Dell PowerEdge E06S Series Hardware Owner's Manual page 38

Dell server hardware owner's manual
Table of Contents

Advertisement

Code
Text
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
E2022 General
failure
during POST.
Check screen
message.
E2025 QPI
initializati
on error.
Contact
support.
E2026 Memory
initializati
on error.
Contact
support.
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
38
About Your System
Causes
Incorrect memory
configuration.
General failure after video.
QuickPath Interconnect
(QPI) failure.
Invalid memory
configuration.
The memory module in slot
"##" has had a multi-bit
error (MBE).
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log any more SBEs until
the system is rebooted. "##"
represents the memory
module implicated by the
BIOS.
Corrective Actions
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 181.
Check screen for specific
error messages.
See "Getting Help" on
page 203.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines"
on page 92. See "Getting
Help" on page 203.
See "Troubleshooting
System Memory" on
page 181.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 181.

Hide quick links: