Table 1-7. System Messages (continued)
Message
Invalid PCIe card
found in the
Internal_Storage
slot!
Keyboard
Controller
failure
Manufacturing
mode detected
Memory address
line failure at
address , read
value expecting
value
Memory double
word logic
failure at
address , read
value expecting
value
Memory odd/even
logic failure at
address, read
value expecting
value
Memory
write/read
failure at
address , read
value expecting
value
Memory tests
terminated by
keystroke.
38
About Your System
Causes
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.
Faulty keyboard controller;
faulty system board
System is in manufacturing
mode.
Faulty or improperly installed
memory modules.
POST memory test
terminated by pressing the
spacebar.
Corrective Actions
Remove the PCIe expansion
card and install either the
internal SAS controller in the
dedicated slot.
See "Getting Help" on
page 175.
Reboot to take the system
out of manufacturing mode.
See "Troubleshooting System
Memory" on page 150.
Information only.