Metrologic MS6130 Installation And User Manual

Hand held laser scanner and scanner interface

Advertisement

Quick Links

METROLOGIC INSTRUMENTS, INC.
MS6130 Hand Held Laser Scanner
and MX003 Scanner Interfaces
Installation and User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Metrologic MS6130

  • Page 1 METROLOGIC INSTRUMENTS, INC. MS6130 Hand Held Laser Scanner and MX003 Scanner Interfaces Installation and User’s Guide...
  • Page 3 Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid Italy Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO) France Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX...
  • Page 4: Table Of Contents

    Enabling the MS700i/MS720i Scanner’s RF Low Speed Option ... 16 Changing the ID... 17 Matching Procedure... 18 Parts of the MS6130 Hand-Held Bar Code Scanner... 19 Components of the MS6130 Series Stand... 20 Installation of the MS6130 Series Stand... 21 Installation of the 6000 Series Universal Charging Stand...
  • Page 5 Maintenance ... 27 Troubleshooting ... 28 Appendix A Specifications... 29 Appendix B Default Settings of the MS6130 and “MX” Interface ... 32 Appendix C MX003 Series Scanner Interface Pin Assignments ... 36 Appendix D Warranty and Disclaimer... 37 Appendix E Notices...
  • Page 7: Ms6130 Hand Held Bar Code Scanner

    30 feet from the receiver. When not in use, the scanner rests in a universal-charging stand. The scanner will be fully charged in 2 hours when not scanning in the stand. A fully charged MS6130 can provide up to 8 hours of wireless, hand-held scanning. After dormant periods, the scanner is programmed to enter a timeout mode that will extend the battery life.
  • Page 8: Mx003 Series Scanner Interfaces

    Metrologic’s MX003 Series Scanner Interfaces provide a short range, one- way wireless data communication link between a remote portable scanner and an RS-232 or light pen host device. Specifically, Metrologic’s MS6130 Hand-Held Laser Scanners include a Liberty Metrologic’s MS700i/MS720i series scanners, TECH series scanners may be connected to a MX Series scanner interface.
  • Page 9: Unpacking List

    NPACKING Your shipment will contain a set of items from the two groups listed below: Transmitter Group: MS6130 Hand-Held Scanner Stand #45880 (optional) Stand #45558, 45559 and 45560 (optional) MS4120 Programming Guide Receiver Group: “MX” Scanner Interface MCA951 adapter or adapter cable (if required)
  • Page 10: Connections Of The "Mx" Interface To The Host Device

    AC outlet. The socket outlet should be near the equipment and easily accessible. Plug the transformer into the side of the MCA and the AC outlet. Power up the host system. MS6130 with Liberty Scanner Interface (Transmitter) “MX” Scanner Interface Figure 2: Connecting the “MX”...
  • Page 11: Connections Of The Keyboard Wedge "Mx" Interface To The Pc

    “MX” I NTERFACE TO THE Version 17 only MX003 Scanner Interfaces with a suffix of “17" are Keyboard Wedge versions used to interface with a PC and keyboard. Turn off the PC. Plug the “MX” receiver adapter cable to the PC keyboard port.
  • Page 12: Connections Of The Ms700I/Ms720I With "Mx" To The Host Device

    ONNECTIONS OF THE “MX” WITH TO THE To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. Turn off the host system. Connect the 25-pin D-type connector on the MS700i/MS720i scanner’s head cable to the communication cable.
  • Page 13: Configuration Of The Ms700I/Ms720I With "Mx

    Once the transmitter is assigned an ID number, configure the S700i/MS720i to accept RF communication. Although the changes made in this section effect the receiver, the MS6130 performs all scanning. Scan the following bar code to enter the receiver’s program mode.
  • Page 14: Configuration Of The Ms700I/Ms720I With "Mx" To The Host System

    Note: When the Load Defaults bar code in the ScanSelect Scanner Programming Guide is chosen, it will automatically disable the RF low speed option. For the MS6130 to communicate to the MS700i/MS720i scanner, re-enable the RF Low Speed Option (refer to the procedure above).
  • Page 15: Configuration Of The "Mx" To The Scanpal ® Data Collector

    The RS-232 parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the MS6130 and “MX” Receiver section of this guide. To communicate with each other properly, the “MX” and ScanPal must have matching RS-232 parameters.
  • Page 16: Host System

    Mode bar code in the MS4120 Programming Guide will not cause your “MX” to enter or exit program mode. Scan the Enter/Exit Program Mode for the Receiver bar code in the following procedure. Once the MS6130 is assigned an ID number, configure the “MX” to the correct communication protocol.
  • Page 17: Keyboard Wedge (Kb) Interface

    EYBOARD EDGE Scan the ENABLE KB WEDGE INTERFACE bar code if your communication requirement is keyboard emulation. The scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. Enable Keyboard Wedge Interface KB Parameter - Keyboard Type The following bar codes are used to define the type of keyboard in use.
  • Page 18 EYBOARD EDGE KB Parameter – Keyboard Type The following bar codes are used to define the keyboard country type. If necessary, scan the appropriate bar code. IBM KB4700 Financial Keyboard (KB) I NTERFACE ** USA Keyboard UK Keyboard France Keyboard Germany Keyboard Italy Keyboard Spain Keyboard...
  • Page 19 EDGE KB Parameter - Caps Lock Mode When Caps Lock is used on the keyboard, choose ENABLE CAPS LOCK. Once enabled, the scanner will simulate Caps Lock keyboard input. This mode will not work with all keyboard types. To detect automatically if Caps Lock is used, enable AUTO-DETECTION CAPS LOCK MODE.
  • Page 20 EYBOARD EDGE KB Parameter - Alt Mode When this option is enabled, the scanner will duplicate this keyboard sequence: Hold down the Alt key; type the decimal number that corresponds to the appropriate keyboard character. Caution should be observed when...
  • Page 21: Configuration Of The Ms6130 Hand-Held

    MS4120 Programming Guide, the Disable ITF bar code, then the Enter/Exit Program Mode bar code again. Note: When the MS6130 is in program mode, never scan any of the RS-232 or light pen options marked with an “R”. The list of options is in the Default Settings of the Transmitter and “MX”...
  • Page 22: Enabling The Ms700I/Ms720I Scanner's Rf Low Speed Option

    Before beginning this procedure, perform all steps in the sections, Matching the Transmitter to the Receiver and Configuration of the MS700i/MS720i with “MX”. Use the MS700i/MS720i scanner to scan the following bar codes. Temporarily cover the bar code below Step 3. Scan the following bar code to enter program mode.
  • Page 23: Changing The Id

    HANGING THE In order for the MS6130 to send data to the correct receiver, they must have a matching ID number. The ID number is the serial number of the receiver. When the matching procedure is completed, the receiver will accept data only from a MS6130 that has the matching ID number.
  • Page 24: Matching Procedure

    ATCHING ROCEDURE With the MS6130, scan the following bar codes starting from the top down: Transmitter Enter/Exit Program Mode Transmitter Enter/Exit Program Mode Locate the model label on the case of the receiver. Scan the serial number bar code. The receiver and MS6130 are now matched.
  • Page 25: Parts Of The Ms6130 Hand-Held Bar Code Scanner

    MS6130 H ARTS OF THE Becoming familiar with the features of the MS6130 hand-held scanner will help when operating one of these scanners. The illustration and list explain the pertinent parts. Output Window Infra-red (IR) Sensor Battery Charge Contacts Reactivation Switch...
  • Page 26: Components Of The Ms6130 Series Stand

    OMPONENTS OF THE The following are the components used to build the MS6130 series stand (MLPN: 45880). Cradle Stand Charger Pack Pole Cover Flex pole Stand Base Cover Stand Base Charger Transformer Charger Pack Screws Mounting Screws 10. Lock Washer...
  • Page 27: Installation Of The Ms6130 Series Stand

    Stand LED Indicators (with the scanner in the stand) No LED indicates trickle charge and the green LED indicates fast charge. To change from trickle charge to fast charge, simply lift the scanner from the stand and replace. Note: When both scanner LEDs blink, it is an indication of a low battery.
  • Page 28: Installation Of The 6000 Series Universal Charging Stand

    NSTALLATION OF THE MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK) Transformer Figure 6: Universal Charging Stand ERMANENT OUNTER Separate weighted base from rotating base by removing the (4) four screws. Use the rotating base as a drill template. Use the (4) four wood screws provided to mount the base to the counter top securely.
  • Page 29: Nicd Battery Charger With Reconditioning Feature

    Low battery indicators: Both LED’s on the scanner blink The scanner quietly beeps twice while scanning Recondition once a week if: The batteries do not get discharged for more than 20% (approximately ½ hour) of their capacity before recharging.
  • Page 30: Visual Indicators

    If the unit has been dormant for longer than 10 minutes, reactivating the unit by pressing the button on the side of the MS6130 will be necessary. When the scanner first receives power, the steady red LED will flash, followed by the green LED.
  • Page 31: Audible Indicators

    If the scanner successfully reads a bar code, the green light will flash. If the “MX” receiver successfully receives the data from the MS6130, the “MX” will beep once. Razzberry Tone If, upon power up, the scanner emits a razzberry tone, then the scanner has failed diagnostics.
  • Page 32 UDIBLE NDICATORS The “MX” receiver can be programmed to emit three beeps when the timeout occurs during communication between the host and receiver. Refer to the MS4120 Programming Guide section, Audible Indicators for Communication Timeouts to program this feature. There are four settings available for the tone of the beep for the receiver. Refer to the MS4120 Programming Guide section, Beeper Tones to program the feature to change the tone or turn the beeper off.
  • Page 33: Labels

    ABELS The MS6130 scanner is either a CDRH Class II laser system or an IEC Class 1 Laser System. Your unit will have a CDRH Class II caution label or LASERKLASSE 1 label affixed below the model number label. The model number/avoid exposure label is located on the bottom of the scanner’s head.
  • Page 34: Troubleshooting

    ROUBLESHOOTING The receiver can receive data from a MS6130 with its own ID or 10 zeroes. It’s own ID can be received all the time. When using 10 zeroes, the first scan the receiver gets must have 10 zeroes as its ID and from that point on the receiver will accept both ID’s.
  • Page 35: Specifications

    PPENDIX Specifications RF Link Characteristics Frequencies: Bandwidth: Modulation: Certification: RF Protocol: Operating Range: Specifications subject to change without notice MS6130 Bar Code Scanner Specifications UL Listed: FCC ID: RF Output Power: Current: Antenna: Dimensions: Length Width Height Weight: Maximum Radiant Power:...
  • Page 36 A (C PPENDIX ONTINUED MX003 Series Scanner Interface Specifications FCC ID: Operating Voltage: Antenna: Dimensions: Weight: UL Listed: Model Number Frequency MX003 MX003-17 MX0033 MX0033-17 MX0034 MX0034-17 Model designation may include the suffix “J” used to indicate the addition of an audio signal output jack.
  • Page 37 Storage (Long): -30 to +35 UK Compliance To charge the batteries in the MS6130 - 418MHz, remove the ESD cover from the bottom of the unit. Refer to the battery charge rate for additional information. After a full charge, replace the cover over the battery contacts.
  • Page 38: Default Settings Of The Ms6130 And "Mx" Interface

    If an asterisk is not in the default column then the default setting is Off or Disabled. The MS6130 and “MX” receiver do not support every parameter. For those parameters that are a transmitter function, a letter “T” will appear in the second column of the charts, for the “MX”, the...
  • Page 39 B (C PPENDIX ONTINUED Parameter Long Range Activation in the Stand Normal Scan Pulsing Scan Custom Scan Green LED Rescan Indicator Short Same Symbol Rescan Long Same Symbol Rescan Alternate Beeper Tone 1 Alternate Beeper Tone 2 Alternate Beeper Tone 3 No Beeper Tone Two Second Time-out No Two Second Timeout...
  • Page 40 B (C PPENDIX ONTINUED Parameter DTR Input Carriage Return Line Feed ETX Suffix Tab Prefix Tab Suffix Prefix ID for UPC/EAN Suffix ID for UPC/EAN Bars High Spaces High Transmit as Scanned Transmit as Code 39 Poll Light Pen 5 Volts No Poll Light Pen Code 39 Codabar...
  • Page 41 Transmit Cleanup Bit Transmit Alt Mode Transmit 0F0H Break Character Inter Scan Code Delay 800 msec 7.5 msec 15 msec Intercharacter Delay 1 msec 10 msec 100 msec Stand Alone Scanner Mode T - TRANSMITTER DEFAULT R - RECEIVER KEYBOARD WEDGE...
  • Page 42: Mx003 Series Scanner Interface Pin Assignments

    PPENDIX MX003 Series Scanner Interface Pin Assignments The interfaces are equipped with a shielded, 10-pin modular jack manufactured by Steward Stamping. The mating connector is a Steward Stamping shielded plug #937-SP-361010. Caution should be used when working with cables for this port because there is typically power present for scanner interface operation.
  • Page 43: Warranty And Disclaimer

    Limited Warranty The MS6130 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS6130 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS6130 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
  • Page 44: Notices

    Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device.
  • Page 45: Patents

    PPENDIX Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,930,848; 4,958,984; 5,081,342; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,591,953; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,808,285; 5,811,786; 5,825,012; 5,886,337; 5,925,870; 5,925,871;...
  • Page 46: Index

    List Locations 4, 6 Low speed options Maintenance Matching procedure MCA95 Model number 32-35 MS6130 MS700i/MS720i “MX” 2-10, 15, 16, 25, 26, 28, 32 NiCd battery charger Notices Output window Parts Patents Programming guide 7, 9, 10, 17, 18, 28...
  • Page 47 NDEX ONTINUED Receiver board Red LED 1, 19, 24, 25 Rights property RS-232 ® ScanPal ScanSelect Shipping carton South America Specifications Stand Temperature Tones Transformer 4, 6, 20, 21 Transmitter 1-3, 7, 10, 15, 16, 18, 29, 32-35 Troubleshooting Unpacking list USA corporate headquarters Visual indicators Voltage...
  • Page 48 March 2002 Printed in the USA 0 0 - 0 2 2 1 2...

This manual is also suitable for:

Mx003

Table of Contents