Nicd Battery Charger With Reconditioning Feature - Metrologic MS6130 Installation And User Manual

Hand held laser scanner and scanner interface
Table of Contents

Advertisement

N
C
B
I
D
ATTERY
MLPN: 45561 - 115V and 45562 - 230V
Transformer
Red LED
(Power)
Figure 7: Reconditioning
R
ECOMMENDED
To maintain charge capacity, the NiCd batteries must be discharged fully
before charging. We call this process reconditioning.
Recondition if:
The batteries were not used within 20 days
The batteries were not discharged (approximately two hours of
continuous operation) at least once a week
Low battery indicators:
Both LED's on the scanner blink
The scanner quietly beeps twice while scanning
Recondition once a week if:
The batteries do not get discharged for more than 20%
(approximately ½ hour) of their capacity before recharging.
Recondition once every two weeks if:
The batteries do not get discharged for more than 50%
(approximately 1 hour) of their capacity before recharging.
Note: The day to day usage of the NiCd batteries will determine the
frequency of the discharges (reconditioning).
Charge State
Battery Absent
Charge Pending
Discharge-Before-
Charge
Fast-Charge
Charge Complete Top-
Off
C
HARGER WITH
Discharge
Cycle Switch
Green LED
(Charge Status)
U
SE
R
ECONDITIONING
How to Recondition
1. Place the scanner into the
charge stand.
2. Push the stand tilt cup in
the extreme down position
to expose the hole for the
discharge cycle switch.
3. Use a pin to push the
discharge cycle switch
located beneath the hole.
4. When the discharge mode
is initiated the green LED
flashes.
CHG LED Status
LED off
LED on for 0.125sec, off for
1.375sec
LED on for 1.375sec, off for
0.125sec
LED on
LED on for 0.125 sec, off for
0.125sec
F
EATURE
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx003

Table of Contents