Dell PowerEdge E06S Series Hardware Owner's Manual page 35

Dell server hardware owner's manual
Table of Contents

Advertisement

Code
Text
E1A15 SAS cable B
failure.
Check
connection.
E1A1D Control panel
USB cable not
detected.
Check cable.
E2010 Memory not
detected.
Inspect
DIMMs.
E2011 Memory
configuratio
n failure.
Check DIMMs.
E2012 Memory
configured
but unusable.
Check DIMMs.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
Causes
SAS cable B is missing or
bad.
USB cable to the control
panel is missing or bad.
No memory was detected in
the system.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
Memory configured, but is
unusable.
The system BIOS failed to
copy its flash image into
memory.
Corrective Actions
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 203
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 203.
Install memory or reseat
the memory risers and
memory modules. See
"Installing a Memory
Riser" on page 101,
"Installing Memory
Modules" on page 102 or
"Troubleshooting System
Memory" on page 181.
See "Troubleshooting
System Memory" on
page 181.
See "Troubleshooting
System Memory" on
page 181.
See "Troubleshooting
System Memory" on
page 181.
About Your System