Code
Text
E1631 System power
draw exceeded
threshold.
Contact
support.
E1632 PowerSafe
event.
Contact
support.
E1710 I/O channel
check error.
Review &
clear SEL.
E1711 PCI parity
error on Bus
## Device ##
Function ##.
PCI parity
error on Slot
#. Review &
clear SEL.
Causes
The processors and memory
throttling is not sufficient to
keep system power
consumption below the
maximum safe level with
current power supply
configuration.
The processors and memory
have been throttled to keep
system power consumption
below the maximum safe
level with current power
supply configuration.
The system BIOS reported
an I/O channel check.
The system BIOS reported a
PCI parity error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
The system BIOS reported a
PCI parity error on a
component that resides in
the specified slot.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 203.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 189.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 189.
About Your System
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e06s001Poweredge r910External oemr r910

Table of Contents