Download Print this page
Assa Abloy Norton Unitrol UNI J8300 Installation Instructions
Assa Abloy Norton Unitrol UNI J8300 Installation Instructions

Assa Abloy Norton Unitrol UNI J8300 Installation Instructions

Stop/holder

Advertisement

Quick Links

Unitrol
The closing force for these series door
closers is adjustable from a size 1 to a size 6,
as outlined in ANSI Standard A156.4. When
these series of door closers are installed and
adjusted to conform to ADA reduced opening
force requirements (5 lbs max.) for interior
doors, they may not have adequate closing
force to reliably close and latch the door. Power adjustments
charted on Page 4 are recommended where possible, to
ensure proper door control.
Always use template covering door-opening-angle desired,
correct door-thickness and frame-reveal, and door-hanging-
hardware being used. Template dimensions in these
instructions (page 2) cover frame reveals to 7-3/8" (187mm)
in opening with 1-3/4" (44mm) thick doors hung on 4-1/2"
(114mm) wide template-hinges (figure 2), 3/4" (19mm)
offset-pivots (figure 2) or center-pivots (figure 3).
Check hand of door: right or left (see figure 5, page 3).
Make sure that door opens the full angle desired and latches
without any binding action or interference. Note that hold-
open units will require that door swing five (5) degrees past
hold-open point, to dead-stop position.
It is suggested that sex-nuts and bolts be used to mount
arm-foot and to mount closer to flush partitions.
Top Jamb Unitrols are supplied with arm rod units according
to frame-reveal. An arm number is stamped on the arm
rods, as shown on Figures 2 and 3 (page 2).
Components:
Power
Adjustment
Shaft
8500 Series
Standard Plastic
with Cover Screws
Cover with Insert
Installation Instructions
80-9380-2214-020 Rev 3 (05-24)
Non Hold Open
UNI J8300
UNI J8301
Series No.*
UNI J8500
UNI J8501
* These series have a DELAYED ACTION CLOSING option available that
is identified with a "DA" suffix to the series number.
damage or personal injury. These instructions
Optional
8300 Series Standard
Full Metal Cover
Narrow Plastic Cover
8500M Series
Approved 2024-05-14
Hold Open
UNI J8300H
UNI J8301H
UNI J8500H
UNI J8501H
CAUTION
An incorrectly installed or improperly
adjusted door closer can cause property
should be followed to avoid the possibility
of misapplication or misadjustment.
Power Adjustment Chart for
DOOR
Interior
Door
Exterior
Door
NOTE: Maximum of 20 turns (360°) of Power Adjustment Shaft.
Closer is shipped set at 10 turns.
2 Sex-nuts
Slide unit
Holder Control
Optional Architectural
w/ 1639 Pinion Cap
UNI Stop/Holder
Sizing
2, 3, 4, 5 or 6
Multi-Size 1 thru 6
2, 3, 4, 5 or 6
Multi-Size 1 thru 6
Power Adjust
+
Use 5/16" Socket or Adjustable Wrench
for this Adjustment
-
J8301(H) / J8501(H) ONLY
Number of Turns Required
MAXIMUM DOOR SIZE
32"
36"
(0.85M)
(0.90M)
4
7
7
8
Rod Unit
(Arm Number Stamp)
Main Arm
Screw
Rod Screws
Metal Cover
8500MA Series
42"
48"
(1.00M)
(1.20M)
8
9
10
12
Optional
Thru-Bolt
&
Grommet Nuts
Optional
Architectural Plastic
Full Cover w/ Insert
8500A Series

Advertisement

loading
Need help?

Need help?

Do you have a question about the Norton Unitrol UNI J8300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Assa Abloy Norton Unitrol UNI J8300

  • Page 1 Installation Instructions UNI Stop/Holder 80-9380-2214-020 Rev 3 (05-24) Unitrol Non Hold Open Hold Open Sizing UNI J8300 UNI J8300H 2, 3, 4, 5 or 6 UNI J8301 UNI J8301H Multi-Size 1 thru 6 Series No.* UNI J8500 UNI J8500H 2, 3, 4, 5 or 6 UNI J8501 UNI J8501H Multi-Size 1 thru 6...
  • Page 2 Top-Jamb Installation Template Figure 1 4 Holes For Drop Plate Application Only C L Closer Pinion (304.8) 5/16 (102) (102) (25) (19.1) (13) Reveal 3-1/4 4-1/8 (82.6) (104.8) 1-1/8 Without Drop Plate * Frame Rabbet (29) Frame Stop With Drop Plate * (76) C L Hinge or Pivot * Always use frame or transom rabbet as...
  • Page 3 Installation Sequence Set average-power of multi-size closer. (Series UNI Mount drop plate, (if used) and closer. Closer power   J8301, UNI J8501 ONLY) See Power Adjust chart on adjustment shaft toward lock edge. Page 1.  Disassemble rod-unit from arm-assembly and install See Figure 2 or 3 and select template dimensions.
  • Page 4 “on” or hold-open “off” and to adjust the hold- open force ... use screwdriver as illustrated. Copyright © 2005, 2008, 2024, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights ASSA ABLOY reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc.

This manual is also suitable for:

Norton unitrol uni j8301Norton unitrol uni j8500Norton unitrol uni j8501Norton unitrol uni j8300hNorton unitrol uni j8301hNorton unitrol uni j8500h ... Show all