SPECIFICATIONS
Specifications are approximate and subject to change without notice. Amps and wattage
vary according to the operating load. Refer to the nameplate of the pump for the performance data. Image shown is an example
only. Do not exceed the given specifications in the use of your pump, or use for purposes for which the pump is not designed. It is
the users responsibility to ensure that the product is suitable for the intended application.
INTENDED USE
This pump is to be installed in a suitable water reservoir of suitable depth for the purpose of providing a fountain and/or assisting
with oxygenation of the water.
PERFORMANCE CURVE
Refer to the nameplate of the pump then search our website
WARNING:
MANDATORY INSTALLATION CONDITION: THE PREMISES WHERE THE PUMP IS INSTALLED
MUST BE PROTECTED BY A SAFETY SWITCH (RCD) – DO NOT INSTALL PUMPS WITHOUT THIS PROTECTION
DANGER:
Keep the pump equipment protected from interference by children or pets! The appliance is not intended for use
by children or infirm or incompetent persons.
WARNING:
This pump is designed for water only. It must NOT be used for Hazardous or flammable liquids. It must NOT be
used in locations classified as hazardous. It is not for use in aquaculture, or similar applications.
LIMITATIONS:
This pump is suitable to pump fresh water only, with soft particles of a size as designated on the data sheet for that
model. Refer to the nameplate of the pump then search our website
pumps are not intended for pumping potable water, and have not been tested for pumping potable water. They are not intended
for fire-fighting. The water temperature may be from + 5°C to the maximum as stated on the pumps nameplate.
DANGER: DO NOT install in bodies of water used for swimming or bathing.
WARNING: The pump cannot be used for salt water and flammable, corrosive, explosive or
dangerous liquids, nor in hazardous areas. Ensure that the pump never runs without
water.
1 |
P a g e
A S C E N T O G R O U P A U S T R A L I A 3 7 E x p o r t S t r e e t L y t t o n Q L D 4 1 7 8
P : 1 8 0 0 8 0 7 6 0 4
www.reefe.com.au
www.reefe.com.au
E :
s a l e s @ a s c e n t o . c o m . a u
for the current tech data sheet.
for the current tech data sheet. These
V e r s i o n :
2 0 2 0 0 9 0 9
Need help?
Do you have a question about the RFA Series and is the answer not in the manual?
Questions and answers