• The product is only intended for use at connection
points that
a) do not exceed a maximum permissible mains im-
pedance of "Z
0,418 Ω", or
max
b) have a mains constant current carrying capacity
of at least 100 A per phase.
• As the user, you are required to ensure that the con-
nection point at which you wish to operate the prod-
uct fulfils one of the requirements mentioned, a) or
b). If necessary, consult with your energy supplier
in this regard.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
Connection type X
If the mains connection cable of this product is dam-
aged, it must be replaced by a specially prepared
mains connection cable which can be obtained from
the manufacturer or its service department.
12. Maintenance
If specialists for unusual maintenance work or re-
pairs must be involved, please always contact a
service point recommended by us or contact us
directly.
• Only perform repair, maintenance and cleaning
work as well as the correction of malfunctions with
the drive switched off as a basic rule.
• All protective and safety equipment must be reas-
sembled immediately after repair, maintenance is
completed.
Cleaning
m Attention! Pull out the mains plug.
• Clean the machine after work is complete.
• Dust and contamination must be removed from the
machine regularly.
• Keep protective devices, air vents and the motor
housing free from dust and dirt.
• Clean the device clean with a clean cloth or blow it
off with compressed air at low pressure.
• All moving parts must be re-lubricated periodically.
• Do not use any cleaning products or solvents; they
could attack the plastic parts of the device. Make
sure that no water can penetrate the device interior.
Carbon brushes
If excessive sparks are generated, have an electrician
check the carbon brushes.
Attention! The carbon brushes must only be replaced
by an electrician.
Check the oil level
The oil level must be checked before every use of the
device.
Place the device on the floor with the tool receiver fac-
ing down. The oil level must be at the cross marking.
Refill the oil if necessary.
Oil change: Fig.5
The oil must be changed after about 40-50 operating
hours.
Recommended oil: 100 ml SAE 15W/40 or comparable.
m Attention! Switch off the device. Pull out the
mains plug!
1. Lay the device on its back and unscrew the sight
glass (4) using the hexagon spanner provided (A).
2. Now empty the used oil by tipping it into a suitable
container.
Attention: The used oil must be disposed of at
the appropriate waste oil collection point!
3. Fill the new oil (approx. 100 ml) in the oil filler hole.
4. Tighten the sight glass again and check the oil lev-
el. If necessary, add oil or drain off excess oil until
the oil level is correct.
5. Check the oil level once more after a short period.
Service information
With this product, it is necessary to note that the following
parts are subject to natural or usage-related wear, or that
the following parts are required as consumables.
Wearing parts*: All chisels, carbon brushes
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
www.scheppach.com
GB | 25
Need help?
Do you have a question about the AB1700 and is the answer not in the manual?