Water Chiller
Date: Nov. 2023
Version: Ver.B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIC-A-EB and is the answer not in the manual?

Questions and answers

Summary of Contents for Shini SIC-A-EB

  • Page 1 SIC-A-EB Budget Air-cooled Water Chiller Date: Nov. 2023 Version: Ver.B...
  • Page 2: Table Of Contents

    Contents General Description ..................5 1.1 Coding Principle ..................6 1.2 Features ....................6 1.3 Technical Specifications ................. 8 1.3.1 External Dimensions ..............8 1.3.2 Specification List................8 1.4 Safety Regulations ................10 1.4.1 Security Labels ................10 1.4.2 Signs and Labels ................ 10 1.5 Exemption Clause .................
  • Page 3 6.3.1 About the Machine..............33 6.3.2 Check after Installation ............... 33 6.3.3 Daily Checking ................33 6.3.4 Weekly Checking ................ 33 6.3.5 Montly Checking ................. 33 6.3.6 Trimonthly Checking ..............33 6.3.7 Half-yearly Checking ..............33 6.3.8 Yearly Checking ................. 34 6.3.9 3 year Checking .................
  • Page 4 Picture 6-2: Fill in the Refrigerant (2) ..............31 Picture 6-3: Water Drainage Port ..............32 4(34)
  • Page 5: General Description

    Please read through this operation manual before using and installation to avoid damage of the machine and personal injuries. SIC-A-EB series are applicable for cooling molds to reduce products molding cycle, also they are available in the cooling of equipments in order to maintain a normal temperature.
  • Page 6: Coding Principle

    1.1 Coding Principle 1.2 Features 1) Cooling range 7~25℃. 2) Stainless steel insulated water tank, with prolonged service life and free of contanmination. 3) Adopt R410A refrigerant with good refrigeration effect. 4) Refrigerating system adopts multiple precise controls that accurately control the system stability.
  • Page 7 Chapter 7, which contains service instructions intended for service engineers. Other chapters contain instructions for the daily operator. Any modifications of the machine must be approved by SHINI in order to avoid personal injury and damage to machine. We shall not be liable for any damage caused by unauthorized change of the machine.
  • Page 8: Technical Specifications

    1.3 Technical Specifications 1.3.1 External Dimensions Picture 1-2: Outline Dimensional Drawing Table 1-1: Specifications Weight Chilled Chilled Water Water Water Model Water Water Tank Tank Tank (mm) (mm) (mm) (kg) Inlet Outlet Outfall Overfall Refill Port (inch) (inch) (inch) (inch) (inch) SIC-5A-EB 1265...
  • Page 9 R410 Type Evaporator Type Tube style Type Fin style Condenser Blower 0.19x2 0.25x2 0.8*2 power(kW) Water tank capacity(L) 0.37 0.75 Power (kWw) Water Pump flow(L/min) pump(50HZ) Working pressure (kgf/cm²) Total power (kw) 3.65 7.05 16.4 Chilled water 1" 1.5" outlet Pipe 1"...
  • Page 10: Safety Regulations

    Safety Regulations The user must conform to the following safety rules when operating the machine. 1.4.1 Security Labels Attention! Installation of the device is allowed only to the professional electrician. Before maintaining and repairing the device, be sure to turn off the main switch and control switch.
  • Page 11: Exemption Clause

    Shini (including employees and agents). Shini is exempted from liability for any costs, fees, claims and losses caused by reasons below: 1. Any careless or man-made installations, operation and maintenances upon machines without referring to the Manual prior to machine using.
  • Page 12 3. Any operational actions that are not authorized by Shini upon machine, including adding or replacing accessories, dismantling, delivering or repairing. 4. Employing consumables or oil media that are not appointed by Shini.
  • Page 13: Structural Features And Working Principle

    2. Structural Features and Working Principle 2.1 Main Functions SIC-A-EB Budget Air-cooled Water Chiller is constituted by 4 parts: compressor, condenser, capillaries and tube evaporator. It adopts the single-stage vapour compression refrigeration system and obtains the rifregirating effect by refrigerant gas-liquid transformation and heat absorption and release principle.
  • Page 14: Main Parts And Functions

    1) Compressing and conveying the refrigeration steam and forming low pressure in evaporator and high pressure in condenser, the compressor is the core of the whole system. 2) SIC-A-EB adopts scroll compressor. Picture 2-2: Compressor 2.1.2.2 Condensor 1) Condenser is a heat output device which is used to discharge the heat absorbed by the evaporator and converted by the compressor to the cooling medium.
  • Page 15 2) The size of the filter is usually chosen according to the caliber of the cooling agent pipe. Picture 2-4: Drying Filter 2.1.2.4 Capilliary or Thermal Expansion Value 1) The capilliary or the thermal expansion valve throttles the refrigerant and reduces the pressure of it, as well as regulate the refrigerant flow which enters the evaporator.
  • Page 16 Picture 2-6: Evaporator 2.1.2.6 High and Low Pressure Controller 1) The high and low pressure controller is used to check the working pressure of the compressor's inlet and outlet. 2) The high-pressure controller is set to 37bar, and the low-pressure controller is set to 4bar.
  • Page 17: Installation And Debugging

    3. Installation and Debugging Attention! Read this chapter before installation. Install the machine according to following steps! Air-cooled water chiller should be installed in an environment that has good ventilation, such as draughty area near the window. Ambient temperature should not be more than 43℃...
  • Page 18: Schematic Drawing Of Installation

    modification. Attention! Before connecting the machine with power supply, please make sure that main switch is turned off! 3.2 Schematic Drawing of Installation 1) Install the pipe system according to the installation and wiring diagram. Use heat insulating material to achieve heat preservation of chilled water pipe. 2) The pipe diameter of circulation pump should be no less than condenser adapter tube.
  • Page 19 Parts Name : 1. Water chiller 2. Chilled water outlet 3. Chilled water inlet 4. Water drainage port 5. Water refill port 6. Cooling water tower 7. Cooling water pump 8. Cooling water circulation 9. Chilled water circulation 10. Mould Cooling 11.
  • Page 20: Application And Operation

    Application and Operation Control Panel Picture 4-1: Control Panel Table 4-1: Specification of Control Panel Name Functions Remarks Note: Don’t try to disassemble any After powering on, switch on the main unit or touch any terminal after Power indicator power switch, the indicator will on. powering on, otherwise it may cause electric shock.
  • Page 21 Check if the motor is stuck or if the bearings are damaged. If the motor works normally, then check whether the set current of the When the pump current is too large, thermal overload relay inside the Pump overload this light will be on and make the control box is set too low again.
  • Page 22: Machine Startup

    Machine startup 1) Turn on the main switch. Picture 4-2: Stepup Step 2) Turn on the pump. Noets: a) When the operation pressure is lower than the values in the table above, the motor of the pump may be damaged because of large water flow. b) When the operation pressure is higher than the vaues in the table above, the water flow may be insufficient and the machine may need a pump replacement to ensure high pressure.
  • Page 23: Machine Shutdown

    the machine with correct methods. Attention! Anti-freezing switch and high/low pressure controller have been set in the factory, which forbids random adjustment without the company’s permission. Otherwise, we are not liable for the responsibility of any machine damage. Attention! The compressor can't be started frequently because of its characteristics (Frequent start will shorten its service life.).
  • Page 24: Temperature Setting Method

    Picture 4-1:Temperature Controller 4.4.1 Temperature Setting Method 1) Press the set button for 3 secs., and the screen will show a number that indicates current temperature set value. 2) Use the power or cold defrost key to modify the set temperature value, which has been limited to 7~25 ℃...
  • Page 25 Enable Low temp. alarm [AL][Ad] Enable High temp. alarm [AH][Ad] Disable Equipment parameter error Disable Running parameter error Stop defrosting based Disable [dP][dt][d4][A8] timeout Disable Defrost running [d6=0] Disable Condenser dirt warning [A4=10] Enable Condenser dirt alarming [A4=10] Disable Clock alarm If the clock is enabled 25(34)
  • Page 26: Trouble-Shooting

    Trouble-shooting The action of the Faults The possible fault analysis Solutions protection units A. The power supply is not switched on A. Power on after checking 1. No power B. The fuse wire of the control loop B. Check the protection loop supply display The protection units is burned out...
  • Page 27 valve is too big D. Discharge some of the refrigerant D. The packed weight of the refrigerant is excessive A. The heat degree of the A. Adjust the open scale of the expansion refrigerant in the air return pipe 8. Compressor The protection units valve properly is too high...
  • Page 28: Maintenance And Repair

    Maintenance and Repair 28(34)
  • Page 29 Attention! All repair work should be done by qualified personnel only to avoid damage to the machine or personnel injury. 29(34)
  • Page 30: Fill In The Refrigerant

    In order to operate the machine rightly and safely, please caution the matter follows: 1) Do not turn off the main power switch to stop the machine, except emergency situation. 2) When failures set in and the machine stop work with buzzer sound, first turn off the main power switch of the machine (alarm indicator will die), then go to check the reason of the failures, do not force the machine on before remove the failures.
  • Page 31: Components Maintenance

    6.2 Components Maintenance 6.2.1 Condenser SIC-A-EB series water chiller use the air cooled fin style condenser which installed openly, in the using time, it is hard to avoid any dust and sundries, which will influence the heat emission effect, so it is necessary to clean the condenser at fixed periods in order to keep its working performance.
  • Page 32: Evaporator

    Attention! Do the cleaning work every half-year in the environment with little dust, but you must do the work every month in the environment with a great deal of dusts, and under the severe environment you had better see the situation to do the work.
  • Page 33: Maintenance Schedule

    6.3 Maintenance Schedule 6.3.1 About the Machine Model Production date Ф Voltage V Frequency Total power 6.3.2 Check after Installation Check the pipes are all correctly connected. Check if there are leakages in the piping system. Check if there are breaks in welding joint. Electrical Installation Voltage: Fuse specification: 1 Phase...
  • Page 34 Check and clean the condenser and evaporator. Check and clean the filter and expansion valve. Check system performance. Clean condenser. 6.3.8 Yearly Checking Check whether the contactor is normal. 6.3.9 3 year Checking PC board renewal. No fuse breaker renewal. 34(34)