Installing The Backplane; Control Panel (Optional); Removing The Control Panel - Dell PowerEdge C1100 Hardware Owner's Manual

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge C1100:
Table of Contents

Advertisement

Installing the Backplane

1 Insert the backplane in the direction of the arrow until it is seated in the
system.
2 Replace all the hard drives in the system. See "Installing a Hard-Drive
Carrier" on page 52.
3 Replace the cooling fan assembly and secure with the two screws.
4 Connect all cooling fan power cables.
5 Connect the SATA cables, the IPMB cable, and a single power cable.
See Figure 5-4.
6 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 55.
7 Replace the system cover. See "Closing the System" on page 54.
8 Reconnect the system and peripherals to their electrical outlets,
and turn on the system.

Control Panel (Optional)

Removing the Control Panel

CAUTION:
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.
1 Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2 Remove the single securing screw from the side of the chassis.
See Figure 3-23.
3 Pull the control panel out of the chassis. See Figure 3-23.
88
Installing System Components
Many repairs may only be done by a certified service technician.