320 psi)
N
≤ 60 bar (P
≤ 870 psi)
N
N
0...10 V
14...30 V DC
R
= 10 kΩ
min
)
WIRE
D–5–6 Ex,
:
II 1G Ex ia IIC T4 Ga,
x
process connection
:
II 2G Ex ia IIC T4 Gb,
x
process connection
drc5022a0600h_02
10...28 V DC
U
= 28 V DC, I
= 93 mA, P
imax
imax
Zone 0:
−20...+60 °C (−4...+140 °F), 0.8 bar (11.6 psi) ≤ p
Zone 1, 2:
−20...+70 °C (−4...+158 °F)
Cable capacitance: 160 pF/m
Cable inductivity: 1 µH/m
*
/ overload
(3)
Code
Accuracy
/
4
0
0.5%
(4)
/
1
3
1%
(5)
/
2
4
(5)
/
2
5
(5)
/
4
6
(5)
7
/
4
(5)
/
10
8
(5)
/
10
9
(5)
/
20
A
(5)
/
40
B
(5)
/
40
C
(5)
/
100
D
(6)
/
100
E
(6)
/
200
F
(6)
/
400
G
(6)
/
400
H
(6)
/
600
J
(6)
/
800
K
(6)
MICROWELL spol. s r. o.
SNP 2018/42, 927 00 Šaľa
Tel.: (+421) 31/ 770 7585, 770 7082
E-mail: microwell@microwell.sk
2.1 A
CCESSORIES
User's manual
Warranty Card
EU Declaration of Conformity
D–5–D Ex
II 1D Ex ia IIIC T 135°C Da
x
II 2D Ex ia IIIC T 85°C Db
x
= 660 mW, C
≈ 0 nF, L
≈ 0 µH
imax
i
i
Code
Output / Ex
2
4...20 mA, 2-wire
3
0...10 V, 3-wire
(7)
4...20 mA, 2-wire / Ex ia
4...20 mA, 2-wire, SIL 2
4...20 mA, 2-wire, SIL 2 / Ex ia
Dodávateľ:
www.microwell.sk
≤ 1.1 bar (15.9 psi)
atm
Code
2
3
6
(8)
C
(8)
D
(8)
drc502en23h03 – 1/3

Advertisement

loading
Need help?

Need help?

Do you have a question about the Nipress D- 5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for NIVELCO Nipress D- 5 Series

  • Page 1 Thank you for choosing NIVELCO instrument. 1. APPLICATION NIPRESS D–500 series pressure transmitters with ceramic inner or optional flush diaphragm measure pressure and convert it into voltage and current output can be used in either 2- and 3-wire systems. The D-500 series is especially suitable for measuring aggressive, contaminated, pasty media, and low-pressure oxygen applications.
  • Page 2 2.3 D IMENSIONS Transmitter + DC–5–2, –3, –6 DC–5–C, –D PLK–501–2 DA–5– DG–5– DH–5– Normal version SIL and SIL-Ex version Plug-in display 3. INSTALLATION Mounting steps for NPT thread connections: Use a suitable sealant (e.g. PTFE tape). Turn the device by hand to the correct Due to its small size and weight the transmitter can be directly installed on tanks, thread and tighten it with an open-end torque wrench.
  • Page 3 5. SPECIAL CONDITIONS OF SAFE USE April 2023 NIVELCO reserves the right to change technical data without notice! • Before turning on the device, make sure the installation is complete, with no defects visible. • The device may only be used within the limitations specified in the technical specifications.