Specifications of KONICA MINOLTA RANGE7
Measuring method
Triangulation by light sectioning method
Light source
Semiconductor laser, Wavelength: 660 nm
Laser class
Class 2 (IEC 60825-1 Edition 2)
Number of pixels taken
1.31 megapixels (1280 x 1024)
Measurement distance
450 to 800 mm
Receiving lens
TELE, WIDE
(interchangeable)
Distance
TELE
Measure-
450 mm
Direction
ment
range
X × Y
79×99
(mm)
Z
54
XY direction
0.08
measurement interval
Accuracy (Distance
±40μm
between balls)*
1
Precision (Z, σ)*
4μm
2
Auto-focus
Provided
Auto-exposure
Provided
Scan time
Approx. 2 sec. or more (1 scan)
Preview function
Approx. 0.4 sec./scan
Scanning ambient
500 lx or less
lighting condition
Output interface
USB 2.0 High Speed
Included AC Adapter
Power
Input voltage: 100 to 240 VAC (50/60 Hz), Rating: 1.4 A (at 100 VAC input)
Dimensions
295 (W) x 190 (H) x 200 (D) mm (Excluding grips and lens)
Weight
Approx. 6.7 kg
Operating tempera-
10 to 40°C; Relative humidity 65% or less (no condensation)
ture/humidity range
S t o r a g e t e m p e r a -
-10 to 50°C; Relative humidity 85% or less
ture/humidity range
(at 35°C, no condensation)
*1 When measuring the distance between balls for a ball bar (two balls) as defined in VDI/VDE 2634-2 under Konica
Minolta Sensing measurement conditions.
Konica Minolta Sensing measurement conditions: Temperature: 20±1°C; Lens: TELE; Measurement distance: 450
mm; Warm-up: 20 min.; Software used: Konica Minolta processing software; After calibration of the instrument;
Measurement target: Konica Minolta standard target (2 balls); Arrangement of measurement target: Konica Minolta
standard arrangement (10 positions inside measurement space); Uncertainty of standard target not included.
*2 Measurement conditions: Temperature: 20±1°C; Lens: TELE; Measurement distance: 450 mm; Warm-up: 20 min.; Mea-
surement target: Konica Minolta standard planar chart; Software used: Konica Minolta processing software; 1 σ value
*3 Using Konica Minolta processing software
Specifications of 3D Data Processing Software RANGE VIEWER
<Major Functions>
Readable data formats
Readable data
Konica Minolta proprietary formats: .rgv (Single-scan data group), .rvm
formats
(more than one piece of data)
STL (binary), ASCII point group
Data output
Konica Minolta proprietary formats: .rgv, .rvm
M e a sur e m e nt
Monitor image, Preview, AF/AE, Measurement
functions
Control of rotating stage (Konica Minolta optional accessory)
E d i t i n g f u n c -
Data alignment, Data merging (integration), Point group deletion
tions
Drawing
Point group shading
SAFETY PRECAUTIONS
Read all safety and operating instructions before operating
the KONICA MINOLTA RANGE7.
Use only a power source of the specified rating.
Improper connection may cause a fire or electric shock.
Do not stare into the laser beam.
(MAX. 34mW 660nm , CLASS 2 (IEC) LASER PRODUCT)
Konica Minolta Sensing Americas, Inc.
Konica Minolta Sensing Europe B.V.
Konica Minolta (CHINA) Investment Ltd.
Konica Minolta Sensing Singapore Pte Ltd.
Addresses and telephone/fax numbers are subject to change without notice. For the latest contact information,
please refer to the KONICA MINOLTA SENSING Worldwide Offices web page .
©2008 KONICA MINOLTA SENSING,INC.
TELE
WIDE
WIDE
800 mm
450 mm
800 mm
141×176
150×188
267×334
97
109
194
0.14
0.16
0.28
Osaka, Japan
EMail : 3dsales@konicaminolta.jp
New Jersey , U.S.A.
Phone: 888-473-2656 (in USA), 201-236-4300 (outside USA)
EMail : vivid3d@se.konicaminolta.us
German Office
München, Germany
EMail : info.germany@seu.konicaminolta.eu
French Office
Roissy CDG, France
EMail : info.france@seu.konicaminolta.eu
UK Office
Milton Keynes, United Kingdom
EMail : info.uk@seu.konicaminolta.eu
Italian Office
Milan, Italy
EMail : info.italy@seu.konicaminolta.eu
Polish Office
Wroclaw, Poland
EMail : info.poland@seu.konicaminolta.eu
SE Sales Division
Shanghai, China
Singapore

System configuration

Standard accessories
Optional accessories
AC Adapter
Calibration Chart
RA-A105
Calibration Sheet
Calibration Base
RA-A107
RA-A106
USB Cable
(5m) RA-A101
: Europe only (3m)
Platform Set for Tripod
RA-A151
Measuring Stand
Tripod
Dolly
Rotating Stage Kit (3 kg)
Rotating Stage Kit (20 kg)
Specifications and appearance shown herein subject to change without notice.
Company names and product names used herein are trademarks or registered trademarks of their respective com-
panies.
Screens shown are for illustration purpose only.
<Operating Environment>
OS
Windows® Vista 64-bit (x64)
CPU
Core2Duo, Xeon or higher
RAM
4 GB or more
Display
Graphics display capability of 1280 x 1024 or more
OpenGL compatible board (Konica Minolta verified compatible board recom-
Graphics board
mended)
Interface
USB 2.0 port
34mW
Web : http://konicaminolta.com/instruments
Web : http://se.konicaminolta.us/3d
Phone: +49 (0) 89 630267-9700
Web : http://www.konicaminolta.eu
Phone : +33(0)1 493-82519
Web : http://www.konicaminolta.eu
Phone : +44(0)1908 540-622
Web : http://www.konicaminolta.eu
Phone : +39 02 390111
Web : http://www.konicaminolta.eu
Phone : +48 71 734 52 11
Web : http://www.konicaminolta.eu
Phone: +86-021-5489 0202
Phone: +65 6563-5533
http://www.konicaminolta.com/instruments/about/network
Interchangeable
KONICA MINOLTA
Objective Lens
RANGE7
(TELE, WIDE)
Marker Sheet Trial Pack
RA-A104
(Sheets T and W, 10 for each)
3D Data Processing Software
RANGE VIEWER
Personal
Computer
(commercial product)
Reverse engineering/
testing software
Marker Sheet T
Platform Set for
RA-A205
Measuring Stand
(50 markers x 10 sheets)
RA-A201
Marker Sheet W
RA-A206
(50 markers x 10 sheets)
Storage Case
RA-A209
Registration No. : YKA 0937154
Registration No. : JQA-E-80027
Registration date : March 3, 1995
Registration date : March 12, 1997
Fax: 201-785-2482
Fax: +49 (0) 89 630267-9799
Fax: +33(0)1 493-84771
Fax: +44(0)1908 540-629
Fax: +39 02 39011.223
Fax: +48 71 734 52 10
Fax: +86-021-5489 0005
Fax: +65 6560-9721
9242-4892-50 AIEAPK 1

Advertisement

loading