Dell PowerEdge E06S Series Hardware Owner's Manual page 45

Dell server hardware owner's manual
Table of Contents

Advertisement

Message
Current boot mode
is set to UEFI.
Please ensure
compatible
bootable media is
available. Use
the system setup
program to change
the boot mode as
needed.
Embedded NIC x and
NIC y :
OS NIC= <ENABLED
|DISABLED> ,
Management
Shared NIC=
<ENABLED
|DISABLED>
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Gate A20 failure Faulty keyboard controller;
General failure
Causes
The system failed to boot
because UEFI boot mode is
enabled in BIOS and the
boot operating system is non-
UEFI.
The operating system NIC
interface is set in BIOS. The
Management Shared NIC
interface is set in
management tools.
Mouse or keyboard cable is
loose or improperly
connected.
Defective mouse or keyboard. Ensure that the mouse or
faulty system board.
The operating system is
unable to carry out the
command.
Corrective Actions
Ensure that the boot mode is
set correctly and that the
proper bootable media is
available. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 63.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC" on
page 175.
Reseat the mouse or
keyboard cable.
keyboard is operational. See
"Troubleshooting a USB
Device" on page 174.
See "Getting Help" on
page 203.
This message is usually
followed by specific
information. Note the
information, and take the
appropriate action to resolve
the problem.
About Your System
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e06s001Poweredge r910External oemr r910

Table of Contents