Teledyne FLIR IIS Forge 5GigE Installation Manual
Teledyne FLIR IIS Forge 5GigE Installation Manual

Teledyne FLIR IIS Forge 5GigE Installation Manual

Industrial machine vision cameras
Table of Contents

Advertisement

Quick Links

Installation Guide
12/12/2024
©2015-2024 FLIR Integrated Imaging Solutions Inc. All rights reserved.
FORGE® 5GIGE
INDUSTRIAL MACHINE VISION CAMERAS
TELEDYNE FLIR IIS
Version 4.1
Revised
12/12/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLIR IIS Forge 5GigE and is the answer not in the manual?

Questions and answers

Summary of Contents for Teledyne FLIR IIS Forge 5GigE

  • Page 1 Installation Guide TELEDYNE FLIR IIS FORGE® 5GIGE INDUSTRIAL MACHINE VISION CAMERAS Version 4.1 Revised 12/12/2024 12/12/2024 ©2015-2024 FLIR Integrated Imaging Solutions Inc. All rights reserved.
  • Page 2 For more detailed information about recycling of this product, please contact us. Trademarks Names and marks appearing on the products herein are either registered trademarks or trademarks of Teledyne FLIR, LLC and/or its subsidiaries. Licensing To view the licenses of open source packages used in this product please see...
  • Page 3: Table Of Contents

    6.3 Data Interface Connector 6.3.1 Ethernet Connector 6.4 Data Interface Cables 6.5 General Purpose Input/Output (GPIO) 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 4 7.4 Output Timing Characteristics 8 Troubleshooting 8.1 Support 8.2 Status Indicator LED Contacting Teledyne FLIR IIS Revision History 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 5: Forge 5Gige Camera Installation Guide

    These resources as well as knowledge base articles and application notes can be found on the Support page for the product. Forge 5GigE Camera Resources and Support 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 6: Handling Precautions And Camera Care

    Terms and Conditions on our website. Your Teledyne FLIR IIS machine vision camera is a precisely manufactured device and should be handled with care. Here are some tips on how to care for the device. Avoid electrostatic charging. When handling the camera unit, avoid touching the lenses. Fingerprints will affect the quality of the image produced by the device.
  • Page 7: Forge 5Gige Camera Installation

    Lens Mounting) Tripod adapter (optional) (see Mounting your Forge 5GigE Camera) Teledyne FLIR IIS sells a number of the additional parts required for installation. Visit the Teledyne FLIR IIS Accessories page. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc.
  • Page 8: Installing Your Interface Card And Software

    After download is complete, open the file to start the Spinnaker setup wizard. e. Follow the steps in each setup dialog. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 9: Installing Your Forge 5Gige Camera

    3 Forge 5GigE Camera Installation 3. Optimize the settings of your Ethernet card a. In StartÒTeledyne Spinnaker SDKÒSpinView, right click on the Network Adapter and select Adapter Configuration. The Adapter Config Utility lists your network adapters and allows you to access the following:...
  • Page 10: Powering Your Forge 5Gige Camera

    When the camera is power cycled (power disengaged then re-engaged), the camera reverts to its default factory settings, or if applicable, a saved user set. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 11: Tools To Control Your Forge 5Gige Camera

    Spinnaker API examples are provided for C, C++, C#, and VB.NET languages. These examples are precompiled for your convenience. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 12: Using Genicam Applications

    Getting Started with Matrox Design Assistant Getting Started with NI-MAX and LabVIEW Getting Started with NI Vision Builder for Automatic Inspection 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 13: Configuring The Forge 5Gige Camera Setup

    Alternatively, SpinView is a tool included with the Spinnaker SDK that allows you to set the internet protocol (IP) configuration for any GigE interface cards or Teledyne FLIR IIS GigE Vision cameras connected to your system. Using SpinView, you can: Set the IP address for the current connection.
  • Page 14: Allocating Bandwidth

    Once you have calculated your required bandwidth, you can allocate an amount to each camera by adjusting the Device Throughput Limit. Allocating a specific amount to each camera helps to avoid dropped packets due to a data burst. You 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc.
  • Page 15: Configuring Other Ethernet Settings

    To control Heartbeat Timeout use: 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 16 To disable Heartbeat use: GenICam—Under Transport Layer Control GevGVCPHeartbeatDisable. Spinnaker API—The Spinnaker SDK supports disabling heartbeat. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 17: Forge 5Gige Camera Firmware

    Firmware is programming that is inserted into the programmable read-only memory (programmable ROM) of most Teledyne FLIR IIS cameras. Firmware is created and tested like software. When ready, it can be distributed like other software and installed in the programmable read-only memory by the user.
  • Page 18 5 Configuring the Forge 5GigE Camera Setup Warning! Do not disconnect the camera during the firmware update process. Related Knowledge Base Articles Teledyne FLIR machine vision software and firmware version numbering systems Determining my camera's firmware version Should I upgrade my camera firmware or software? 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions...
  • Page 19: Forge 5Gige Camera Physical Interface

    Contains camera information such as model Data Interface Connector name, serial number and required compliance. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 20: Forge 5Gige Camera Dimensions

    Forge 5GigE Camera Dimensional Drawing Barrel Length "A" Models (+0.1/-0.3) FG-P5G-50S4 FG-P5G-51S4 FG-P5G-120S6 FG-P5G-161S7 FG-P5G-244S8 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 21: Data Interface Connector

    To use PoE, an Ethernet power injector or a powered Ethernet switch must be connected to the camera. The PoE conforms to the IEEE 802.3af-2003 standard. Data Interface Cables To purchase a recommended cable from Teledyne FLIR IIS, visit the AccessoriesàCables page.
  • Page 22 Note: Also on the Advanced tab, if not already set, Jumbo Packet should be configured to 9014 Bytes. How to Optimize GigE Network Adapter Settings for more information on configuring for best performance. To purchase a compatible card from Teledyne FLIR IIS, visit the AccessoriesàHost Adapter Cards page. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions...
  • Page 23: Mounting Your Forge 5Gige Camera

    Camera Temperature and Heat Dissipation You must provide sufficient heat dissipation to control the internal operating temperature of the camera. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 24: Lens Mounting

    Make sure the camera has enough open space around it to facilitate the free flow of air. Lens Mounting Lenses are not included with cameras. Teledyne FLIR IIS sells a number of lenses compatible with our cameras from our Accessories àLenses page.
  • Page 25: Dust Protection

    The properties of this filter are illustrated in the results below. IR filter transmittance graph 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 26 Removing the IR filter alters the optical path of the camera, and may result in problems obtaining proper focus with your lens. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 27: 6.13 Sensor Shutter Type

    Readout time for a line is equal to 1/Horizontal Line Frequency. Some advantages of global shutter are more uniform brightness and minimal motion blur. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc.
  • Page 28: Input/Output Control

    The camera is equipped with a 6-pin GPIO connector on the back of the case. The connector is a Hirose HR10A-7R-6PB, the mating connector is a Hirose HR10A-7P-6S(73). 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc.
  • Page 29 2—Dual function pin 3—Open drain output, requires pullup resistor 4—Output low level depends on the output voltage / pullup resistor combination 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 30: Gpio Electrical Characteristics

    0.98 V 11.93 V 4.5 mA 24 V 4.7 KΩ 0.75 V 23.75 V 4.9 mA 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 31 Note: Parts designators in the schematics shown below are for reference only. Opto-isolated input/output circuit Non-isolated input/output circuit 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 32: Input Timing Characteristics

    Propagation Delay (High to Low) tPDHL 4.01 µS Propagation Delay (Low to High) tPDLH 25.29 µS 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.
  • Page 33 Camera’s top case temperature during measurements was ~55°C Values are for reference only. They could vary depending on the test conditions. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 34: Output Timing Characteristics

    Camera’s top case temperature during measurements was ~55°C Values are for reference only. They could vary depending on the test conditions 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 35 Measured Pulse Width from FPGA = 500.1 uS Values are for reference only. They could vary depending on the test conditions. 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does...
  • Page 36: Troubleshooting

    8 Troubleshooting Troubleshooting Support Teledyne FLIR IIS endeavors to provide the highest level of technical support possible to you. Most support resources can be accessed through your product's Support page. Forge 5GigE Camera Resources and Support Contacting Technical Support Before contacting Technical Support, have you: 1.
  • Page 37: Contacting Teledyne Flir Iis

    July 5, 2024 Support for FG-P5G-120S6 and FG-P5G-161S7 December 12, 2024 Fixed link to CAD drawings 12/12/2024 Teledyne FLIR IIS Forge 5GigE Camera ©2015-2024 FLIR Integrated Imaging Solutions Installation Guide Inc. All rights reserved. This document does not contain export-controlled information.

Table of Contents