Mx003 Series Scanner Interface Pin Assignments - Metrologic MS6130 Installation And User Manual

Hand held laser scanner and scanner interface
Table of Contents

Advertisement

A
C
PPENDIX

MX003 Series Scanner Interface Pin Assignments

The interfaces are equipped with a shielded, 10-pin modular jack
manufactured by Steward Stamping. The mating connector is a Steward
Stamping shielded plug #937-SP-361010. Caution should be used when
working with cables for this port because there is typically power present for
scanner interface operation.
Models MX003, MX0033 and MX0034:
Pin
1
2
3
4
5
6
7
8
9
10
Models MX003-17, MX0033-17 and MX0034-17:
Pin
1
2
3
4
5
6
7
8
9
10
36
Function
Power (d/c)/Shield Ground
RS-232 Transmit Output
RS-232 Receiver Input
RTS Output
CTS Input
DTR Input
LP/DATA
NC
+5Vdc Power to Scanner Interface
NC
Function
Power (d/c)/Shield Ground
RS-232 Transmit Output
RS-232 Receiver Input
Keyboard Data
Keyboard Clock
PC Clock
PC Data
NC
PC +5V/ External +5V
NC