Content SAFETY REQUIREMENTS INTRODUCTION PACKING LIST MAIN TECHNICAL PARAMETERS DESIGN AND OPERATION INSTALLATION DRAWING OPERATION MODES VENTILATOR INSTALLATION FUNCTION DESCRIPTION REMOTE CONTROLLER PAIRING SYNCHRONIZATION FUNCTION MASTER UNIT SETTINGS SLAVE UNIT SETTINGS MASTER AND SLAVE UNITS RESET AND CANCELLATION IOT NETWORKING FEATURES IOT NETWORKING OPERATION STEPS MAINTENANCE STORAGE AND TRANSPORTATION RULES...
WARNING! DO NOT! recovery ventilator AV-TTW5-W. SG-ERV-150. • It’s suggested to install the ventilator more • Installation and operation of the ventilator than 2.1 m above the floor. shall be performed in accordance with •...
Ventilator 1 pc INTRODUCTION Accessories bag 1 pc Remote controller 1 pc This user’s manual includes technical description operation, installation and mounting guidelines, technical data for the heat recovery ventilator AV-TTW5-W. SG-ERV-150. User’s manual 1 pc Packing box 1 pc...
Instruction Manual Instruction Manual MAIN TECHNICAL PARAMETERS Description Unit Value Voltage 100-240 • The ventilator is designed for indoor application with an ambient temperature ranging from Frequency 50/60 -20°C (-4°F) to +50°C (+122°F) and relative humidity below 80%. Input Power 6/7/7.8 Current 0.04/0.05/0.06...
Instruction Manual Instruction Manual INSTALLATION DRAWING OPERATION MODES Ventilation Mode. The ventilator runs in exhaust or supply mode at a set speed. When synchronous operation of two connected ventilators, one runs in the supply mode and the other in exhaust mode. Rain shield housing Rain shield housing Regeneration Mode.
Instruction Manual Instruction Manual VENTILATOR INSTALLATION 1. Drill a 170 mm round hole in the wall. The hole size is shown below. Step 1: Drill a 160~170 mm round hole in the wall. The hole diameter is 160~170mm. Step 2: Put the PVC pipe into the wall. Adjust it to fit the wall then use PU Indoor Outdoor...
Page 8
Instruction Manual Instruction Manual 2. Pull the mobile bracket into the outer duct Note: Just slightly pull the duct back into place so that the silicone ring if it is stuck in the wall. Connect the power cable on the back 1.The duct is divided into two outer ducts, adaptable to the wall thickness of 50cm, Pull the duct further in if on the outside of the outer duct is tight...
Instruction Manual Instruction Manual 7. Install the main unit on the indoor surface wall, and connect the adapter wire from the back FUNCTION DESCRIPTION of the main unit to the wiring of the fan and temperature sensor exposed by the inner duct Status Light (RGB-LED) in the wall.
Instruction Manual Instruction Manual PAIRING SYNCHRONIZATION FUNCTION Fan Speed Indicator Light ON/OFF Working Mode Fan Boost Mode The suggested maximum distance is 15 meters Mode Negative Ion ON/OFF Button cell CR2025 Filter Reset Cover ON/OFF Master Unit Slave Unit Remote Control Please put in the button cell (prepared by user) before using the controller Remote Controller...
Instruction Manual Instruction Manual Slave Unit Settings 1. Connect the device to power. In the OFF state, as sho re, long press the mode button of the device for 5 seconds, and the status indicator green ligh owly. At this Master Unit Settings time, the device enters the master-slave linkage mode, the unit is set to the slave role.
Page 12
IOT NETWORKING FUNCTIONS Humidity Version SG-ERV-150 (Optional) Version ERV name. The app can connect multiple devices. Each device will have a di erent name, and user can change the device name freely.
IOT NETWORKING OPERATION STEPS WIFI RESET AND CANCELLATION SG-ERV-150 SG-ERV-150 Remove the device from the app as follows: 1. Before enabling Lot networking operation, 5.
Instruction Manual Instruction Manual MAINTENANCE Fan Maintenance (Once Per Year). Remov xed bracket in the inner duct and take out the fan. After unplugging the connecting wires of the main unit and the inner duct, remove the Clean the impeller blades. Use a soft brush, doth, or a vacuum cleaner to clean the impeller. Do main unit and the inner duct from the wall not use water abrasive detergents, solvents, or sharp objects.
Instruction Manual for the user and the quali ed installer TROUBLESHOOTING Fault Possible reasons Troubleshooting Make sure that the ventilator is properly No power supply. connected to the power and make any corrections, if necessary. The fan does not Start up. Turn the ventilator o .